Dustcontrol DC 2900c Mobile Instructions
Text of Dustcontrol DC 2900c Mobile Instructions
This Document is intended to be a condensed version of the
DC AirCube 500 manual. This is not intended to replace the
full manual for the DC AirCube 500.
Dustcontrol reserves the right to change specifications
without notice and is under no obligation to alter previously
delivered products. Dustcontrol is not responsible for errors
or omissions in this catalogue.
Table of Contents
Safety Considerations ............................................................. 4
Technical Data ........................................................................ 8
Operation ................................................................................ 9
Service ..................................................................................... 9
Accessories........................................................
Read all instructions before attempting to operate this
machine and save these instructions. Warning! When using
electric machines, basic safety precautions should always be
followed to reduce the risk of fire, electric shock and
personal injury, including the following:
1. Important!
Neither hot particles nor ignition sources are allowed to be
sucked into the unit. The machine should not be used for
explosives, unstable or pyroph
Never let the machine operate fully throttled. Always follow
the regulations pertinent to the material you are working
with i.e. asbestos. Don´t use the machine for purposes that it
isn´t intended for.
4. Body injuries
Never let the suction come in contact with parts of the body.
The strong suction effect can hurt the blood-vessels in the
skin. Don´t repair the electric components yourself. The
machine should be serviced by qualified per
7. Maintain the machine with care
Keep the machine clean and check that the hose is
undamaged and that all gaskets are tight. Follow
instructions. Keep handles dry and free from oil and grease.
8. Checking for damage
Before further use of the machine it should be carefully
checked that the machine is undamaged. If there are any
damaged parts these should be repaired by a Dustcontrol
authorized service center. If the supply cord is damaged, it
must be re
Children should be supervised to ensure that they do not
play with the appliance.
This machine is intended for commercial use only, for
example in hotels, schools, hospitals, factories, shops, offices
and rental businesses.
DC AirCube 500
HxWxL (mm/in)
380x340x495 / 15x13.3x19.5
Weight (kg/lb)
13/29
Outlet Ø (mm)
125
Max, Flow (m³/h /cfm)
500/294
Neg. Pressure (Pa/inwg)
400/1.6
Power Consumption (W)
145
Degree of Separation
(EN 60335-2-69, Class H)
99.995%
Pre-Filter “cartridge”
G3
HEPA Degree of Separation
(EN 1822-1)
HEPA H13
99.995%
*Sound Level (Speed 1/Speed 2) 45dB(A)/65dB(A)
* Sound level at 1.6 m height and 1 m distance according to DIN
EN ISO 3