Assembly and operating instructions

Read the instructions prior to performing any task! REMKO fresh water station EFS 35/EFS 50 Instructions for users and specialists 0062-2017-09 Edition 2, en_GB ...

Installation and operating instructions (translation of the orig-

inal) Read these operating instructions carefully before commis- sioning / using this device! These instructions are an integral part of the system and must always be kept near or on the device. Subject to modifications; No liability accepted for errors or mis- prints! ...

Table of contents

1 Safety and usage instructions............................................................................................................. 4 1.1 General safety notes....................................................................................................................... 4 1.2 Identification of notes.......................... ...

1.1 General safety notes

Carefully read the operating manual before com- missioning the units for the first time. It contains useful tips and notes such as hazard warnings to prevent personal injury and material damage. Failure to follow the directions in this manual not only presents a danger to people, the environment and th ...

1.6 Safety instructions for the oper-

ator The operational safety of the units and compo- nents is only assured providing they are used as intended and in a fully assembled state. n The units and components may only be set up, installed and maintained by qualified per- sonnel. n The existing regulations concerning accident prevention must be adhered to. n Do ...

1.9 Intended use

The fresh water module is only permitted to be installed in heating systems between the buffer tank and the domestic water circuit. Depending on the design, it may only be installed and operated vertically! Use only REMKO accessories in conjunction with the fresh water module. Any different or additional use is a non-intended use. The manufa ...

2.1 Unit data

Series EFS 35 EFS 50 Operating data Maximum permitted pressure, primary bar 3 Maximum permitted pressure, secon- dary bar 10 Operating temperature °C 2-95 Pipe connections Primary circuit (tank circuit) Inches 1 1/2" OT 2" OT Secondary circuit (domestic water cir- cuit) Inches 1" OT 1 1/4" OT Equipment Gravity brake mmWS 2 x 2 ...

Flow meter technical data

Series FlowSonic Dimensions Height mm 125 Top connection Inches 1" IT (DN20) Bottom connection Inches 1" IT (DN20) Hydraulics Measuring range l/min 1-100 Maximum permissible temperature °C 100 (medium) Maximum permissible pressure bar 16 (max. pressure surges 25 bar) Usable medium Water (potable) Cvs value 8 Flow measurement Accura ...

2.2 Pressure loss characteristic curves

A B C Grundfos UPM2 15-75 CIL Grundfos UPM2 25-75 1 2 EFS 35 Fig. 1: Pressure loss characteristic curve EFS 35 A: Pressure [mWS] B: Medium flow rate [m3/h] C: Pressure [kPa] 1: Secondary/2: Primary A B C EFS 50 1 2 Fig. 2: Pressure loss characteristic curve EFS 50 A: Pressure [mWS] B: Medium flow rate [m3/h] C: Pressur ...

The fresh water station is a pre-installed valve

group that was checked for leak tightness; it is used to transfer heat between the buffer tank and the domestic water circuit. It contains a pre-set controller and important valves for operating the system: n Ball valves in the primary circuit n Piston valves in the secondary circuit n Safet ...