Raypak 185A RAYPAK REPLACEMENT INSTRUCTIONS

PC BOARD, TEMPERATURE CONTROL & SENSOR (KIT #010253F) MODELS 185A, 265A, 335A & 405A IMPORTANT NOTICE These instructions are intended for use by qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required to be li- censed in some states. Persons not qualified shall not attempt to instal

Raypak 185A P/N 241169 Rev 4

Effective: 10-01-10 Replaces: 09-05-08 Page 2 ACCESSING THE BOARD 1. Turn off the power to the heater. 2. Turn off the gas to the heater. 3. Remove front door. 4. Remove the four screws on the side of the heater holding the control panel. See Fig. 1 and Fig. 2. 5. Lay control panel forward toward you to acces the back of the control board. Fig. 1 REMOVE THESE SCREWS Fig. 2
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 3 REMOVING THE CIRCUIT BOARD Make sure the power and gas are off. 1. Unplug all connectors from old circuit board. See Fig. 3. 2. Unplug keypad ribbon from old circuit board. 3. Remove four screws as shown in Fig. 4. 4. Remove old circuit board. Fig. 3 2.2 UNPLUG ALL CONNECTORS REMOVE KEYBOARD RIBBON Fig. 4 REMOVE MOUNTING SCREWS
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 4 DISCONNECTING IGNITION CONTROL Make sure the power and gas are off. 1. Unplug all wires and connectors from ignition module. (See Fig. 5) Note: The replacement board has an integrated ignition module. The old ignition module can be left installed, but will not be used. Fig. 5 UNPLUG ALL WIRES
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 5 PROPANE HEATERS ONLY: PREPARE NEW REPLACEMENT CONTROL PCB FOR INSTALLATION 1. Locate the proper propane tab on the board as shown in Fig. 6. 2. Break off tab with pliers as shown in Fig. 7 & Fig. 8. Note: Requirements for Propane safety time vary by area. Check your local and state code regula- tions to determine whether your required Propane safety time is 15 seconds or 90 sec- onds. Fig. 6 PR
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 6 Low NOx ONLY: PREPARE NEW REPLACEMENT CONTROL PCB FOR INSTALLATION 1. DO NOT break tab See Fig. 9 and Fig. 10. 2. No additional wiring or connections are necessary for Low NOx oper- ation. Fig. 9 DO NOT break tab. Fig. 10 DO NOT break tab.
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 7 NEW CIRCUIT BOARD & GASKET INSTALLATION USING OLD BEZEL Note: Disregard window gasket installation if already present. 1. Remove backing on gasket and install adhesive side on the control panel bezel as shown in Fig. 11. 2. Re-assemble with new board to plastic bezel using the included three mounting screws (#6 X 3/8”) as shown in Fig. 12 & Fig. 13. REMOVE BACKING Fig. 11 LAY BOARD DOWN Fig.
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 8 REMOVING & REPLACING SENSOR Make sure the power and gas are off. 1. Loosen drain plug to relieve pressure in heat exchanger. See Fig. 14. 2. Remove five screws and access panel as shown in Fig. 15. 3. Route the new 3-wire sensor connector to the board following the existing red sensor wires. 4. Unscrew compression nut and loosen com- pression fitting of the old sensor. Remove the old sensor. Se
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 9 PLASTIC SHIELD & BRACKET INSTALLATION Make sure the power and gas are off. 1. Note that the plastic shield is installed under the front bracket as pictured. Install the shield brackets and plastic shield using the existing screws (#8 x ½”) and included washers on the control panel bracket as shown in Fig. 19. 2. Connect the wire harnesses to the bo
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 10 INSTALLING PILOT HI TENSION WIRE EXTENSION TO 335A: Make sure the power and gas are off. 1. Connect pilot wire (Side B) to new board with new extension See Fig. 22 & Fig. 23. 2. Connect Side A to existing pilot wire and center protective sleeve over connection. Side ‘A’ Side ‘B’ Fig. 22 CONNECT THIS END TO NEW PC BOARD SPARK LUG CONNECT THIS END TO EXISTING PILOT WIRE Fig. 23 EXISTING
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 11 DIGITAL THERMOSTAT CONTROLS Thermostat operation Your heater is equipped with a microprocessor-controlled thermostat that controls the pool or spa temperature by meas- uring the temperature of the water entering the heater. It monitors the water temperature and turns the heater on when it senses that the water temperature is below the set point. It is normal to experience small fluctuations in
P/N 241169 Rev 4 Effective: 10-01-10 Replaces: 09-05-08 Page 12 Resets board to factory default settings. Resets faults in the History File. Change from Fahrenheit to Celsius. SPA setpoint maximum adjustment. POOL setpoint maximum adjustment. SETdef – Default Settings Refer to step one above to access the program screen. SETdef should appear on the screen. If not, press the Mode button until SETdef appears on the digital display. Press and hold both “U