Prolon PL-RS Quick Start Manual

Specifications

Brand: Prolon
Category: Controller
Model: PL-RS (Quick Start Manual), przU6QmC2xMS.
File Type: PDF
File Size: —
Pages: 18 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (18 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 15/08/2026).

Read Online

Read the Prolon PL-RS Quick Start Manual online using the built-in PDF viewer.

PL-RS Quick Start Manual: Key Pages of Document

QUICK START GUIDE

VAV CONTROLLERS & WALL SENSORS www.proloncontrols.com | [email protected] 17 510 rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV 1.0 PL-QCK-WSENSOR/VC2000-EN ...

© Copyright 2018 Prolon. All rights reserved.

No part of this document may be photocopied or reproduced by any means, or translated to another language without prior written consent of Prolon. All specifications are nominal and may change as design improvements are introduced. Prolon shall not be liable for damages resulting from misapplication or misuse of its products. All trademarks are the property of their respective owners. ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

3 Analog Sensor (PL-RS)..................................................................................................4 Dimensions and Wiring......................................................................................4 Digital Sensor (PL-T200)................................................................................................6 Dimensions and Wiring......................................................................................6 Digital Sensor (PL-T500)................................................................................................8. Dimensions and Wiring............... ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

4 Analog Sensor (PL-RS) 4.96” (126 mm) 1.30” (33 mm) Schedule override Dimensions and Wiring ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

5 COM THERM COM POT 3.23” (82 mm) Room temperature Setpoint (10K) Temperature table (thermistor: 10K Type 3) Fahrenheit 41 50 59 68 77 86 95 104 Celsius 5 10 15 20 25 30 35 40 Ohms 25395 19903 15714 12493 10000 8056 6530 5324 ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

6 Digital Sensor (PL-T200) Dimensions and Wiring 4.96” (126 mm) 1.30” (33 mm) Schedule override (hold for 3 second) ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

7 INT A (+) INT B (-) 24VAC COM 3.23” (82 mm) Communication (RS485) Power (2 VA max) RJ45 connection (to C1000) ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

8 Digital Sensor (PL-T500) Dimensions and Wiring 4.96” (126 mm) 1.30” (33 mm) Schedule override: Hold 3 seconds Change unit °F/°C: Double-click ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

9 INT A (+) INT B (-) 24VAC COM 3.23” (82 mm) Communication (RS485) Power (2 VA max) RJ45 connection (to C1000) ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

10 Digital Sensor (PL-T1000) Installation 1. Open casing to remove back cover by pushing on the tab located underneath the thermostat. (See Figure 1) 2. Pull wire(s) throught central hole of back cover. 3. Screw in the back cover to the wall. 4. Connect wires: • If using twisted pair wires: - Pull out screw terminal block. - Remove 1 cm insulation from each wire. - Connect the wires to the terminal blocks and reconnect the terminal blocks. (See Figure 2) • If using CAT5 cable: - Plug the cable into the RJ45 jack of the T1000 (if CAT5 cable is opened at the controller, refer to Figure 3 for pinout of ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

11 Figure 1 Figure 2 Figure 3 INT A INT B 24 VAC COM 24V RJ45 (Female) ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

12 Digital Sensor (PL-T1000) Auxiliary Analog Input The T1000 has auxiliary analog input which can be used to connect another thermistor. The T1000 can be configured to use this alternate temperature reading for a variety of functions, including temperature averaging or radiant floor slab temperature. The alternate thermistor (10KΩ type 3) can be connected to the auxiliary input using the “AUX IN“ and “COM“ pins. (See figure below) Analog Input Operation The T1000 is controlled using the circular touch pad on the bottom half of the thermostat. The touch pad uses capacitive sensing technology to detect fing ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

13 Changing the Setpoint Schedule Override The First, go to the Setpoint screen. Scroll or tap (any direction) Heat SP Cool SP Adjust your setpoint by scrolling clockwise or counterckwise View current zone temperature Home Screen Setpoint Screen Tap anywhere (or simply wait) return to Home Screen The sun icon is displayed when overridden OVERRIDE ACTIVE (Occupied mode) The moon icon indicates unoccupied mode Scroll clockwise to override 67.5 79.5 67.5 79.5 ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

