- Monitor is 12.1 inches

- LINUX operating system – not windows - Can-based communication. No serial ports - New part number 3132-10

The following offers a general guide to the meaning of

battery status LED colors. Battery fully charged Battery partly charged Battery flat Charging (flashing) The following offers a general guide to the meaning of power supply status LED colors. Good supply Low supply Very low supply or off

Day/Night mode changes the brightness of the display.

Settings are Day, Night and Auto. Auto light mode will set the mode automatically depending on light conditions Brightness Control adjusts the brightness of the display. Use plus or minus to adjust display. Use the Topcon Logo for screen shots or navigate through your made global home screens. Before removing the USB, always disconnect first by touching the USB Eject icon on the base of the console. A message will display that it is safe to remove the USB.

- Added into the cab of tractor

- Replaces SRC interface box used for the X20 - Translates RS485 from on tank ECU to CAN for X30 - ISOBUS Capable ( can be used with a ISO terminal future) - Bourgault Part Number 3132-13 - Topcon number AGA4634 - Both the ISO bridge adapter cable and the main power cable hooks into this - Upgradeable though the USB port

- Connects X30 to power, bridge ECU, GPS

Signal, remote steer engage ( if equipped with Topcon) - Bourgault Part Number 3132-12-01 - Topcon Harness AGA5072 X30 Main Harness Hooks to main battery cable. CAN 1 to the ISO bridge through the Can harness ENGAGE wire Hooks to the ISO bridge adapter cable AGA4885 Switched power connects to terminator Harness AGA4678 COM 2 hooks to outside receiver for GPS COM 1 Hooks to GPS adapter cable AGA4219 for connection to outside receiver for GPS NOTE; GPS can be brought in though either COM 1 or Com 2 Also the can 2, remote mapping and radar plugs are not used. Power and communication plugs that hook to the back of the X30

- Connects bridge ECU to Topcon monitor harness

- Bourgault Part number 3132-09-01 - Harness Number AGA5251 Hooks to the ISO Bridge Connects to the can1 plug on the main power Harness AGA5072 Connects to the terminator harness AGA4678

- Connects Can harness to Topcon monitor harness

- Bourgault Part number 3132-09-02 - Harness Number AGA4678 Terminator part number Bourgault 3132-09-03 Topcon AGK159 Connects to the iosbus plug on the Can harness AGA5251 Connects to switched power plug on the monitor harness AGA5072

Bridge ECU adapter harness

- Connects bridge ECU to Topcon tractor harness - Connects Switchbox and Switch power to the ISO bridge. - Bourgault Part number 3132-06 - Harness Number AGA4885 Hooks to the ISO Bridge Hooks to the tractor harness Hooks to cabin switch box X30 engage wire Hooks to the engage wire on the main power Harness AGA5072

X30 power Harness

- Connects X30 main harness to the battery - Included in 3132-04 package - Highly recommended to hook direct to the battery - Bourgault Part Number 3132-04-03 - Topcon Harness AGA4073 Hooks to the main X30 power harness

GPS Adapter Harness

- Connects receivers to Main X30 harness on Com 1 - Includes gender changer/ Null Modem - Bourgault Part number 3132-04-04 - Topcon Harness AGA4219

Multi clutch switch box

- Master switch - Six tank switches - Bourgault Part number 3132-01 Hooks to the ISO bridge adapter harness AGA4885

4. Light bar (used for steering)

5. Environment 6. Map 7. Access

- Just touch each bar to

Set the Date format: the way it shows Set the Time format: 12hrs or 24hrs Set the current time: this will set itself when you hook to GPS signal

- Units: imperial (US)

- Latitude: DMS - Pressure: PSI - Area: acre - Dry Product: bushels - Dry Density: pounds per cubic foot - Liquid units: Gallons - Application Rate: fixed rate

-Audio Volume %

The volume of the audio and button clicks. - Button Clicks on/off Clicking sound every time you touch a button. -Alarm Audio on/off Whether or not you want the audio part of the alarm -Touchscreen Calibration If the screen is out of calibration. Restart required -Sensitivity of touchscreen Change the sensitivity. Restart required -Multi-function Region Mode this is talking about the Topcon symbol on the front of the monitor. When screen shots is selected it allows you to take a picture of the screen your on. When global home screen is selected it allows you to build home screens and you can toggle through with touching the Topcon symbol. -System transfer Not used -Steering status used for Topcon steering

