SVSi StreamView-LR Operating Manual
| Brand: | SVSi |
| Category: | Digital Camera |
| Model: | StreamView-LR (Operating Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 27 |
Text of SVSi StreamView-LR Operating Manual
SVSi StreamView-LR Camara ultra rapida
www.pce-iberica.es
PCE Ibérica S.L.
C/ Mayor, 53 - Bajo
02500 Tobarra
Albacete-España
Tel. : +34 967 543 548
Fax: +34 967 543 542
[email protected]
www.pce-iberica.es
Manual
End-User License Agreement and Limited Product Warranty
Southern Vision Systems Software Product(s)
IMPORTANT—READ CAREFULLY: This Southern Vision Systems End-User License Agreement (“EULA”) is
a legal agreement between you (either an individual or a single legal entity) and Southern Vision Systems, Inc.
(“SVSi”). By installing, copying, downloading, accessing or otherwise using the SOFTWARE PRODUCT, you
agree to be bound by the terms of this
SVSi StreamView-LR regulations in other countries. Licensee agrees to comply strictly with all such regulations and
acknowledges that it has the responsibility to obtain licenses to export, re-export, or import Software.
Software may not be downloaded, or otherwise exported or re-exported (i) into, or to a national or resident
of Cuba, Iran, North Korea, Libya, Sudan, Syria or any country, organization or person to which the U.S.
has embargoed the export of goods; or (ii
SVSi StreamView-LR IMPORTANT SAFETY INSTRUCTIONS
DO NOT DISCARD, READ BEFORE OPERATING
Please read the safety precautions carefully before using this product. Ensure that you use the product correctly
according to the procedures described in these instructions.
The following safety precautions are intended to instruct you in the safe and correct operation of the product
and its accessories to prevent injuries or damage to yourself, other persons, and property. Please re
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. Additionally, this equipment has successfully met all of the requirements for CE
certification. These limits are designed to provide reasonable protection against harmful interference in a
commercial installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in a
TABLE OF CONTENTS
TABLE OF FIGURES ............................................................................................................................................................................. VI
1.0
SYSTEM REQUIREMENTS ........................................................................................................................................1
2.0
CAMERA CONNECTIONS.............................................................
1.0 SYSTEM REQUIREMENTS
Operating System
Windows 2000/XP Professional (recommended)
RAM
Minimum 512 MB required
1-GB (recommended for streaming to memory)
Processor
Pentium class or equivalent (1.4-GHz or faster)
Interface
Gigabit Ethernet with 9k jumbo frame support
Hard Disk Space
30 MB minimum + required video storage space (not
recommended streaming to the OS drive)
Display
1024 x 768, Color (32-bit) minimum
Lens
1” C-mount
35-mm (requires C-moun
Your StreamView-LR Gigabit Ethernet camera comes with a power adapter, operating manual, Ethernet cable,
and software CD. A host computer is required for camera set-up and for storing recorded video. StreamView-
LR is designed to record high speed video direct to either host memory or host disk array over the gigabit
Ethernet interface. The recommended minimum system requirements under section 1.0 above should allow
recording 640
SVSi StreamView-LR Figure 2 StreamView-LR network configuration auto-discovery window.
Once connected, the window below will appear allowing you to set a new IP address or to enable
DHCP.
Figure 3 Editing StreamView-LR IP configuration.
The device to which StreamView-LR is connected must have a DHCP server in order to enable DHCP.
A network router will have this capability but a laptop or desktop computer typically does not. If you
are directly connected to StreamView-LR, you must use a fixed IP address. The message below will
appear if you try to use DHCP without a DHCP server.
Figure 4 IP address incompatibility.
Once the IP address has been modified, click [OK] for the changes to
Figure 5 Setting StreamView-LR MTU size.
To set the network interface MTU size, click on [My Network Places->View Network Connections]
then select the interface to which StreamView-LR is connected. The window of Figure 6 will appear.
Next click on the [Configure] button and then the [Advanced] tab. Figure 7 will appear with a list of
attributes for that network interface. Select [Jumbo Frame] and enable to the highest value.
Figure 6 Setting
SVSi StreamView-LR Besides offering the highest video streaming performance, higher jumbo frame settings allow for
reduced host CPU usage. Some network cards (like the Netgear GA511 shown below) do not allow
specific MTU sizes to be selected – only enabled or disabled. All of the PCMCIA network cards in
Table I allow 7k jumbo frames. (Note: jumbo frame size and MTU size are equivalent.)
Figure 7 Enabling jumbo frames on the network interface.
The Buffered Frame Coun
SVSi Digital Camera Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
StreamView-LR |
User Manual: SVSi StreamView-LR (8SOC5E, Upd.14-07-2026) |
27 | 878 | 159 | 14-07-2026 |