LOGICDATA HSU Operation & User’s Manual
Text of LOGICDATA HSU Operation & User’s Manual
Cable Handswitch for installation below the
desktop
HSU
Rev 3
Subject to change without notice. Errors and omissions excepted.
LOGICDATA cannot accept responsibility for incorrect operation or use of
the products other than for the intended purpose.
Under the warranty terms, LOGICDATA shall replace or repair any products
that prove defective at the time of delivery. LOGICDATA shall not assume
any further liability.
If you have any questions or
Page 2 / 11
Contents
1.
Preface................................................................................................................ 3
2.
General................................................................................................................ 3
2.1
Intended Use................................................................................................ 3
2.2
Definition ...........................................................
Page 3 / 11
1. Preface
Dear customer,
Thank you for choosing a HSU – cable-handswitch by LOGICDATA Electronic &
Software Entwicklungs GmbH. You have purchased a state-of-the-art product.
2. General
2.1
Intended Use
The HSU cable-handswitch must be used with LOGICDATA control boxes. The
control box must be installed, initially operated and functional tested by competent
personnel only. Use other than described above is only allowed with permission of
LOGI
Page 4 / 11
2.4
Package Contents
The HSU cable-handswitch package contains:
1
2
3
Figure 1: Package contents
�
HSU cable-handswitch
�
mounting plate
�
screws
Danger: Use only genuine replacement parts! Repairs must be carried
out only by a qualified service technician! If you neglect to do so you void
your warranty!
2.5
Overview
Desk upwards
Desk downwards
Display
Memory button
Position button 1
Position button 2
Position button 3
Position button 4
F
Page 5 / 11
Desk upwards
Desk downwards
Display
Figure 3: HSU-MDF-2-LD
Desk downwards
Desk upwards
Figure 4: HSU-OD-2-LD
Page 6 / 11
2.6
Handswitch Plug
Pin assignment
Handswitch connector
3
2
1
5
4
7
6
(pin alignment according to DIN 45329)
Caution: The HSU handswitch is only suitable for LOGICDATA motor
controls. To prevent damage of the unit, take care not to interchange
handswitch and motor sockets.
Colour code:
Handswitch: blue
Motor: black
3. Mounting Instructions
Mount the HSU cable-handswitch underside your desktop in an appropriate position.
Following tools are requ
Page 7 / 11
4. Connect the handswitch to the control box using the jack marked with
only!
Do not connect the handswitch plug to the motor jacks!
Caution: Unplug the power cord of the control unit while mounting the
handswitch!
Figure 5: Connect the HSU cable-handswitch to the control box (e.g. COMPACT)
Page 8 / 11
4. Functions
The HSU cable-handswitch is capable of a wide range of functions, which are
described below.
4.1
Display
The display of the HSU cable-handswitch consists of a 3 digit position and
information display.
4.2
Basic Functions
Function
Description
Note
Desk upwards
For an upward adjustment of
the desk push this button.
Push this button until the
desired height of the desk has
been reached.
The desk will continue driving
upwards until you
Page 9 / 11
4.3
Advanced Functions
4.3.1
Storing a position
Using this function you are able to store a desktop position.
Note: On initial operation all stored positions are equal to the lowest
possible desk-height (lower end position).
Note: Only one desk-height per button is allowed.
1.
Move the desk to the position you want to store.
The display reads the actual height of the desk (e.g. 73cm).
2.
Press the S button.
The display reads S –.
3.
Press
Page 10 / 11
Alternative B (using double click automatic function)
1.
Double-click the desired position button (e.g. 2)
2.
The desk automatically moves to the saved position.
If you press any button before reaching the saved position, the desk
stops and the saved position will not be reached.
The display reads the actual desk-height.
5. Technical Data
Supply voltage
5VDC ± 10%
Current consumption (average)
75 mA
Life cycle (switching cycles)
10. 000