ACV PRESTIGE Series Installation, Operating And Servicing Instructions
Read Online
Read the ACV PRESTIGE Series Installation, Operating And Servicing Instructions online using the built-in PDF viewer.
Key Pages of Document
Servicing Instructions excellence in hot water Prestige Prestige Solo 24 - 32 Prestige AquaSpeed 24 - 32 Prestige Excellence 24 - 32 05/11/2003 - 66412300 ...
2 DIRECTIONS FOR USE 3 Directions for use 3 Setting the parameters 3 DESCRIPTION 4 Description of the Prestige Solo / AquaSpeed / Excellence 4 Frost protection 4 TECHNICAL DATA 6 Natural gas version 6 Propane version 7 Pump diagram (output available in the central heating circuit) 8 Graph of the domestic hot water pressure drop 8 Domestic hot water feat ...
SAFETY INSTRUCTIONS IF YOU SMELL GAS: - Immediately shut off the gas intake - Open windows to let in air - Do not use any electrical appliances and do not switch on any swit- ches - Immediately notify your gas supplier and/or your installer General information This documentation is part of the information delivered with the appliance and must be given to the user to be kept in a safe place! An approved installer must carry out the a ...
Your system must be checked once a year by an approved installer or maintenance company. Starting the burner During operation, the burner starts automatically as soon as the boi- ler temperature drops under the required set point and it stops as soon as the boiler reaches that temperature. Control panel Heating system It can happen sometimes that the CH circuit needs to be filled. The pressure gauge on the side of the boiler screen ind ...
SOLO / AQUASPEED / EXCELLENCE Description of the specifications The Prestige is a wall-mounted condensing boiler meeting the requi- rements of the HR-Top standards in force in Belgium. The boiler is certified compliant with EC standards as a connected appliance (C13(x), C33(x), C43(x), C53, C63(x), C83(x)), but it can also be connected as an open appliance in category B23. Lining The boiler is protected by a steel lining that ...
Outlet Vent connection Water deflector tube Outlet Return Tank outer shell Inner stainless steel tank PU Insulation PU Insulation Cold water inlet pipe 3-bar safety valve, CH side Connection to the hot water system Sensor pocket for NTC 3 Connection to the hot water system CH side reserve Insulation Lining Flue ways Heat exchanger Burner Temperature regulator (MCBA) Re ...
kW 24 32 24 32 24 32 Min (intake) pressure kW 5.9 5.9 5.9 5.9 5.9 5.9 Max output 80/60°C kW 23.3 30.8 23.3 30.8 23.3 30.8 Min. output 80/60°C kW 5.8 5.8 5.8 5.8 5.8 5.8 Efficiency (high power) 80/60°C % 97 96 97 96 97 96 Efficiency (low power) 80/60°C % 98 98 98 98 98 98 Efficiency (high power) 45/30°C % 105 104 105 104 105 104 Efficiency (low power) 45/30°C % 107 107 1 ...
kW 24 30.5 24 30.5 24 30.5 Min (intake) charge kW 5.9 5.9 5.9 5.9 5.9 5.9 Max. output 80/60°C kW 23.3 29.3 23.3 29.3 23.3 29.3 Min. output 80/60°C kW 5.8 5.8 5.8 5.8 5.8 5.8 Efficiency (high power) 80/60°C % 97 96 97 96 97 96 Efficiency (low power) 80/60°C % 98 98 98 98 98 98 Efficiency (high power) 45/30°C % 105 104 105 104 105 104 Efficiency (low power) 45/30°C % ...
0 100 200 300 400 500 600 700 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 AquaSpeed Excellence Power supply available in mbar Flow in litres/hour Prestige Excellence Operating conditions at 80°C 24 32 Peak flow at 40°C (∆T = 30°C) L/10’ 175 224 Peak flow at 40°C (∆T = 30°C) L/60’ 733 835 Constant flow at 40°C (∆T = 30°C) L/hour 653 745 Peak flo ...
Min. 220 mm Min. 25 mm Min. 25 mm prestige Important: - Make sure that all air vents are unobstructed at all times. - Do not store any inflammable products in this room. - Do not store any corrosive products, such as paint, solvents, salts, chlorine products and other detergent products near the appliance. - If you smell gas, do not switch on any lights, turn off the gas tap at the meter, ventilate the rooms and c ...
