Raypak 185A RAYPAK REPLACEMENT INSTRUCTIONS
PC BOARD, TEMPERATURE CONTROL & SENSOR
(KIT #010253F) MODELS 185A, 265A, 335A & 405A
IMPORTANT NOTICE
These instructions are intended for use by qualified personnel specifically trained and experienced in the installation of this
type of heating equipment and related system components. Installation and service personnel may be required to be li-
censed in some states. Persons not qualified shall not attempt to instal
Raypak 185A P/N 241169 Rev 4
Effective:
10-01-10
Replaces: 09-05-08
Page 2
ACCESSING THE BOARD
1.
Turn off the power to the heater.
2.
Turn off the gas to the heater.
3.
Remove front door.
4.
Remove the four screws on the side of the heater
holding the control panel. See Fig. 1 and Fig. 2.
5.
Lay control panel forward toward you to acces the
back of the control board.
Fig. 1
REMOVE THESE SCREWS
Fig. 2
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 3
REMOVING THE CIRCUIT BOARD
Make sure the power and gas are off.
1.
Unplug all connectors from old circuit board. See
Fig. 3.
2.
Unplug keypad ribbon from old circuit board.
3.
Remove four screws as shown in Fig. 4.
4.
Remove old circuit board.
Fig. 3
2.2
UNPLUG ALL CONNECTORS
REMOVE KEYBOARD
RIBBON
Fig. 4
REMOVE MOUNTING SCREWS
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 4
DISCONNECTING IGNITION CONTROL
Make sure the power and gas are off.
1.
Unplug all wires and connectors from ignition module.
(See Fig. 5)
Note: The replacement board has an integrated ignition
module. The old ignition module can be left installed,
but will not be used.
Fig. 5
UNPLUG ALL WIRES
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 5
PROPANE HEATERS ONLY:
PREPARE NEW REPLACEMENT CONTROL PCB FOR INSTALLATION
1.
Locate the proper propane tab on the board as shown in Fig. 6.
2.
Break off tab with pliers as shown in Fig. 7 & Fig. 8.
Note:
Requirements for Propane safety time vary by
area. Check your local and state code regula-
tions
to
determine
whether
your
required
Propane safety time is 15 seconds or 90 sec-
onds.
Fig. 6
PR
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 6
Low NOx ONLY:
PREPARE NEW REPLACEMENT CONTROL PCB FOR INSTALLATION
1.
DO NOT break tab See Fig. 9 and Fig. 10.
2.
No additional wiring or connections are necessary for Low NOx oper-
ation.
Fig. 9
DO NOT
break
tab.
Fig. 10
DO NOT
break
tab.
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 7
NEW CIRCUIT BOARD & GASKET INSTALLATION USING OLD BEZEL
Note: Disregard window gasket installation if already present.
1.
Remove backing on gasket and install adhesive side on the control
panel bezel as shown in Fig. 11.
2.
Re-assemble with new board to plastic bezel using the included three
mounting screws (#6 X 3/8”) as shown in Fig. 12 & Fig. 13.
REMOVE BACKING
Fig. 11
LAY BOARD
DOWN
Fig.
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 8
REMOVING & REPLACING SENSOR
Make sure the power and gas are off.
1.
Loosen drain plug to relieve pressure in heat
exchanger. See Fig. 14.
2.
Remove five screws and access panel as
shown in Fig. 15.
3.
Route the new 3-wire sensor connector to
the board following the existing red sensor
wires.
4.
Unscrew compression nut and loosen com-
pression fitting of the old sensor. Remove
the old sensor. Se
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 9
PLASTIC SHIELD &
BRACKET INSTALLATION
Make sure the power and gas are off.
1.
Note that the plastic shield is installed under
the front bracket as pictured.
Install the
shield brackets and plastic shield using the
existing screws (#8 x ½”) and included
washers on the control panel bracket as
shown in Fig. 19.
2.
Connect the wire harnesses to the bo
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 10
INSTALLING PILOT HI TENSION WIRE
EXTENSION TO 335A:
Make sure the power and gas are off.
1.
Connect pilot wire (Side B) to new board
with new extension See Fig. 22 & Fig. 23.
2.
Connect Side A to existing pilot wire and
center protective sleeve over connection.
Side
‘A’
Side
‘B’
Fig. 22
CONNECT THIS END
TO NEW PC BOARD
SPARK LUG
CONNECT THIS END
TO EXISTING PILOT
WIRE
Fig. 23
EXISTING
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 11
DIGITAL THERMOSTAT CONTROLS
Thermostat operation
Your heater is equipped with a microprocessor-controlled thermostat that controls the pool or spa temperature by meas-
uring the temperature of the water entering the heater. It monitors the water temperature and turns the heater on when it
senses that the water temperature is below the set point. It is normal to experience small fluctuations in
P/N 241169 Rev 4 Effective:
10-01-10
Replaces: 09-05-08
Page 12
Resets board to factory default settings.
Resets faults in the History File.
Change from Fahrenheit to Celsius.
SPA setpoint maximum adjustment.
POOL setpoint maximum adjustment.
SETdef – Default Settings
Refer to step one above to access the program screen.
SETdef should appear on the screen. If not, press the Mode
button until SETdef appears on the digital display. Press