Axis P3346-VE Operation & User’s Manual
| Brand: | Axis |
| Category: | Security Camera |
| Model: | P3346-VE (Operation & User’s Manual) |
| File Type: | |
| File Size: | 3.7 Mb |
| Pages: | 58 |
Text of Axis P3346-VE Operation & User’s Manual
Axis P3346-VE This manual is intended for administrators and users of AXIS P3346-VE
Fixed Dome Network Camera, and is applicable to firmware 5.40 and
later. It includes instructions for using and managing the product on
your network. Previous experience of networking will be of use when
using this product. Some knowledge of UNIX or Linux-based systems
may also be beneficial, for developing shell scripts and applications.
Later version of this document will be posted t
AXIS P3346-VE Fixed Dome Network Camera
Table of Contents
Hardware overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
Connectors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
Accessing the product
. . . . . . . . . . . . . . . . . . . . .
AXIS P3346-VE Fixed Dome Network Camera Table of Contents
Performance considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
57
4
AXIS P3346-VE Fixed Dome Network Camera Hardware overview
Hardware overview
7
6
2
1
5
4
3
1
Mounting bracket
2
Unit casing
3
Camera unit
4
Fan output connector
5
Heater. Caution! The heater may be hot.
6
Dome cover
7
Weather shield
2
1
3
4
5
6 7
8
1
Part number (P/N) & Serial number (S/N)
2
SD card slot
3
Network connector (PoE)
4
Audio out
5
Network, Status and Power LED indicators
6
Audio in
7
I/O connector
8
Control button
5
AXIS P3346-VE Fixed Dome Network Camera Hardware overview
Connectors
Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet (PoE).
Caution
Due to local regulations or the environmental and electrical conditions in which the product is to be used, a shielded
network cable (STP) may be appropriate or required. Any network cables that are routed in outdoor environments or similar
shall be shielded (STP) and intended for their specific use
AXIS P3346-VE Fixed Dome Network Camera Hardware overview
Function
Pin
Notes
Specifications
GND
1
Ground
3.3 V DC Power
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Max load = 50 mA
Digital Input
3
Connect to GND to activate, or leave floating (unconnected)
to deactivate.
0 to +40 V DC
Digital Output
4
Internal connection to ground when activated, floating
(unconnected) when deactivated. If used with an induc
AXIS P3346-VE Fixed Dome Network Camera Hardware overview
Note
• The Status LED can be configured to be unlit during normal operation. To configure, go to Setup > System Options >Ports
& Devices >LED. See the online help for more information.
• The Status LED can be configured to flash while an event is active.
• The Status LED can be configured to flash for identifying the unit. This can be done under Setup > System Options >
Maintenance.
8
AXIS P3346-VE Fixed Dome Network Camera Accessing the product
Accessing the product
To install the Axis product, refer to the Installation Guide supplied with the product.
The product can be used with most operating systems and browsers. The recommended browsers are Internet Explorer with Windows,
Safari with Macintosh and Firefox with other operating systems. See Technical Specifications, on page 55.
Note
• To view streaming video in Internet Explorer,
AXIS P3346-VE Fixed Dome Network Camera Accessing the product
Access from the Internet
Once connected, the Axis product is accessible on your local network (LAN). To access the product from the Internet you must
configure your network router to allow incoming data traffic to the product. To do this, enable the NAT-traversal feature, which
will attempt to automatically configure the router to allow access to the product. This is enabled from Setup > Syst
AXIS P3346-VE Fixed Dome Network Camera Accessing the product
Note
• The default administrator user name root is permanent and cannot be deleted.
• If the password for root is lost, the product must be reset to the factory default settings. See Reset to factory default
settings, on page 49.
Configure capture mode
Capture mode defines the maximum resolution and maximum frame rate available in the Axis product. The capture mode setting also
affects the
Axis Security Camera Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
Q1942-E |
#21T8AL: Q1942-E Security Camera Operation & user’s manual |
58 | 356 | 61 | 03-07-2026 | |
ECC80 |
Security Camera #B94597 |
4 | 929 | 205 | 29-04-2026 | |
Q1602–E |
Security Camera #GEXS87 |
130 | 996 | 210 | 13-06-2026 | |
P1375 |
User Guide: Axis P1375 (BR4S38, Upd.09-07-2026) |
22 | 258 | 50 | 09-07-2026 | |
M2025-LE |
Security Camera #KX32DE |
19 | 822 | 132 | 05-08-2026 | |
Q1765–LE |
User Manual: Axis Q1765–LE (U9A4QJ, Upd.12-04-2026) |
20 | 4.58 Mb | 419 | 93 | 12-04-2026 |
P1224–E |
#WN6D89: P1224–E Security Camera Operation & user’s manual |
52 | 1.36 Mb | 268 | 62 | 08-10-2026 |