Parker Hi-drive Quick Installation Manual
Read Online
Read the Parker Hi-drive Quick Installation Manual online using the built-in PDF viewer.
Key Pages of Document
quick installation guide Hi-drive Page 2 of 12 IMPORTANT INFORMATION The product Hi-drive, described in this handbook, doesn’t contain accessible parts to the customer, to open it or to try to approach the inner components could cause an irreparable fault. Some internal circuits are subject to voltages that could create serious hazards for people and even be lethal. It is prohibited to approach and/or to violate ...
quick installation guide Hi-drive Page 3 of 12 1.1 Hardware specifications Description Symbol UdM Type of drive Hi-Drive type 2 5 8 16 25 POWER Mains supply: three-phase or single-phase or D.C. Three-phase rated voltage Vmains V~ 200 – 10% � 480 +10% Single-phase rated voltage Vmains V~ 200 – 10% � 277 +10% D.C. Vdc V= 245 � 744 Frequency of the A.C. supply fmains Hz 50…60 ±5% Load installed for conti ...
quick installation guide Hi-drive Page 4 of 12 2.2 Assembly Do not install in hazardous environments. The rear supporting plate features special reamed holes (see illustration). • FIT IN VERTICAL POSITION (power terminal board at top). • To ensure drive cooling, leave a free space above, below and in front of at least 100 mm. The illustration shows how hot air cooling must be done in an external environment, t ...
quick installation guide Hi-drive Page 5 of 12 3 WIRING CONNECTIONS • Wire up the panel/drive/motor in accordance with the instructions in the operator's manual and applicable safety regulations. In case of any doubts, contact our After-Sales Service. • Check the correct dimensioning of the drive/motor. Compare the rated voltages and currents. • Make sure the maximum power voltage to terminals L1, L2, L3 doe ...
quick installation guide Hi-drive Page 6 of 12 3.3 Connector layout (*) The yellow and green LEDs are active if, when the drive supply is connected (24Vdc), the drive electronics is operating. The red LED, called “STATUS” provides a series of information on the state of the converter: - off the converter is disabled without active alarms. - on the converter is enabled: the drive is in RUN mode - flashing with ...
quick installation guide Hi-drive Page 7 of 12 X5 : terminal connection 0VQ drive supply 15 1 – SR drive enabling +24V drive supply 16 2 + SR drive enabling 17 3 SC B 18 4 SC A 19 5 N.C. GND (DIGITAL) 20 6 0VA OUT 1 21 7 MON 2 OUT 0 22 8 MON 1 VCC (DIGITAL) 23 9 0VA GND IN 24 10 – AX IN 3 (ENCODER IN) 25 11 + AX IN 2 (ENCODER IN) 26 12 0VA IN 1 27 13 – REF IN 0 28 14 + REF X6 : “resolver” (DB9 female ...
quick installation guide Hi-drive Page 8 of 12 In the case of D.C. current supply, the maximum voltage must be 744V=. The connection terminals are in terminal board X1 between the terminals RP (positive) and RN (negative). Direct connection to D.C. mains (three-phase) Connection for D.C. current 6 MOTOR Before entering the motor data parameter Pr31 must be defined: write “0” for brushless motor (default) ...
quick installation guide Hi-drive Page 9 of 12 8 FEEDBACK ( FBK ) Types: -FBK A, resolver only (only read if also selected as speed loop feedback). -FBK B, with the Pr62, the following systems can be selected: FBK B Pr62 INPUT ON Encoder Sincos + EnDat interface 0 X7 Encoder Sincos 1 X7 Encoder Less Wiring (**) 2 X7 5V Line Driver 422 quadrature signals (incremental encoder) (**) 3 X7 5V Line Driver 422 frequenc ...
quick installation guide Hi-drive Page 10 of 12 10 FIRST CONVERTER START-UP The drive is supplied from the factory with default programming. Remember that the Hi-drive can control brushless synchronous or asynchronous motors. Before entering the motor data, programme Pr31: write “0” for brushless motor (default condition), “1” for asynchronous motor. At this point the mechanism must be set with the fundame ...
quick installation guide Hi-drive Page 11 of 12 12 Alarms Pr23 Alarm Remedies 0 No alarm 1 Overvoltage Check the three-phase power line. Check the braking line and braking resistance Check the application 2 Undervoltage Check the three-phase power line. 3 Overcurrent Check any mechanical impediments and correct motor size for required use. Check motor connections and any short-circuits between phase-phase and phas ...
