V2 CITY1 Manual 

Text of the manual

IL n. 170-1

EDIZ. 04/03/2009 V2 S.p.A. Corso Principi di Piemonte, 65/67 - 12035 RACCONIGI (CN) ITALY tel. +39 01 72 81 24 11 - fax +39 01 72 84 050 [email protected] - www.v2home.com CITY1 I

IMPORTANT REMARKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

CONFORMITY TO REGULATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 TECHNICAL SPECIFIC

For any installation problem please contact our Customer Service

at the number +39-0172.812411 operating Monday to Friday from 8:30 to 12:30 and from 14:00 to 18:00. V2 has the right to modify the product without previous notice; it also declines any responsibility to damage or injury to people or things caused by improper use or

Installation of control unit and safety devices must be carried out

with power disconnected. POWER SUPPLY The control unit must be fed by a 230V 50Hz (120V - 50/60Hz for the model CITY1-120V) electric line, protected by a differential magnetothermal switch complying with the law provisions in force. Connect power supply cables to term

The control unit considers two kinds of safety ribbons,

depending on the terminal to which they are connected: • Type 1 (fixed): they are mounted on walls or on other fixed obstacles that are approached by the gate doors during the opening phase. When type 1 safety ribbons operate during the gate opening phase, the control unit wi

Connect the stop switch cables between terminal 5 and 6 of the

control unit. The stop switch function can be activated by means of a remote control stored on channel 3 (see relevant instructions of MR1 receiver). The command STOP from remote is operative also if the input STOP of the terminal board is disabled. ACTIVATION INPUTS CITY1 control unit

When power is on, the control unit checks that display correctly

operates by switching on all segments for 1.5 sec. 8.8.8.8. Firmware version, e.g. Pr 2.0, will be viewed in the following 1.5 sec. Panel will be viewed upon completion of this test. The control panel represents the physical status of the terminal board contacts and of

Time menu setup

Time menus allow setting a function duration. When you enter into a time menu, the current setup value will be viewed; the display mode depends on the current value: • times being lower than one minute will be viewed as follows: each time you press UP key, current time value increases of half a second; vice versa, each time you p

Default value loading

The value of all menu items can be brought to a standard value (see final recap table) by means of only one command. There are two sets of values available: AntE Values for a two-leaf gate equipped with a lock. SCor Values for a one-leaf sliding gate without lock. After loading default values, the other menu items can be scro