Satel ASP-105 Manual
Text of Satel ASP-105 Manual
The ASP-105 siren provides information about alarm situations by means of optical and acoustic
signaling. The siren is designed for operation within the ABAX two-way wireless system. This manual
applies to the siren with electronics version 1.3D and firmware version 3.01 (or newer).
1. Features
Acoustic signaling by means of piezoelectric transducer.
Optical signaling by means of LEDs.
Explanations for Fig. 1:
enclosure cover.
enclosure base.
battery.
piezoelectric transducer.
antenna.
Never shorten or deform the antenna.
tamper switch (tamper alarm triggered if open).
battery connector.
electronics board.
cover locking screws.
Triggering the alarm signaling
The alarm signaling is triggered:
on receiving the start signaling command – the optical and acoustic signaling can be triggered
indepen
when the control panel is running in service mode.
There can be a few seconds’ delay between starting the test mode / service mode and blocking
When the tamper signaling is blocked, the red LED is blinking every 3 seconds.
the tamper signaling.
Two sound frequencies (1450 Hz/2000 Hz) alternating within 1 second
1
2
Sound with smoothly rising and falling frequency (1450 Hz – 2000 Hz –
1450 Hz) within 1 second
3
Sound with rising fr
4. Installation and start-up
The siren must be installed on the wall, high above the floor, at a hard to access location, so as to
minimize the risk of tampering. Make sure that some free space is left above the siren (at least 2.5
cm). Otherwise, it will be impossible to replace the cover.
1. Remove the cover locking screws.
2. Lift up the enclosure cover by approx. 60º and remove it (see Fig. 3).
3. Connect the battery to the dedicated l