Emerson Rosemount 1056 Quick Start Manual

File Specifications

Brand: Emerson
Category: Transmitter
Model: Rosemount 1056 (Quick Start Manual), prLMF7k/N7jD6
File Type: PDF
File Size: —
Pages: 36 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (36 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 19/06/2026).

Read Online

Read the Emerson Rosemount 1056 Quick Start Manual online using the built-in PDF viewer.

Key Pages of Document

Quick Start Guide

00825-0100-3156, Rev AA April 2019 Rosemount ™ 1056 Four-Wire, Dual-Input Intelligent Transmitter all-guide s.com ...

Your instrument purchase from Emerson is one of the finest available for your particular application.

These instruments have been designed and tested to meet many national and international standards. Experience indicates that its performance is directly related to the quailty of the installation and knowledge of the user in operating and maintaining the instrument. To ensure its continued operation to the design specifications, personne ...

Navigating the display..................................23

Startup.........................................................29 EU Declaration of Conformity.......................32 China RoHS Table.........................................34 April ...

Unpack and inspect

Procedure 1. Inspect the shipping container. If it is damaged, contact the shipper immediately for instructions. 2. If there is no apparent damage, unpack the container. Be sure all items shown on the packing list are present. If items are missing, notify Emerson immediately. 1.2 Mount Figure 1-1: Panel Mount Front View April 2019 Quick Start Guide Quick Start Guide 5 ...

Figure 1-2: Panel Mount Side View

A. Panel mount gasket B. 4X mounting brackets and screws provided with instrument C. Panel supplied by others: maximum thickness .375-in. (9.52 mm) Figure 1-3: Panel Mount Bottom View A. 6X conduit openings Quick Start Guide April 2019 6 Emerson.com/Rosemount all-guide s.com ...

Figure 1-4: Panel Mount Panel Cut-out

A. Maximum radius Note Panel mounting seal integrity (4/4X) for outdoor applications is the end user's responsibility. Figure 1-5: Wall Mount Front View A. 4X cover screw April 2019 Quick Start Guide Quick Start Guide 7 ...

Figure 1-6: Wall Mount Side View

Figure 1-7: Pipe Mount Bottom View A. Front panel B. Panel and pipe mount enclosure C. Conduit openings D. 2-in. pipe mount bracket Quick Start Guide April 2019 8 Emerson.com/Rosemount ...

General installation information

WARNING Electrical shock Electrical installation must be in accordance with the National Electric Code (ANSI/NFPA-70) and/or any other applicable national or local codes. 1. Install the transmitter with a sunshield or out of direct sunlight and areas with extreme temperatures. 2. Install the system in an area where vibrations and electromagnetic and radio frequency interference are minimized or absent. 3. Kee ...

General wiring information

The transmitter is easy to wire. It includes removable connectors and slide- out signal input boards. The front panel is hinged at the bottom. The panel swings down for easy access to the wiring locations. 3.1.1 Removable connectors and signal input boards The transmitter uses removable signal input boards and communication boards for ease of wiring and installation. You can remove each of the signal boards either part ...

In addition, you may configure any relay independently and program it to

activate pumps or control valves. As process alarms, alarm logic (high or low activation or USP*) and deadband are user-programmable. Customer-defined failsafe operation is supported as a programmable menu function to allow all relays to be energized or not energized as a default condition upon powering the transmitter. You may program the USP* alarm to activate when the conductivity ...

Use watertight fittings and hubs that comply with your requirements.

Connect the conduit hub to the conduit before attaching the fitting to the transmitter. 3.3 Power, output, and sensor connections 3.3.1 Power wiring Emerson offers three power supplies for the Rosemount™ 1056. 1. 115/230 Vac power supply (01 ordering code) 2. 24 Vdc (20-30 V) power supply (02 ordering code) 3. 85-265 Vac switching power supply (03 ordering code) AC mains (115 or 23 ...

Figure 3-3: 24 Vdc Power Supply (02 Ordering Code)

This power supply automatically detects DC power and accepts 20 Vdc to 30 Vdc inputs. Four programmable alarm relays are included. Figure 3-4: Switching AC Power Supply (03 Ordering Code) This power supply automatically detects AC line conditions and switches to the proper line voltage and line frequency. Four programmable relays are included. 3.3.2 HART® current output wiring Emerson ships all instrument ...

independent relays to the correct position on the main board using the lead

markings (+/positive, -/negative) on the board. Emerson provides male mating connectors with each unit. Figure 3-5: Current Output Wiring 3.3.3 Alarm relay wiring Emerson supplies four alarm relays with the switching power supply (85 to 265 Vac, 03 order code) and the 24 Vdc power supply (20-30 Vdc, 02 order code). Wire the relay leads on each of the independent relays to the corre ...

Figure 3-6: Alarm Relay Wiring for Rosemount™ 1056 Switching Power

Supply (03 Order Code) Table 3-1: Performance Specifications NO1 Relay 1 COM1 NC1 NO2 Relay 2 COM2 NC2 NO3 Relay 3 COM3 NC3 NO4 Relay 4 COM4 NC4 3.3.4 Wire sensor to signal boards. Procedure 1. Wire the correct sensor leads to the main board using the lead locations marked directly on the board. 2. Carefully slide the wired board fulling into the enclosure slot and take up the excess sens ...

For best EMI/RFI protection, use shielded output signal cable

enclosed in an earth-grounded metal conduit. AC wiring should be 14 gauge or greater. 3. Provide a switch or breaker to disconnect the transmitter from the main power supply. Install the switch or breaker near the transmitter and label it as the disconnecting device for the transmitter. WARNING Electrical shock Electrical installation must be in accordance with the National Electrical Code (ANS ...

Figure 3-8: Toroidal Conductivity Signal Board and Sensor Cable Leads

Figure 3-9: pH/ORP/ISE Signal Board and Sensor Cable Leads April 2019 Quick Start Guide Quick Start Guide 17 ...

Figure 3-10: Chlorine, Dissolved Oxygen, and Ozone Signal Boards and

Cable Sensor Leads Quick Start Guide April 2019 18 Emerson.com/Rosemount ...

Figure 3-11: Turbidity Signal Board with Plug-in Sensor Connection

April 2019 Quick Start Guide Quick Start Guide 19 ...

Figure 3-12: Flow/Current Input Signal Board and Sensor Cable Leads

Figure 3-13: Power Wiring for the Rosemount™ 1056 115/230 Vac Power Supply (01 Order Code) A. To main board B. Earth ground C. Neutral D. Line Quick Start Guide April 2019 20 Emerson.com/Rosemount ...