- Point of focus: Allows you to set the point of

focus to either the vehicle or the implement - Map Planning: allows you to pan though the map with your finger and drag it to where ever you like. So you can see parts of the map that aren't on the screen - Map focus auto shift: if this is enabled it will automatically refit the map in the guidance screen when you have any mini views out. - Highlight loaded coverage: when enabled, as product is being applied covered area will be in green and the previously covered will be yellow. - Visual reference line length: allows you to Set a visual reference line length

- Allows for access to some feature

(like diagnostics) not accessible at the Operator level - Provision USB for upgrade This allows you to unlock the software on a thumb drive when an update is required.

- Guidance (this is always enabled)

- Auto Steer (used with Topcon Steer) - Reverse Detection (Topcon Steer) - Controlled Traffic (Topcon Steer) - Job Helper Mode adds a pop up menu to the guidance screen for navigation ease. You can have either Job Assist or Quick Start.

-Auto Sectional Control: ON if you want

the guidance to turn the clutches on and off. Or if your using sectional control NH3 or Liquid. -Variable Rate Control if using a VR map -Task Data (not used) -Agjunction (not used) Implements

GPS Receiver use other for non

Topcon - Baud Rate set to the rate that your receiver is outputting.

Receiver Com this needs to be set to

match the way that you have brought in the signal into the X30 Output Com have this set to something different then what the receiver Com is

-Area counters (on/off)

-Reset area (never, auto, and Prompt) Never: area will never reset unless the operator does it Auto: it will automatically reset every time they start a new job. Prompt: it will prompt you every time that you start a new job Area Counters

- You can change between different vehicles

that you have created - You can load a vehicle from another monitor through a USB - If you change the vehicle in this page it will restart the monitor

- This is were you can go in and create a new

vehicle by selecting the proper manufacture. - Then it will ask you to pick the model of the unit if its not there pick a model that is close to right one.

- After the unit is picked you will have to

come in and adjust the measurements specific to each vehicle - Ensure distance from receiver to rear axle, rear axle to the hitch and the receiver to the center of the machine are accurate as this will affect ASC/Mapping - The rest are primarily for steering application - Some steer systems require odd dimensions to steer (AES25) Topcon

- This is were you will pick the machine

that you are operating - Every time you create a new profile it will appear here

-Follow though a few steps to configure

your monitor to the machine you are working with. -Start by picking the series of tank that you have. Touch and highlight the proper one then press the green arrow. -Setting up a profile for both 6000/7000 a basically the same as you go though

Select the model for tank by highlighting

it then press the green arrow to move on.

This is were you pick how your machine

is configured. How many meters and weather or not you have sectional NH3/LIQ. Find the one that fits your tank and highlight it and press the green check mark. NOTE: you will see in a four tank configuration that it has a T3 or a T5. T3 - means that the fourth meter is on tank three. T5 – means that the fourth meter is on the saddle tank.

Pick Bourgault then go ahead and press

the green check mark. - At this point it will tell you that the X30 will need to preform a reboot. Just touch on the green check mark to move on.

Highlight the machine that you will

be using. Then press the green check mark to proceed. - If the machine that you are using is not listed you will have to pick one. After you have to go into the geometry and change the dimensions to fit the machine you have.

Find the machine that fits then

highlight it and hit the green check mark to move on

Pic the one that matches the your

machine, highlight and pick the green check mark to move on.

On this screen it allows you to the

name the unit simply by touching on the box with the name in it. - Then a key pad will come up for you to type the name. - When finished then touch the green check mark to move on - So when its on the select tab you will be able to recognized it.

- This page shows what ECU and drive each

tank is working through it will also let you know what firmware versions they are running when connected to the tank

These values should be set into the monitor

from the factory but should be checked to make sure. A- enter the width of the implement. If using Sectional control the value will be entered in the section setup screen B- overlap (not used) C- depth (not used) D- from the pin to the front row of openers or MRB E- from the main pin to the center of the caster hub or the High Flotation hub H- from the front row of openers to the back row of openers.

