Sharp R-CD1800M Operation Manual
Text of Sharp R-CD1800M Operation Manual
Sharp R-CD1800M DATE OF PURCHASE
Dealer
Telephone
Servicer
Telephone
TO PHONE:
SERVICE and PARTS
(for your nearest Sharp Authorized Servicer and Parts Distributor)
ADDITIONAL CUSTOMER INFORMATION
United States
1-877-427-7696
Canada
(905)568-7140
TO WRITE:
United States
Sharp Electronics Corporation
Customer Assistance Center
1300 Naperville Drive
Romeoville, IL 60446-1091
Canada
SHARP ELECTRONICS OF CANADA LTD.
335 Britannia Road East Mississ
(a) Do not attempt to operate this oven with the door open since open-door operation
can result in harmful exposure to microwave energy. It is important not to defeat
or tamper with the safety interlocks.
(b) Do not place any object between the oven front face and the door or allow soil or
cleaner residue to accumulate on sealing surfaces.
(c) Do not operate the oven if it is damaged. It is particularly important that the oven
door close properl
Contract your Sharp Authorized Servicer to ob-
tain on-site service for this Product. The Servicer
will come to your location and if it is necessary to
remove the Product, the Servicer will reinstall it.
Be sure to have Proof of Purchase available.
Where to Obtain Service:
Non-functional accessories and light bulb.
Additional Item(s) Excluded from
Warranty Coverage (if any):
Three (3) years for parts and labor in the end
user’s place of business.
Warra
When using electrical appliances basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of burns, electric shock, fire, injury to persons or exposure to
excessive microwave energy:
1. Read all instructions before using the appliance.
2. Read and follow the specific
“PRECAUTIONS TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE ENERGY” on page 1.
3. This appliance must be grounded. Connect only to properl
Please check the following before calling for service!
1. Plug the power cord into a three-pronged electric-outlet. (See page 5)
2. Place one cup of water in a glass measure in the oven and close the door securely.
A. Does the oven light come on?
Yes _________No ________
B. Does the cooling fan work?
Yes _________No ________
(Put your hand over the back ventilating opening.)
C. If “No”, please check wall outlet and circuit breaker.
3. Touch these pad
Should any of maintenance indicators appear in readout, follow the instruction:
Note
1. The “CC**” indicator will apear in the display when recommended parts life is
exceeded. The CC** indicator can be cleared by pressing the STOP/CLEAR pad. Call
for service to replace the parts promptly. Failure to replace parts that have exceeded
recommended operation time may cause failure of the microwave oven.
2. When more than one maintenance
Because your Sharp Commercial Microwave Oven will be used frequently, place it so that there
is easy safe access for all users.
1. Be sure all electrical requirements are met. See page 5.
2. Remove all packing materials from the oven cavity. Check the unit for any damage, such as a
misaligned door, damaged door seals around the door or dents inside the oven cavity or on
the door. If there is any damage, please do not operate the oven until it has been
1. Touch control panels
2. Door latch openings
3. Ceramic shelf
4. Splash cover
5. Oven light
6. Air intake filter
7. Air intake openings
8. Door seals and sealings surfaces
9. Door hinges
10. Oven door with see-through window
11. Door latches
12. Door handle
13. Service window for replacing the oven
light bulb
14. Ventilation openings
15. Power supply cord
16. Mounting plate
17. Screw for mounting plate
18. Oven Ceiling Cover
1. SELECT TIME
Before operating your new oven, make sure you read
and understand this operation manual completely.
1) Plug in the oven.
*The digital display will then show “ . “
2) You can input the pads only when the door is closed.
3) Oven light and fan motor work for 1 minute whenever
the door is opened or after cooking.
MEMORY OPERATION
Memory Cooking
* Before Memory cooking, make sure memory is set.
See the way of memory program entry
Sharp R-CD1800M 1 Place food in oven.
Press the DOUBLE/TRIPLE QUANTITY
pad twice.
2
x2/x3 x 2
Express Defrost with memory
*Suppose you want to cook with memory 0 ,
which was programmed for 10 minutes at Express
Defrost sequence, pre-programmed Direct Start.
