Sealey TM101 Instructions
| Brand: | Sealey |
| Category: | Multimeter |
| Model: | TM101 (Instructions) |
| File Type: | |
| File Size: | — |
| Pages: | 5 |
Text of Sealey TM101 Instructions
Sealey TM101 professional digital multimeter ncvd
7 function
model no: tm101
thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR
this symbol indicates that a device is protected throughout by double insulation or reinforced insulation.
�
Warning! NEVER�apply�voltage�or�current�to�the�multimeter�that�exceeds�the�specified�maximum�as�shown�below:
input limits
function
maximum input
V Ac
600V dc/Ac
V dc or V Ac
600V dc/Ac,200V rms on 200mV range
mA dc
200mA 250V fast acting fuse
A dc
10A 250V fast acting fuse (30 seconds max every 15 min.
resistance,
tm101 | issue 3 12/10/16
Original Language Version
© Jack sealey limited
3. specification
function
range
resolution
Accuracy
dc Voltage
200mV
0.1mV
±(0.5% reading + 2 digits)
2000mV
1mV
20V
0.01V
200V
0.1V
±(0.8% reading + 2 digits)
600V
1V
Ac Voltage
(V Ac)
200V
0.1V
±(1.2% reading + 10 digits) (50/60Hz)
600V
1V
dc current
(A dc)
2000µA
1µA
±(1.0% reading + 2 digits)
20mA
10µA
200mA
100µA
±(1.2% reading + 2 digits)
10A
10mA
±(2.0% reading + 2 d
tm101 | issue 3 12/10/16 Original Language Version
© Jack sealey limited
4.2.
Ac VoltAGe meAsurements
�
WArninG! risk of electrocution. the probe tips may not be long enough to contact the live parts inside some 240V outlets for
appliances because the contacts are recessed deep in the outlets.
As a result, the reading may show 0 volts when the outlet actually has voltage on it. make sure the probe tips are touching the metal
contacts inside the outlet
Sealey TM101 rePlAcinG tHe BAtterY
�
Warning! to avoid electric shock, disconnect the test leads from any source of voltage before removing the battery cover.
5.1.1.
When the battery becomes exhausted or drop below the operating voltage, “BAt” will appear in the right-hand side of the
lcd display. the battery should be replaced.
5.1.2.
follow instructions for installing battery. see the Battery installation section of this manual (1.4.).