Gsertel Hexylon Operation & User’s Manual
Read Online
Read the Gsertel Hexylon Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
User manual w w w . g s e r t e l . c o m HIGH PERFORMANCE PORTABLE METER INTENDED FOR PROFESSIONAL USERS ADVANCED FEATURES AND HIGH MEASUREMENT ACCURACY all-guides com ...
4 Overview 5 Introducing the Hexylon 5 Key features 5 General Specifications 6 Technical Specifications 7 Description of equipment components 8 Connectors and controls 8 Keyboard 9 Power supply 9 About the battery 10 Separately battery charge 11 Gestures 11 Before starting 12 Icons in the screen 14 Bottom bar: 14 Top bar: 15 Menus 16 Top Menu 16 Main Menu 16 Options context menu 16 To ...
4 Servicing - There are no user serviceable parts except the battery pack. Do not attempt to service this product or remove covers. Remita todas las reparaciones a personal técnico cualificado. Refer all servicing to qualified service personnel. Follow the instructions in this manual when replacing the battery. Heat - The product should be situated away from heat sources such as radiators, heat registers, st ...
Hexylon is the new high-performance portable meter, with advanced features and high measurement accuracy. And all in the most automatic and intuitive way in the market, thanks to its intuitive interface and gestural commands. With Hexylon, technicians have a tool to measure, analyse and diagnose radio y TV signals in any scenario, no matter how complex. Hexylon has an ultra-fast spectrum analyser with high accuracy, t ...
6 General Specifications Display 8” Touch Screen TFT 1024x768 Full Color Weight 2150g Dimensions 250x210x60 mm (H x W x D) Power supply Input: 100-240V~ 50-60Hz Output: 12VDC, 4A Battery Li-ion (7,2VDC, 9000mAh). Field replaceable Operating time > 4 hours Operating temperature -5ºC a 45ºC (23ºF a 104ºF) Storage temperature -20ºC a 70ºC (-4ºF a 158ºF ) Humidity 5% a 95% no-condensation Interfaces ETH, US ...
Accuracy 1 kHz Tuning Freuqncy or channel Input Impedance Spectrum Analyser Span 100 KHz, 1, 5, 10, 20, 50, 100, 200, 500 MHz, 1.0, 2.0 and 3.3 GHz. Other (any value between 100 KHz and 3.3 GHz) RBW 500 Hz, 1, 3, 5, 10, 30, 50, 100, 300, 500 KHz, 1, 3, 5 MHz Marks Up to 4, with delta feature Event trigger Waterfall Hold feature Maximum and minimum Reference level Automatic and manual Digital measur ...
8 Description of equipment components Connectors and controls 1. Touch screen 8” 2. Connectors 3. Keyboard and LED indicators 4. Battery (on the back) 1. F.O. 6. CAM 9. USB 2. Power connector 7. USB 10. A/V 3. ASI 8. RF Input 11. GPS 4. ETHERNET 5. HDMI TILT Attenuation Multi TS FM Measurements Level C/N Up to 52dB RDS DAB/DAB+ Measurements (option 901629) Power De 20 - 128 dBµV MER Up to 20 ...
off, press and hold for approximately 3 seconds 2. Menu button: First press-features menu is shown. Second press-top menu is shown. Third press-context menu is shown. Fourth press-all menus are hidden 3. Up/Down buttons: Changes channel 4. Left/Right buttons: Changes screen in multi- screen features 6. Powering LED: Indicates if the equipment is powering an external load Power su ...
10 About the battery Important: If the equipment is going to be stored for a while, it is recommended to take the battery off and store them both separately. To maximize battery life: Allow fully discharging the battery. The battery can be charged correctly attached to the device and using the supplied DC adapter. Or separately using the the DC adapater supplied with the Hexylon. For long term storage, take the ...
designed to get the most out of its 8” multi-touch display. To do this, Hexylon uses some gestural commands that are explained below: Tap: one fast touch with one finger Double tap: two fast consecutive touches with one finger Swipe: short swipe with one finger Drag: drag with one finger Pinch/Spread: pinch/spread two fingers on the screen Drag and drop Separately battery charge The battery ...
12 Before starting The first time you turn your Hexylon on, please follow the next steps for a proper registration. To do that, you must be registered on our website (www.gsertel.com) In addition, you need internet connection (Ethernet or Wi-Fi). Then, please follow the next steps that will be shown in the screen: 1.- Choose the language 2.- Select the internet connection (Ethernet or Wi- Fi): Tap to continue Scroll ...
networks will appear on the screen. You must select one of them to access the internet. 4.- When your Hexylon is connected to the internet, you have to enter you Gsertel account data (e-mail and password) 5.- Your Hexylon is registered!: Skip: cancel the registration. If you skip, you will be prompted to register your meter each time you turn it on Back: back to previous step Next: goes to the next ...