14 VAV Zone Controller (PL-C1000-VAV) 32-122 °F (0-50 °C) Non-condensing ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

15 INT Port: Incoming Modbus RS485 communication from digital sensor -OR- Remote computer with Prolon Focus software Digital Input for night setback / Standby mode Multi-function analog input Common for all the inputs Temperature setpoint (0-10K potentiometer) Room temperature sensor (10K thermistor) Output 5 (analog 0-10VDC) (Max Current: 40 mA) Output 4 - Isolated or source, TRIAC 24 VAC (max current: 300 mA) Output 3 - Isolated or source, TRIAC 24 VAC (max current: 300 mA) Output 2 - Isolated or source, TRIAC 24 VAC (max current: 300 mA) Output 1 - Isolated or source, TRIAC 24 VAC (max current: 300 mA) Power sou ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

16 VAV Zone Controller (PL-VC2000) 32-122 °F (0-50 °C) Non-condensing ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

17 Service pin General purpose analog input (0-5 VDC, 4-20mA, 10K thermistor) Supply / Radiant / Zone / Occupancy / Discharge Digital sensor (T1000, T500 or T200) / Remote computer with Focus Analog output (0-10 VDC) (max current: 40 mA) Network communication Digital output - Isolated Triac Dry contact (24 VAC) (max current: 750 mA) Power source of the controller (24 VAC - Class 2) Airflow Sensor (PL-VC2000-PI) Airflow sensors are only included in the PL-VC2000-PI models only. Adding an airflow sensor to the Prolon VC2000 lets it regulate the airflow as well as temperature in a zone, independently of the static pre ...

REV 1.0 / PL-QCK-WSENSOR/VC2000-EN

18 Compliance Technical Specifications Digital Sensor (PL-T1000) • FCC Compliant to CFR47, Part 15, Subpart B, Class B • Industry Canada (IC) Compliant to ICES-003, Issue 5: CAN ICES-3 (B) / NMB-3(B) • RoHS Directive (2002/95/EC) VAV Zone Controller (PL-C1000-VAV / PL-VC2000) • cULus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 • CAN/CSA-C22.2 No. 2015-12, Signal Equipment • FCC Compliant to CFR47, Part 15, Subpart B, Class B • Industry Canada (IC) Compliant to ICES-003, Issue 5: CAN ICES-3 (B)/NMB-3(B) • RoHS Directive (2002/95/EC) FCC User Information This device complies with P ...

Controller PDF Instructions

MPPT20CC
Renogy MPPT20CC
12.06.2026 29 pages

MPPT20CC RENOGY 20A Maximum Power Point Tracking Solar Charge Controller Manual 14288 Central Ave., Suite A Chino, CA 91710 1-800-330-8678 Manual for installation and usage of the Renogy MPPT20CC Controller. It offers details on setup guidelines, user settings, specifications.

DeltaTherm E
Resol DeltaTherm E
29.05.2026 32 pages

* 11213873* 11213873 DeltaTherm® E Manual en Control unit Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting Thank you for buying this RESOL product. Please read this manual carefully to get the best performan Technical setup manual for the Resol DeltaTherm E Control Unit. This reference manual outlines hardware setup, maintenance guidelines, device features, software installation.

pipeo
Vitlab pipeo
12.03.2026 44 pages

VITLAB GmbH Linus-Pauling-Str.1 63762 Grossostheim Germany tel: +49 6026 97799-0 fax: +49 6026 97799-30 [email protected] www.vitlab.com Accessoires de pipetage / Pipet Controller pipeo® Mode d’emploi Operating Manual Operating instructions for the Vitlab pipeo Controller. It explains installation, setup, and operating guidelines, device calibration, operational safety.

C8051F38X
Silicon Laboratories C8051F38X
30.04.2026 12 pages

Rev. 0.2 2/14 Copyright © 2014 by Silicon Laboratories C8051F38x C8051F38x C8051F38X DEVELOPMENT KIT USER’S GUIDE 1. Kit Contents The C8051F38x Development Kit contains the following items: C8051F380 Target Board C8051Fxxx Development Kit Quick Operation and maintenance manual for the Silicon Laboratories C8051F38X Controller. The manual provides information on control functions, regulatory notices, installation guides.