Grohe Avensys Installation Instructions And Operating Manual

Specifications

Brand: Grohe
Category: Bathroom Fixtures
Model: Avensys (Installation Instructions And Operating Manual), prST5fVEHEVLU
File Type: PDF
File Size: —
Pages: 12 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (12 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 22/04/2026).

Read Online

Read the Grohe Avensys Installation Instructions And Operating Manual online using the built-in PDF viewer.

Avensys Installation Instructions And Operating Manual: Key Pages of Document

Installation Instructions and Operating Guide

Please leave this document with the user after finishing installation! 95.575.131/ÄM 30 222/09.00 Avensys Exposed Single Lever Mixer 33 389 33 396 955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM ...

Table Of Contents

Installation Dimensions (mm) 1 2 33 389 33 396 kl955751.fm Seite 1 Montag, August 21, 2000 3:11 PM ...

Table Of Contents . . . . . . . . . . . . . . . . . 1

Installation Dimensions . . . . . . . . . . . . 2 Spare Parts Drawing. . . . . . . . . . . . 3 + 4 Spare Parts List. . . . . . . . . . . . . . . . . . . 5 Technical Data. . . . . . . . . . . . . . . . . . . . 6 Installation . . . . . . . . . . . . . . . . . . . . . . . 7 Exposed Installation. . . . . . . . . . . . . . . 7 Pipe And Shower Hose Connection. . . 9 Maximum Hot Water Limit Setting . . . 10 Maintenance . . . . . . . . . . . . . . . . . . . . 11 Care . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Trouble Shooting . . . . . . . . . . . . . . . . 12 Gu ...

This Avensys mixing valve is a single lever

mixer with ceramic cartridge. Lifting the lever opens water flow. Turning to the left in- creases temperature and to the right de- creases temperature. Shutting off the single lever mixer is possible in any temperature position. Hot water limitation is possible by installing the attached temperature limiter. This product is supplied with connectors to fit ø 15mm pipework. Connection should be hot left, cold right as viewed from the operating position. The product is preassembled. Plumbing Systems This single lever mixer is suitable for installation with: • Gravity-fed ...

The single lever shower mixer can be in-

stalled in two different ways. The mixing outlet can be at the bottom for use with a handshower or at the top for use with a headshower. If the pressure difference between hot and cold water supply is higher than 1 bar install attached green flow limiter (7 l/min) in the cold water connection elbow, see Fig. [1]. • Screw out connection elbow (A). • Install green flow limiter (B) with threaded ring (C) by using a 12mm socket spanner. The Single Lever Mixer is fixed to the wall via the backplate and connected to the supply pipes by a pair of elbows. The elbows are preassembl ...

6.Mark the holes in the backplate for wall-

plugs, see Fig. [4]. 7.Drill the holes (6mm) for the wallplugs (F) and fit them into the wall, see Fig. [5]. 8.Fix the backplate (D) with set screw (D1) on top or bottom to the wall with screws (G), see Fig. [6]. 9.Slide the escutcheons (H) over the supply pipes, see Fig. [7]. 10.If flow limiter is mounted in the cold water connection elbow install filter (J). 11. Slide the mixer body (E) with elbows and compression nuts loosely over the supply pipes. The body must touch the backplate. If not, check pipes for length again. 12.Fix the mixer body (E) to the back- plate (D) by tightening s ...

1.Close free outlet with plug (K), see Fig. [9].

2.Thread the outlet nipple (L) with the O-ring seal into the mixer body outlet. 3.Insert pipe and tighten outlet nipple (L). Please refer to chapter "Maximum Hot Water Limit Setting" on page 10 for limiting maximum outlet temperature. Open hot and cold water supply. Check the pipework and connections to the single lever mixer for leaks. The single lever mixer is now ready for use. Shower Hose Connection 1.Close free outlet with plug (K), see Fig. [10]. 2.Remove O-ring seal (L1). 3.Turn outlet nipple (L) 180° and fit O-ring seal (L1). 4.Thread the outlet nipple with the O-r ...

