For improvement of product performance, supplementation, or follow-up of information, the contents of this

manual are subject to change without prior notice. Please note that our company will have no responsibility for accidental damage nor be obligated to perform warranty service for any damage to equipment due to user error, which is a result to

The device must be installed and used in accordance with the safety regulations and instructions supplied

in this user manual for the purposes and applications which it is intended for. Before each usage, check the outer surface of the EzSensor for any signs of physical damage or defect. The surface of the EzSensor should have a smooth fini

Authorized representative in the European Community.

Type B applied Indicates to the user to check the accompanying documents (this User Guide) for more information about EzSensor. Handle with care The E-WOO TECHNOLOGY logo and the following label can be found on the EzSensor device.

1. INTRODUCTION ......................................................................................................5

1.1. System Description ....................................................................................................... ............................... ..................................................5 1.2. Syste

1.1. System Description

EzSensor is a modern digital imaging solution for intraoral dental radiography. Its advanced CMOS technology provides excellent image quality. For patient comfort, the EzSensor’s ergonomic design is based on human intraoral anatomy. EzSensor is a digital X-ray imaging system designed specifically for

< Table 1. Specifications >

Parameter Detector Structure Dimension(W x L x T) Pixel Pitch Active Pixel Array Dynamic Range Signal to Noise Ratio USB Cable length between Controller and PC 6 Description Low Noise Hybrid CMOS 1.14 x 1.52 x 0.19 inch (29.2 x 38.7 x 4.9 mm) 0.035 mm 686 x 944 pixels (24.01 x 33.04 mm) 4096 >37dB 3 m

1.2. System Components

The EzSensor device installer should check the following items listed in the table below before system installation. If the serial numbers of the individual parts do not match, do not install the system and contact your local distributor or agent for support. < Table 2. EzSensor Cable Connections > No 1. 2. Sensor Modul

2. Control Box

Provides power for the sensor, timing and synchronization of sensor signals, signal pre-amplification, analogue/digital signal conversion, USB port interface and optical insulation of all connections. 3. USB Cable(3M) Used to transmit output signal from the control box to the computer. 4. Control Box Mount Used to mount the con