1 General: The 5 wires encoder unit is an intercom system, serves as door panel and encoder. With this unit you can speak with the visitor who is waiting at the door and open the electric lock from the intercom handset or from the phone using Tador 5 wires adapter. Authorized personnel can open the door by press ...

Tador Technologies CD-500 Installation guide

2 Handset wiring Several common handsets could be assembled. Electric buzzer handset can not be assembled. Wiring of different handsets is detailed in the electrical drawing in page 4 and the following table: Encoder terminal Amplyvox handset Videx handset Videx handset SMART 1P URMET wire Left pin 12VA-C ...

Tador Technologies CD-500 Installation guide

3 Changing the programming code Enter the programming code: if not changed is: 123456 confirm with *, the green led will blink. now the following sequence should be entered: memory cell number 99 , new programming code ,and for verification again the memory cell number 99, the same new programming code. Confirm ...

Tador Technologies CD-500 Installation guide

4 Microphone and speaker volume adjustments The Intercom Encoder unit leaves the manufacturer site adjusted. Sometimes because of the location (opened or closed space), acoustical problems occur. If the Encoder’s speaker sound level is too high or low, gently rotate the internal SP potentiometer.(clockwise to ...

Tador Technologies CD-500 Installation guide

5 Intercom Encoder Electrical drawing Lock Speaker volume adjustment Microphone volume adjustment 12VAC C DOOR COM SW MIC SPK PHONE LINE POWER LED1 LED2 JP2 JP3 5-Wires Adaptor RX SW MC SP 12VAC ממסר INTERCOM-CODE RLY DEFAULT MIC SP MIC SP J5 ממסר Line In Open - C and Door open contact Close (Default) - ...