- Enter # of section and the width of each for the

Multi-section boom - It can be set all the same or individually - If using multi-section the total width will auto Populate into the geometry screen - Nozzles numbers only come into effect with Liquid

- Look ahead times for the individual section

valves - For NH3/ LQd would typically be the same as the tank on/off times - This will come more into affect with granular

- Enable a virtual switchbox so that you can manually

control sections on screen - This virtual switchbox will show up on the guidance Page - Only works if your using sectional control

- Related to section valve state monitoring, not

Applicable without granular section control

-Master Switch –

- virtual - allows you to use the touchscreen -cabin switchbox – to use the external switchbox -Implement – to use the machine to turn the clutch on -On position UP -Cabin switchbox - 6 channel if your going to use the external box it must be put on this setting - disabled if your not going to use the external box -Calibration enabled Switch Box

- Accessed by selecting the tab on the top of the

Individual tank’s - Name ( Bin/Tank) - Product as name (enable/disable) * Sequencing on time (0-10 sec) * Sequencing off time (0-10 sec) ** Preload time (0-15 sec) - Fan to start- ensures a min speed before the metering can be activated. Can prevent plugging/ meter damage. Should be set to around 1000 - Master clutch used with 6000 AS General Tank Setup

Name you can name how it is seen on

the seed rate controller screen. - Capacity the amount of product that will fit in the tank. It can be altered. - Status if not using one of the tanks you can come in and disable them. - Accessed by selecting one of the numbered tabs on the left hand side. Or the arrow to move the tanks up or down HINT: if tank is not being used disable it otherwise system won’t allow you to start applying. All enabled tanks need a cal factor even if they are switched off

Groupings are pre-set from the factory use the

arrows on the right hand side to scroll though them - Tank volumes update automatically

- Toggle between the tanks with the tabs on the

left Hand side - Drive type – proportional for 7000 AS - linear for 6000 AS - Pulses/ Revolution – 32 for 7000 AS 16 for 6000 AS - Minimum RPM set at 10 - Maximum RPM set at 1000 - Metering Auger pick corresponding augers to each tank - Accessed by selecting one of the numbered tabs on the left hand side. Or the arrow to move the tanks up or down

-Minimum PWM (15%)

-Maximum PWM (95%) -Controller Response (medium fast) - Accessed by selecting one of the numbered tabs on the left hand side. Or the arrow to move the tanks up or down

- Product Name enabled/disabled

- Sequence On/Off Times work similar basis as granular on/off, based on time for product to reach openers after switched on/off, usually a bit faster then granular

- Name - can name each tank/bin

- Capacity – can be changed to match your tank - Status (enable/disable) if your not using one for a field - Section Control (NH3 if you are, full width if single boom - Pump Speed (not used)

- Calibration Factor – Can be set here or on the

SRC screen - Flow Confirmation (not used)

- Toggle though the different fans using the tabs

On the left hand side - Fan speed – disable if not using one of fans - Pulses (1)

Blocked Head Monitor

- Block head monitor (enabled/disabled) - Sensor Type (dickey - john) - Head monitoring Single/double shoot - Number of sensors 1 – 20 max - On the right hand you can name individual runs

Speed source GPS

- Fallback Type manual speed - Wheel Factor this is used when you switch the speed source to wheel. It will be set from the factory. NOTE: GPS speed should be used at all times. Wheel speed is not consistent enough because of the amount of tire deflection. The rolling radius of the tires on the bigger machines can changed up to 20% from full to empty

You will need to come in and enter the

products that will be used with this air seeder - You are able to add new products at anytime. - The way of entering new products is the same weather its liquid, granular or NH3. - Touch on the New Product tab to start to enter a new product

Scroll though the list to find the

product that you are wanting then highlight it and press the yellow arrow. - If the product is not in this list find one that would be close in density. We can rename the product and change the density in the coming slides.

- Now you can rename the product to what

ever you like. Just touch on the product name then it will bring up a keyboard so it can be named. When finished touch on the yellow arrow to move on.

Density - Now you can go in and enter an

known density if needed. Rate Increments – the amount that the rate will change every time you touch the up or down arrow on the SRC screen. Rate preset 1 – set the rate that you want to be using this product at. Rate preset 2 – set a secondary rate you might want to use. Once this is set every time you bring this product into one of your tanks these figures will auto populate in to the screen