Related Devices for Parker Hi-drive:
HMR Series Positioners MANUAL NO. 109-0523-01 REV F EFFECTIVE: August 3, 2020 SUPERCEDES: December 13, 2018 Assembly and Operating Instructions Operation guide for the Parker HMR Series Valve Positioners. The manual provides technical details on regulatory notices, setup, hardware setup.
Parker Automation Manual No. 102-5871-01 Rev. D 401/402/403XE Series Product Manual Effective: October 3, 2018 Supersedes: May 18, 2018 Electromechanical Posi Official product manual for the Parker 401XE Series Valve Positioners. This guide presents device operation tips, power management, operating guidelines, operating instructions.
P33 Safety Exhaust Valve Integration Guide FRL-SIF-120_EU Instructions for safe usage of the Parker P33 Control Unit. This guide includes detailed instructions for performance guidelines, service instructions, hardware setup.
Bulletin MSG11-5715-728/UK Proportional Pressure Reducing Valve / Proportional DC Valve Brief Operation Manual Series D1FV*EE (Design series 13) D1FB*EE (Desig Operating manual for the Parker D1FV EE Series Control Unit. The manual provides information on operational guidelines, operational safety, setup instructions, service contacts.
2 0 0 5 N E W P R O D U C T S PARKER GUITARS | A REVOLUTION IN PRECISION AND SOUND Complete user documentation for the Parker Fly Guitar. This manual offers stepwise instructions for device features, maintenance procedures, operation, detailing setup.
650G Frame 1, 2, 3 & C - F HA501008U001 Issue 3 Product Manual aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics Complete technical documentation for the Parker 650G series Controller. This documentation guides on daily usage, service contacts, safety.
MA3 Hydraulic Cylinders MAINTENANCE BULLETIN 'Mill Type' roundline cylinders for working pressures up to 250 bar Complete service manual for the Parker MA3 Series Industrial Equipment. It provides technical information on device instructions, system checks, performance optimization, installation.
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAM Usage and setup manual for the Parker IQAN-LSL Video Game Controller. This reference manual outlines backup procedures, component overview, application scenarios, interface navigation.
DC Drives: Frequently Requested PDF Instructions
Sonesse 28 WF Zigbee Li-ion EN Instructions ES Manual de instrucciones FR Notice Instruction manual for the SOMFY Sonesse 28 WF Zigbee DC Drives. The guide focuses on operational safety, usage procedures, product specifications, installation guides.
ISO9001 3 Functional Safety Solenoid Driver KCD2-SLD-Ex1.**** PROCESS AUTOMATION MANUAL User instruction booklet for the Pepperl+Fuchs KCD2-SLD-Ex1 Series DC Drives. This guide offers guidance on user instructions, user settings, product specifications, security instructions.
DMX 227 Dosing pump Installation and operating instructions GRUNDFOS INSTRUCTIONS Further languages http://net.grundfos.com/qr/i/99559294 Instruction guidebook for the Grundfos DMX 227 Water Pump. The guide provides instructions on performance details, installation steps, hardware instructions, maintenance procedures.
KHB 13.0003-EN .4&ö Ä.4&öä Communication Manual Servo Drives 930 931M/W CANopen L-force Drives Practical operating guide for the Lenze 931M Series Inverter. The document presents component replacement, application scenarios, operating conditions.