Electronic Balance HYPROP BALANCE Operation Manual To ensure safe and proper use of the balance, please read this manual carefully. After reading this manual, store it in a safe place near the balance, so you can review it as needed. IMPORTANT ...
instrument equipped with exacting mechanisms in a compact body. The HYPROP BALANCE Series provides enhanced functions, including a counting mode for stock control of parts, a percentage mode for comparative measurements given in percentages, and a limit function for measuring constant quantities by consecutive weighings. Despite its many functions, the balanc ...
2. Names of Component Parts 2.1 Main Unit ......................................... 5 2.2 LCD Indicators and Operating Keys .. ........................................................ 6 3. Basic Operations 3.1 Installation ....................................... 8 3.2 Operation Check ............................. 9 3.3 Operation for Tare Subtraction ...... 10 4. Functions 4.1 Setup ...
This Section "Precautions Relating to Use" sets forth precautionary notes that the user should observe in order to prevent physical injury to the user and/or damage to property. The nature of problems that may result in the event of improper operation, and consequential effects on the quality and performance of the balance, are indicated under the two categories of "Caution" and "Recommended," and explained using symbol ...
Do not place the balance on an unstable base or use the balance in a location where it may be subjected to shock. The loaded sample may fall off the measurement pan. Accurate measurement may be rendered impossible. 定格外禁止 Do Not Drop Do not lay the AC adapter cable on the surface of the passage. Somebody may trip on the cable, causing the balance to fall off, thereby causing injury and/or damage to ...
Force Avoid applying excess force or impact to the balance. Place the sample to be measured on the balance carefully to prevent breakage or malfunction. 定格外禁止 Do Not Use Do not use the balance in a location were it may be subjected to abrupt changes in ambient temperature or humidity. Accurate measurement may not be obtained. Optimum operations occur when ambient temperatures range from 10C to ...
2.1 Main Unit Operation keys See page 7. Level For checking the level of the balance Turn the adjusters until the bubble rests in the center of the red circle. Adjusters: Total of four, one on either side at front and rear AC adapter connector Measurement pan Liquid-crystal display (LCD) See page 6. USB connector Front View Rear view Calibration knob Used for span adjustment of the balance. ...
2.2.1 Symbols Displayed Display Description g Grams 0 Zero point NET Tare being subtracted ○ Indication of stable balance (If the light is off, the balance is unstable.) Balance powered up (Lights up when the power is turned off) or data transmitted Pcs Counting mode % Percentage mode Indication of judgement result (HI/OK/LO) when the limit function is active. mom Momme M Display of set values from memory ( ...
Operating Key Function On/off key Key to turn on/off the unit power Memory key [Brief press] initiates print or output. [Brief press] saves the settings of the number of pieces or percentages (%), or the limit value when using the limit function. Set key [Brief press] starts setting the number of pieces or percentages (%). [Continuous press] starts setting the limit value when using the limit function. Functio ...
3.1 Installation
1
Positioning the measurement pan
First, mount the pan base on the
main unit of the balance and place
the measurement pan on top of it.
2
Securing the exact level of the balance
Turn the adjusters until the bubble
rests in the center of the red circle
on the level.
* When the balance has the AC adapter connected, it displays [ ]. Pressing the On/Off key The display section lights up, and the balance is ready for operation. 2 Checking the display Check to see if the display has any missing indications or unlit parts. A few seconds after startup, the indication is reset to zero. (When lock switch is set on) After every segment lights, If something is loaded, the displ ...
1 Place the tare (container) on the balance. As you place the tare, the balance indicates its weight. 2 Reset read-out indication to zero. Press the Zero/Tare key. The tare is subtracted and the balance indicates zero. 3 Load the sample to be weighed. The balance will now indicate only the weight of the sample loaded in the tare. ☆ Weighing only the weight of an added sample 4 Resetting the indication to zero Pres ...
The following applies equally to all the measurement modes for weight measurement, counting, and percentages. 1. After the balance is switched off, there is still enough current to display [ ]. This indicates that the AC adapter is connected to an electrical outlet, but that the balance is turned off. When the balance is switched on again, [ ] will disappear. ※If the balance is running on batteries and the unit is ...
1 Invoking the function Press and hold down the Function key until the indicator changes to “Func,” then release the key. The function setup mode is activated, and the first item, [1. b.G. 1 (Bar graph) ] appears. (See “4.2 Description of Functions” on page 13.) 2 Selecting the next item Press the Function key. The indication changes to the next item, [2.SEL 0 (Limit function)]. 3 Select ...
Item Set Value Description Bar graph display 1. b.G. 0 Disable ☆1 Enable Limit function 2.SEL ☆0 Disable 1 Enable Displayed only when limit function is activated Judgement condition 21.Co. ☆1 Always judge (judges even when the balance is unstable) 2 Judge only when the balance is stable (does not judge if the balance is unstable) Judgement range 22.Li. 0 Ranges beyond +5 graduation is judged (ranges +5 graduation or ...
measurement to be displayed※1 81.S.u. | 85.S.u. ☆3 20 [Pcs] ☆4 IF [%] ☆5 00 Unit not set Display of the auxiliary scale interval 9. Ai 0 Disable ☆1 Enable ( is the auxiliary scale interval.) Note: The auxiliary-scale-interval place does not represent a verification scale interval. Use it only as a reference value. GLP-compliant print※2 0.GLP ☆0 Disable Prints a GLP-compliant format at calibration. (Refer to “9.3 GLP- ...
Pressing the Function key allows the user to switch the unit of measurement to [g], [ct], [%], and so on. Up to five different units can be registered for use only when the function key is properly set on a balance for which the lock switch is off. 5.1 Switching Units of Measurement Switching the units of measurement to be displayed g Pcs % Press the Function key. Each press advances through the units ...
Pressing the Set key will reset the measurement mode 4 Pressing the [Function] key to change the units of measurement g Pcs % Press the Function key. Each press of the key changes the units of measurement to be displayed, as follows: [g] [lb] [Pcs] [%] [g] · · · ☆ Key Points of the Procedure ☆ 1. When set values are entered in the function items [81.S.u.] to [85.S.u.] p ...
To implement piece-counting, the specified samples are loaded on the balance, and their average unit weight (hereinafter, simply the “unit weight”) is entered and saved. The procedure for saving unit weights is called sampling. The counting procedure consists of loading articles that have already been sampled on to the balance. The number of pieces is then calculated by dividing the total weight of the loaded articles by the uni ...