Midway through the defrosting cycle, CHECK will
light in the display and an audible signal will be heard
depending on the setting. You may open the door,
turn food over and shield any warm portions. Close
1 Place food in oven and press the SELECT TIME pad.
Enter cooking time for 1st stage.
Procedure
1 0 0
SELECT
TIME
2 Press the SELECT POWER pad.
Enter power level for 1st stage.
3 Press the SELECT TIME pad.
Enter cooking time for 2nd stage.
4 Press the SELECT POWER pad.
Enter power level for 2nd stage.
6 Press the Touch START pad.
SELECT
POWER
SELECT
TIME
SELECT
POWER
5
7
5 Press the SELECT TIME pad.
Enter cooking time for 3rd stage.
2
TIPS:
Sharp R-CD1800M Program & Customize
Custom Help
You can check your oven setting and customize
your oven by changing CUSTOM HELP setting.
The CUSTOM HELP pad has 11 operations.
1. Selecting Memory Input method
2. Selecting Auto Start Operation
(for Direct Input and Repeat Input)
3. Program Lock Setting
4. Cooking Completion Sound Volume Setting
5. Cooking Completion Signal Setting
6. Memory Cook Data Check
7. Total used Counter Check/Clear
8
4. Volume Setting
There is a choice of 2 different sound volumes and
mute on your oven.
Custom Help41 : High = Factory Setting
Custom Help42 : Medium
Custom Help43 : mute
To set cooking completion sound volume
Press the CUSTOM HELP pad twice within 2 seconds
then enter the number 4, 1 for High
4, 2 for medium
4, 3 for no sound
and then press the START pad and the ST
Total memory Press each number pad
count
of memory.
Total manual
Press the SELECT TIME
cooking count pad.
Total Express
Press the EXPRESS
Defrost count
DEFROST pad.
* Suppose you want to know total used count
and total used count of each memory. In that
case the oven was used 8268 times and the
memory 1 pre-programmed Repeat Input was
used 513 times.
NO. CHECK
NO. CHECK
Procedure
Display
1 Press the CUSTOM
HELP pad twice
Sharp R-CD1800M NOTE : Press the STOP/CLEAR pad to exit from
the Custom Help function.
To Clear the total used air intake fi lter time
Clear the total used air intake fi lter time after
cleaning the air intake fi lter.
* Suppose you want to clear the total used air
intake fi lter time. In that case the air intake fi lter
was used 101 hours and the limit time for using
the air intake fi lter is preset to 100.
1 Press the CUSTOM HELP
pad twice
1. Press the STOP/CLEAR pad to exit from the
Custom Help function.
2. The multiplication factors can be set from
0.01 to 9.99 for double quantity and triple
quantity.
3. When you want to know the multiplication
factor for triple quantity, press the DOUBLE/
TRIPLE QUANTITY twice at step 1 after
pressing the CUSTOM HELP pad twice.
4. When you want to change the multiplication
factor for double or triple quantity continuously,
enter memory number
1. To exit from Express Defrost Setting mode,
press the STOP/CLEAR pad.
2. See page E-10 for the table for Microwave Power
Level. See the table for The Pause Timing
3. You can enter minus numbers for B1 and B2 at
step 3 and 6.
In that case,
press the SELECT TIME pad twice at step 3 and 6
(
is displayed.) and enter desired time for
B1 and B2 at Stage 1 and 2.
One more pressing the SELECT TIME pad before
entering the tim
Note: 1. If you do not press the SET MEMORY pad
within 2 sec. at step 1, the SET MEMORY
mode will be invalid.
2. If the cooking time is over the maximum
time, the display will show “EE9” therefore
to cancel it press the STOP/CLEAR pad.
* Suppose you want to set 1 minute at 70% in
the memory 12.
1
Procedure
Display
SET MEMORY X 2
Press the SET
MEMORY pad
twice within 2 sec.
2 Enter memory
number.
NO
2 2
3 Press the SELECT
TIME