AcoustX D2 Quick Start Manual

Text of AcoustX D2 Quick Start Manual

D2 Acoustical Measurement System

Studio Version QuickStart Guide Version 1.7 AcoustX LLC 122 Calistoga Road #318 Santa Rosa, CA 95409 Tel: 707-537-1310 Fax: 707-537-1320 www.acoustx.us

Welcome to the AcoustX D2 Studio Version and win|RTA software. This

guide will provide you with an overview of setting up and connecting the hardware, and installing and running the software. The QuickStart Guide serves as a basic reference for the D2 system, but is not intended as a detailed guide to operation of the system. More detailed reference information regarding system operation and the performance of acoustical tests is provided through separate

1) The D2 uses the default settings for the Traveler with the exception of the gains of

Channels 1-4 (the mic inputs). These are set to +12 dB gain. The Studio preset should be in memory of your Traveler. 2) These controls set the microphone input gains. When using the D2 Studio Version, the gains should be set to +12 dB. The 48V switch should be to the right, enabling phantom power to the microphones. 3) The optical I/O and ADAT SYN

First install the Traveler software from the MOTU cdrom by following this procedure:

1) Insert cd into computer cd drive and click on My Computer to open the cd. 2) Open "Firewire, USB2 Audio" folder, then 32-bit firewire folder. 3) Double-click on Setup.exe. 4) Five drivers will be installed. 5) Remove the cd from the computer and reboot. 6) Connect the Traveler and then turn it on. 7) The "Found New Hardware" window will pop

Main Software Screen

Print screen Input channel Clear screen and reset to default settings Save the current measurement (Shift-Click to export as text) Exit win|RTA SPL/ Main reading window Select file to display as File A (left bar when A and B selected) Select file to display as File B (right bar when A and B selected) Filename for File B Set analyzer mode Measurement units Open Config window Set length of timed average Timed average countown Reference l

Name of theatre

Select data directory page 6 Selected data directory Defaults to "My Documents" Set CTT mode Set default units for measurements Display octave markers Show bar values when cursor is moved over a bar Enable balloon help Set length of User Average Set display for Cat. No. 566 test film (film projectors) Enable Variable X-curve (Cinema) Configuration Screen: Profile and Display Write configuration data to disk

AcoustX Measuring Instruments Owners Instructions: