SEFRAM 9822 Instruction Manual

Text of the manual

Data Logger Hygro-thermometer

Instruction Manual 32, rue Edouard Martel BP55 F42009 – Saint Étienne Cedex 2 E-mail: [email protected] Tel : 04 77 59 01 01 Fax : 04 77 57 23 23 Web : www.sefram.fr all-guides com

Data Logger Hygro-thermometer

1 CONTENTS TITLE PAGE 1. General Description….…………………………………………………….……………..1 2. Safety Information………………………………………………………………………... 1 3. Features……

Data Logger Hygro-thermometer

2 1. GENERAL DESCRIPTION Thank you for choosing our Data Logger Hygro Thermometer. To ensure the safety and the best performance of this instrument, we recommend you to read and follow the manual carefully before operation. Data can be stored in the meter or directly saved on a computer through PC interface. Recorded data can be

Data Logger Hygro-thermometer

3 4. SPECIFICATIONS 4-1 Probe: RP-33 Sensor type: Semi-Conductor humidity and temperature sensor Relative humidity range: 0 to 100%RH Temperature range: -20°C to 60°C (-4°F to 140°F) (253K to 333K) Dew point temperature range: -50°C to 60°C (-58°F to 140°F) (223K to 333K) Wet bulb temperature range: -20°C to 60°C (-4°

Data Logger Hygro-thermometer

4 Storage temperature: -20°C to 60°C (-4°F to 140°F) Storage humidity: 10 to 75%RH Dimensions/ Weight: Meter: 187mm(L) × 75mm(W) × 29mm(H) / Approx. 330g Probe(RP-33): 16mm Diameter x 98mm(L) Standard Accessories: Instruction manual, battery 1.5V AAA x 4 pcs, Windows software, micro USB cable, K type bead probe, carrying c

Data Logger Hygro-thermometer

5 ○ ,1 Sensor Probe ○ ,10 RECALL Saved Reading Button ○ ,2 Thermocouple Input ○ ,11 MEM Button (Set 100 Memory) ○ ,3 Display Screen ○ ,12 SETUP Button ○ ,4 Power ON/OFF Button ○ ,13 USB Interface ○ ,5 Back Light Button ○ ,14 Bluetooth Adapter ○ ,6 MAX MIN AVG Button ○ ,15 Bluetooth Compartment ○ ,7 DATA

Data Logger Hygro-thermometer

6 6. BUTTON INSTRUCTIONS 6.1 Power ON/OFF Button: Press the button to turn on the meter. Press and hold button for 3 seconds to turn off. 6.2 Backlight Button: Press to turn on the LCD backlight. This makes it easier to read in dark environment. Press again to turn off backlight. The backlight will be automatically turned of

Data Logger Hygro-thermometer

7 6.7 MAX/MIN/AVG Button: Under this mode, the unit simultaneously monitors and stores the maximum, minimum and average value in the memory. The unit will keep updating/refreshing the data. To start: (1) Press button. “ ” symbol lights up on LCD, the reading shows the maximum data. (2) Press button again to show minimum

Other Thermometer Manuals