RPB Z-LINK Instruction Manual

File Specifications

Brand: RPB
Category: Respiratory Product
Model: Z-LINK (Instruction Manual), prBxpkdlpAaTI
File Type: PDF
File Size: —
Pages: 48 pages

Download PDF

Download RPB Z-LINK Manual (48 pages)

Read Online:

Read the RPB Z-LINK Instruction Manual online using the built-in PDF viewer.

Key Pages of Document

Employers: Read this manual and the flow control device Instruction

Manual and carry out the Employer Responsibilities (page 9). Product users: Read this manual and the flow control device Instruction Manual and follow the Product User Safety Instructions (page 10). Make sure this manual is available to all users for reference. Español: w ...

 EXPLANATION OF SIGNAL WORDS AND SYMBOLS

2  INTRODUCTION 3  IMPORTANT SAFETY INFORMATION  PROTECTION PROVIDED AND LIMITATIONS 4  RESPIRATORY COMPONENT DIAGRAMS - NIOSH CAUTIONS & LIMITATIONS 6  AIR SOURCE, FITTINGS, AND PRESSURE 8  EMPLOYER RESPONSIBILITIES 9  PRODUCT USER SAFETY INSTRUCTIONS 10  BREATHING AIR PRESSURE TABLE 14 � ...

RPB® SAFETY - GLOBAL HEADQUARTERS

2807 Samoset Rd, Royal Oak, MI 48073, USA. T: 1-866-494-4599 F: 1-866-494-4509 E: [email protected] rpbsafety.com RPB® SAFETY - APAC 1 Ivan Jamieson Place, Christchurch Airport, Christchurch 8053 New Zealand. T: +64-3-357-1761 F: +64-3-357-1763 E: [email protected] rpbsafety.com RPB® SAFETY - EMEA Unit 2, ...

The RPB® Z-LINK® is approved by NIOSH as a Type C respirator in the categories as follows:

Powered Air The RPB® Z-LINK® Respirator, when properly fitted and used with all required components, including the Breathing Tube Assembly and the 03-901 RPB® PX4 AIR® Powered Air Purifying Respirator, is a NIOSH approved powered air purifying respi ...

 In abrasive blasting applications.

 For protection against hazardous gases (e.g., carbon monoxide).  Contaminants are in excess of regulations or recommendations.  Contaminants or contaminant concentrations are unknown.  Work area is poorly ventilated.  The temperature is outside the range of 14°F to 140°F (-10°C to +60°C).  A fla ...

RESPIRATOR COMPONENT DIAGRAM - PAPR

FIGURE 1.1 1. RESPIRATOR HELMET ASSEMBLY 2. BREATHING TUBE ASSEMBLY 3. AIR SUPPLY PX4 AIR® NIOSH - CAUTIONS AND LIMITATIONS POWERED AIR A. Not for use in atmospheres containing less than 19.5 percent oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentra ...

NIOSH - CAUTIONS AND

LIMITATIONS SUPPLIED AIR A. Not for use in atmospheres containing less than 19.5 percent oxygen. B. Not for use in atmospheres immediately dangerous to life or health. C. Do not exceed maximum use concentrations established by regulatory standards. D. Air-line respirators can be used only when the respirators are supplied with respirab ...

AIR SOURCE, FITTINGS, AND PRESSURE

AIR SOURCE Powered Air Check that the contaminated area is within the limits of use for a Powered Air Purifying Respirator and determine the type of contamination. Once the contamination level has been confirmed you can then determine the filter cartridge to be used for the application, to make sure that you are sufficien ...

Your specific responsibilities may vary by location and industry, but in general RPB® expects that

employers will:  Follow all applicable standards and regulations for your location, industry, and activity. Depending on your location and industry, a number of standards and regulations may apply to your selection and use of res ...

c) have an understanding of the site’s respirator program; and

d) be knowledgable of applicable regulations. Train each Z-LINK® user in the product’s use, application, inspection, maintenance, storage, fitting, and limitations in accordance with the content of this Instruction Manual and the approved flow control device Instruction Manual and stand ...