14 • Change band: see section 2.- User profiles • Change profile: changes the user profile. See section 2.- User profiles • MacroLOG: allows you to schedule repetitive measures in time intervals selected by the user. See section 9.- LOGs • TS or RF recording: TS recording is always available (option 901628), except when the user selects the spectrum feature (see section 7.- Spectrum Analyzer). In this case, t ...
meter is connected to the network by Ethernet. See section Settings-Network in Top Muenu • Wi-Fi: indicates that the meter is connected to a Wi-Fi network. See section Settings-Wi-Fi in Top Menu • GPS: indicates that the GPS is active. While the satellite data is not received, the icon blinks. See section Settings-GPS in Top menu. To perform a Drive-Test the GPS must be active, and then s ...
16 Menus The Hexylon has 3 different menus. These menus will be explained in this section briefly, as well as their locations. All their features will be explained in the sections below. Top Menu To access this menu you must do a short swipe in the top central part of the screen. The features of this menu allows us to set up certains aspects of the meter in a fast way and from any feature. Main Menu To access this me ...
take a few seconds to be locked): Then close the Top Menu window, and you will the a window like this: NOTE: The TS Recording should last at least 20 seconds for the TS Player feature can play it. Once you tap on the TS Player button, it will be displayed the list of the TS Recordings: Tap on TS Player to select the file Select the file you want to play and tap on Start Then turn it ON Tap on TS Player ...
18 Powering: Allows setup the preamplifiers powering. Settings: The user can set the following parameter from this menu: • Brightness: increase/decrease the display brightness • • • • Tap to select Consumption information Increase/decrease doing “drag” Tap to select the parameter • Volume: increases/decreases the volume • Touch: increases/decreases the sensitivity of the touch control Increases/Decr ...
• GPS: Enables/disables the GPS feature. When it is enabled, the corresponding icon appears on the top bar of the screen. While the Hexylon does not receive the satellite signal, the GPS icon will blink. • Network: Allows to set up the equipment network connection. If the user selects the DHCP mode (DHCP ON), the network parameters will be Enables/Disables doing “tap” Select parameter doing � ...
20 Main menu All the Hexylon features are contained in this menu, and they will be explained in the following sections. 1. Settings Allows set all the global parameters of the meter. This feature has several tabs that will be explained below: 1.1.- Regional Sets the language, the date and the time. 1.2.- Measures Allows to set up those parameter that are commons to all the measurements: units, frequency (if real fr ...
Related Devices for Gsertel Hexylon:
BRAIN User Guide Version 6.0 triton [email protected] | www.gsertel-triton.com SMART SUPPLiES MANAGEMENT Installation instructions for the Gsertel Triton BRAIN Remote Control. It provides guidance on component replacement, wiring diagrams, maintenance.
RCS 50-RCS 100-RCS 400 Remote monitoring systems Version 9.02 User Manual Product instruction manual for the Gsertel RCS 50 Measuring Instruments. The document elaborates on device functions and device overview, error codes, user instructions.
EN Refs. 901620, 901621 User manual w w w . g s e r t e l . c o m HIGH PERFORMANCE PORTABLE METER INTENDED FOR PROFESSIONAL USERS ADVANCED FEATURES AND HIGH MEA Operation instructions for the Gsertel Hexylon Measuring Instruments. This guide includes detailed instructions for system setup, device calibration, basic operation.
Measuring Instruments: Frequently Requested PDF Instructions
PT3E-0271 FOR USERS Safety Precautions 1. Read and understand the instructions in this manual before operating this instrument. 2. Keep manual accessible at all Official operating instructions for the Riken Keiki FI-800 Measuring Instruments. It provides instructions for maintenance procedures, operation, network configuration, adjustment procedures.
O & M Manual Model PQ45P Portable pH Measurement System Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Comprehensive user handbook for the ATI Technologies PQ45P Measuring Instruments. It includes usage scenarios and component replacement, installation support, security instructions.
The Series DPGAB & DPGWB Digital Pressure Gages have a prec se ±0.5% fu sca e accuracy. The 4 d g t d g ta d sp ay w reduce the potent a for errors n read ngs Installation instructions for the Dwyer Instruments DPGAB Series Measuring Instruments. It details safety instructions and hardware instructions, installation steps, operation.
PAGE 1 IRIS MODEL S550 APPLICATION MANUAL FLAME MONITORING SYSTEM MODEL S550, S552, S556 VIEWING HEAD APPLI CATION MANUAL Operating instructions for the IRIS S552 Measuring Instruments. This guide explains technical procedures for energy usage, menu navigation, maintenance guidelines.