Maximum Hot Water Limit Setting

On delivery, the adjustable temperature limiter (fitted as standard) is inoperative. On applications requiring limiting the mixer opening from full hot position, the adjustable temperature limiter must be reset as de- scribed below. 1.Lever out plug (O), see Fig. [11]. 2.Remove set screw (P) with 3mm socket spanner. 3.Pull off lever (R). 4.Unscrew cap (S). 5.Remove temperature limiter (M) and, depending on the maximum water temperature required, turn clockwise (to increase temperature) or anticlock- wise (to reduce temperature) and refit, see Figs. [11] and [12]. 6.Reinstall lever as described in Fig. [11 ...

1.Shut off hot and cold water supply!

2.Lever out plug (O), see Fig. [13]. 3.Remove set screw (P) with 3mm socket spanner 4.Pull off lever (R). 5.Unscrew cap (S). 6.Pull off temperature limiter (T) and note position. 7.Remove screws (U) and detach complete cartridge (V). 8.Change either the complete cartridge (V) or seals (V1). Assemble in reverse order. Make sure that the cartridge seals (V1) engage in the grooves on the housing. Fit screws (U) and tighten evenly and alternately. Check, clean and if necessary replace parts. Only genuine GROHE replacement parts must be used. 13 O P S T U V R V1 3mm 955751.book : i95575g ...

We want to ensure that you get long-lasting

satisfaction and pleasure from your GROHE fitting. Therefore, please read the following care instructions because damage to the surface and underlying material resulting from improper treatment is not covered by our guarantee. Do not use any abrasive sponges or scou- ring agents for cleaning. We also advise not to use cleaning agents containing solvent or acid, limescale removers, household vinegar and cleaning agents with acetic acid. They are aggressive to the surface and will leave your fitting dull and scratched. As the for- mulations of commercially available cleaning agents freq ...

Our products correspond to the valid tech-

nical and water supply standards as well as the relevant approvals requirements. We guarantee them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably. Guarantee period - The guarantee is valid in private homes for 5 years from the purchase date. Proof of purchase has to be provided when making a guarantee claim. - By use in commercial or institutional appli- cations the guarantee is valid for 1 year after first use. An extension of the guarantee up to 5 y ...

Bathroom Fixtures PDF Instructions

BeBa 26151
Better Bathrooms BeBa 26151
14.04.2026 9 pages

1 WALL MOUNTED LED MIRRORED CABINET WITH SHAVER SOCKET BeBa_26151 • TOUCH SENSOR CONTROL • ADJUSTABLE STAINLESS-STEEL BUFFER HINGE • IP44 INGRESS PROTECTION • ALUMINIUM ALLOY CABINET User reference guide for the Better Bathrooms BeBa 26151 Bathroom Fixtures. It explains detailing setup, diagnostic information, compatibility information, software configuration.

LUXURY SQUARE ROD AD116441
Croydex LUXURY SQUARE ROD AD116441
22.04.2026 2 pages

Luxury Square Shower Curtain Rod Thank you for purchasing this Croydex product. Please follow the fixing and care instructions to ensure that your curtain rod is fitted safely and it retains its high quality finish. Please retain this leaflet for future refere Operation and maintenance manual for the Croydex LUXURY SQUARE ROD AD116441 Bathroom Fixtures. This guide presents installation, usage procedures, operating modes, device operation tips.

Cubista 2801
Oras Cubista 2801
28.06.2026 60 pages

Oras Cubista INSTALLATION AND MAINTENANCE GUIDE Comprehensive operating guide for the Oras Cubista 2801 Plumbing Product. It outlines the setup and device calibration, connectivity options, setup, software configuration.

DreamLine Neptune
Bath Authority DreamLine Neptune
11.04.2026 19 pages

NEPTUNE Steam Room Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower cabin. If you have any questions on this shower cabin installation - please call our technical support specialists Monday to F Official operating instructions for the Bath Authority DreamLine Neptune Bathroom Fixtures. The manual elaborates on features and operational safety, installation, connectivity options, safety features.