10 INSTALLATION INSTRUCTIONS UK 930 107 125 80 prestige 500 A C E 120 185 250 D 315 B 380 900 400 298 59 49 A / B C / D / E 930 87,5 125 80 prestige 630 A E B 107 237 367 C 87 D 287 888 470 363,5 203,5 59 C / D A / B / E Solo / AquaSpeed — Front view Solo / AquaSpeed — Side view Excellence — Front view Excellence — Side view A = Outlet 1” Female B = Return 1” Female E = Gas 3/4” M C = Hot water 1/2” Femal ...
Excellence — Rear view ASSEMBLY PANEL 179 169 500 A C E D B 120 185 250 315 380 700 450 ...
- The connection must be completed in compliance with the NBN D51-003 standard, taking into account the local energy sup- plier’s instructions, fire regulations and regulations relative to “nui- sance” to neighbours. - The Prestige has an inbuilt gas/air ratio regulator, which makes it largely independent of the pressure drop in the air intake and flue gas extraction system. However, the maximum pressure drop for this sys ...
prestige prestige C53 C33 150 min. 120 C13 B 23 C43 C43 C33 Upward ventilation Downward ventilation Draught stabiliser ...
537D6186 3 500mm L pipe 537D6187 3 1,000mm L pipe 537D6188 4 500mm L adjustable pipe Adjustable 325 - 400 537D6189 5 135° pipe bend 537D6190 6 90° pipe bend 537D6191 7 Condensation meter and sensor 537D6192 8 Sensor 537D6193 9 Ceiling plate with removable bearing 537D6194 9 Adjustable removable bearing 537D6195 10 125 mm attachment 537D618 ...
Flush out the system before connecting it. Important It is essential that the water tank is under pressure before the central heating circuit is filled. Prestige Solo The Prestige Solo can easily be combined with all the ACV tanks using the optional kit available (ACV No. 10800079). - Remove the two cowls (A) from the boiler and connect the water tank return pipe (B) after the exchanger and the flow pip ...
opens and discharges a small quantity of water. Using a hot water expansion vessel (5 litres at least) will prevent this phenomenon and reduce water hammer. Drain the tank by turning on a hot water tap. Beware: the discharge of water and air at the same time causes the water to flow in fits and starts. INSTALLATION UK CONNECTION TO THE GAS - The Prestige is fitted with a 3/4” M connec ...
- All of the central heating system must be meticulously flushed out with clear water before the appliance is connected. - Set up the automatic air vent above the appliance close to the Prestige AquaSpeed.You will find this in the polystyrene packing. - Fit the device level, using the hook provided or the optional assembly panel for the Prestige AquaSpeed. See also the assem- bly plan on pages 10-11. - ...
local regulations in force. - The appliance is fitted with the standard network power supply cable with a lateral earth and a prong earth. Plug the cable into a wall socket connected to the earth. - The appliance is designed to be used at 230V 50Hz. - Use of the appliance can be adapted to climate conditions using the outdoor temperature sensor, available as an option. ...
19 INSTALLATION UK FUNCTIONAL DIAGRAM X1.1 X1.2 X1.4 X1.5 X1.3 X2.1 X2.2 X2.3 X2.4 X2.11 X2.12 X1.6 X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.9 X1.10 X1.11 X1.12 X1.13 X1.14 X1.15 X5.2 X5.1 X4.2 X4.3 X4.1 X3.5 X3.4 X3.3 X3.2 X3.1 X2.10 X2.8 X2.6 X2.1 X2.2 X2.3 X2.4 X2.5 X2.6 X2.7 X2.8 X2.9 X2.10 X2.11 X2.12 X2.15 X2.14 X2.13 Type 3 X3.1 X3.2 X3.3 X3.4 X3.6 X3.7 X3.9 X3.10 X3.11 X3.12 X3.8 X3.5 M 2 1 5 4 L1 N PE 3 230V P t X4 X1 X2 X3 Br B Y/Gr W B Bk R Br ...