Teknim VAP404 Installation & Operation Manuals
Read Online
Read the Teknim VAP404 Installation & Operation Manuals online using the built-in PDF viewer.
Key Pages of Document
Issue Date: 09/07/2013 Software version 3.0 and higher TD-1/07-008 ...
SAFETY PRECAUTIONS Read this guide carefully before operating device and keep this guide for later reference. Follow all operating and safety instructions in this guide. Keep devices away from dust and moisture. Locate device to the straight place in order not to damage it. Use device together with metal box . OPERATING CONDITIONS : Don� ...
TABLE OF CONTENTS 1. INTRODUCTION 5 2. FEATURES 6 3. MOUNTING 3.1. GENERAL 7 3.2. SIREN CONNECTION 8 3.3. DETECTOR CONNECTION 8 3.4. KEYPAD CONNECTION 12 3.5. TELEPHONE LINE CONNECTION 12 3.6. CONNECTING OF PROGRAMMABLE OUTPUTS 13 3.7. CONNECTION OF PANEL ARMED OUTPUT (ARM) 13 3.8. POWER CONNECTION 14 4. QUICK & SIMPLE PROGRAMMI ...
8.5. USER SETTINGS 8.5.1. Start Time 57 8.5.2. Finish Time 58 8.5.3. User Days 59 8.5.4. User Partitions 59 8.5.5. User Keypads 60 8.5.6. User Limitations 61 8.6. CENTRAL MONITORING STATION & USER PHONE DIALER SETTINGS 8.6.1. General Features 61 8.6.2. Event Logs 65 8.6.3. Contact ID Event Codes 68 8.6.4. DTMF 4+2, etc Event Codes 70 8 ...
1. INTRODUCTION VAP404 is 4+4 zone alarm panel that meets desires. It has simple usage also let technician to configure user needs simply. Simple Mounting o Panel is mounted wall by three holes. o Panel case has cable holes to pass cables through Panel PCB. o Functions of terminals is written on PCB. Connect cables to proper place. o Conne ...
2. FEATURES Inputs o Programmable 4+4 zone o NC,NO, 1-EOL Resistor, 2-EOL Resistor zones, Double Zone. o Different zone types (Door, Window, Tamper, Fire etc.) o Additional features assigned zones(Follower zone, end zone, silent zone etc) o Enter/Exit delays for each partition. o KEY input to arm o Sabotage switch on Panel and Keypad Outpu ...
3. MOUNTING WARNING! : Don’t connect power to panel without finishing wiring. 3.1. GENERAL Drill necessary holes on the wall and then mount panel case to wall by using proper holes. Metal cover of panel constitute of body and cover. Cover is opened by removing two screws. Detectors, siren, and telephone line are connected to Panel by us ...
3.2. SIREN CONNECTION Siren connection is made by 12V,SRN,GND terminals.12V and GND is supply voltage of Siren. Trigger output of Siren is SRN. Siren output can be programmed as NO ,NC. If 2 sirens is connected, one of sirens should be used in SCB mode. When 2 sirens are connected to panel, one of the sirens should be on SCB mode to incre ...
can be noticed. It is recommended to use double end of line resistor. 2.7kΩ resistor that comes with panel can be used for end of line connection. These resistors should be connected to detector sides. If more than one detector contacts is wanted to be serially connect, end of line resistor connection can’t be made, none- resistor conn ...
Zone number can be increased to 8 by zone doubling feature. You make zone doubling by using 1kΩ and 2kΩ resistors connected to zone as following picture. Zone doubling is enabled in Zone Wiring section of Installer Program. Each physical zone can be used as 2 zone by zone doubling. Contact types(NC,NO) of zones can be configured from ...