- 1 -
Distance Laser Sensor
DLS-C 15 / DLS-C 30
DLS-CH 15 / DLS-CH 30
FLS-C 10 / FLS-C 30
FLS-CH 10 /FLS-CH 30
Technical Reference Manual v2.03 print rev_
Distributed and represented exclusively in the USA by:
DIMETIXUSA
www.DIMETIX-USA.com
/ionville, PA 19353
Tel: (484) 212 0636
Website: www.dimetix-usa.com
Email: [email protected]
.
TECHNICAL REFERENCE MANUAL
Table of Contents
1 Introduction...................................................................................................................................................................................................4
1.1 Product identification...........................................................................................................................................................................5
1.2 Components........................................................................................................................................................................................5
1.3 Validity.................................................................................................................................................................................................5
1.4 Measuring range..................................................................................................................................................................................6
1.5 Prevention of erroneous measurements................................................................................................................................................6
1.5.1 Rough surfaces...........................................................................................................................................................................6
1.5.2 Transparent surfaces...................................................................................................................................................................6
1.5.3 Wet, smooth, or high-gloss surfaces...........................................................................................................................................6
1.5.4 Inclined, round surfaces..............................................................................................................................................................6
1.5.5 Multiple reflections.....................................................................................................................................................................6
2 Device setup..................................................................................................................................................................................................7
2.1 Connection..........................................................................................................................................................................................7
2.2 Controlled mode..................................................................................................................................................................................8
2.2.1 Configuration.............................................................................................................................................................................8
2.2.2 Host software.............................................................................................................................................................................8
2.3 Automatic mode..................................................................................................................................................................................9
2.3.1 Configuration.............................................................................................................................................................................9
2.4 Display Mode.....................................................................................................................................................................................10
2.5 External Trigger..................................................................................................................................................................................10
2.5.1 Configuration...........................................................................................................................................................................10
3 Installation...................................................................................................................................................................................................11
3.1 Mounting...........................................................................................................................................................................................11
3.2 Device wiring.....................................................................................................................................................................................11
3.2.1 Power Supply............................................................................................................................................................................11
3.2.2 Cable connection......................................................................................................................................................................11
3.2.3 Shield and Ground....................................................................................................................................................................11
3.2.4 Controlled mode......................................................................................................................................................................12
3.2.5 Automatic mode.......................................................................................................................................................................13
3.3 Alignment of the laser beam..............................................................................................................................................................13
4 Technical data.............................................................................................................................................................................................14
4.1 Measuring accuracy...........................................................................................................................................................................14
4.2 Specifications.....................................................................................................................................................................................15
5 Electrical components..................................................................................................................................................................................16
5.1 ID switch............................................................................................................................................................................................16
5.2 Reset switch.......................................................................................................................................................................................16
5.3 Digital output.....................................................................................................................................................................................16
5.4 Digital Input.......................................................................................................................................................................................16
5.5 Analog output...................................................................................................................................................................................16
5.6 Connector..........................................................................................................................................................................................17
5.6.1 D-Sub connector.......................................................................................................................................................................17
5.6.2 Screw terminal..........................................................................................................................................................................17
6 Physical dimensions.....................................................................................................................................................................................18
7 Factory settings............................................................................................................................................................................................19
7.1 Operation...........................................................................................................................................................................................19
7.2 Communication parameters...............................................................................................................................................................19
7.3 Analog outputs..................................................................................................................................................................................19
7.4 Module ID..........................................................................................................................................................................................19
7.5 Digital output 1 (DOUT1)...................................................................................................................................................................19
7.6 Digital output 2 (DOUT2)...................................................................................................................................................................19
7.7 Digital input 1 (DI1)............................................................................................................................................................................19
7.8 User distance offset............................................................................................................................................................................19
8 Command set..............................................................................................................................................................................................20
8.1 General..............................................................................................................................................................................................20
8.1.1 Command termination ...................................................................................................................................................20
8.1.2 Module identification N............................................................................................................................................................20
8.1.3 Parameter separator.................................................................................................................................................................20
8.1.4 Set/Get Commands..................................................................................................................................................................20
8.1.5 Startup sequence......................................................................................................................................................................20
8.2 Operation commands.........................................................................................................................................................................21
TECHNICAL REFERENCE MANUAL
8.2.1 STOP/CLEAR command (sNc)....................................................................................................................................................21
8.2.2 Distance measurement (sNg)....................................................................................................................................................21
8.2.3 Signal measurement (sNm).......................................................................................................................................................21
8.2.4 Temperature measurement (sNt)...............................................................................................................................................21
8.2.5 Laser ON (sNo)..........................................................................................................................................................................22
8.2.6 Laser OFF (sNp).........................................................................................................................................................................22
8.2.7 Single sensor Tracking (sNh).....................................................................................................................................................23
8.2.8 Tracking with buffering – Start (sNf).........................................................................................................................................23
8.2.9 Read out - Tracking with buffering(sNq)...................................................................................................................................23
8.3 Configuration commands...................................................................................................................................................................24
8.3.1 Set/Get communication parameter (sNbr).................................................................................................................................24
8.3.2 Enhanced measuring Modes (sNuc)..........................................................................................................................................25
8.3.3 Set automatic mode (sNA)........................................................................................................................................................26
8.3.4 Set/Get analog output min level (sNvm)....................................................................................................................................26
8.3.5 Set/Get analog output value in error case (sNve).......................................................................................................................26
8.3.6 Set/Get distance range (sNv).....................................................................................................................................................27
8.3.7 Set/Get digital output levels (sNn).............................................................................................................................................28
8.3.8 Save configuration parameters (sNs).........................................................................................................................................28
8.3.9 Set configuration parameters to factory default (sNd)...............................................................................................................29
8.3.10 Get Software Version (sNsv)....................................................................................................................................................29
8.3.11 Get Serial Number (sNsn)........................................................................................................................................................29
8.3.12 Get device generation and type (dg).......................................................................................................................................29
8.4 Digital Input.......................................................................................................................................................................................30
8.4.1 Configure digital input (sNDI1).................................................................................................................................................30
8.4.2 Read digital input (sNRI)............................................................................................................................................................30
8.5 SSI (Synchronous serial interface)........................................................................................................................................................31
8.5.1 Change from RS422 to SSI output and back.............................................................................................................................31
8.5.2 Set/Get error value on SSI output..............................................................................................................................................31
8.6 Special User Commands.....................................................................................................................................................................32
8.6.1 Set/Get user distance offset (sNuof)..........................................................................................................................................32
8.6.2 User configured distance measurement (sNug).........................................................................................................................32
8.6.3 User-configured single sensor tracking (sNuh)...........................................................................................................................33
8.6.4 User-configured tracking with buffering – Start (sNuf)..............................................................................................................33
8.6.5 Read out – User-configured tracking with buffering (sNuq).......................................................................................................34
8.7 Error codes.........................................................................................................................................................................................35
9 Safety instructions.......................................................................................................................................................................................36
9.1 Use of the instrument........................................................................................................................................................................36
9.2 Limits to use.......................................................................................................................................................................................36
9.3 Areas of responsibility........................................................................................................................................................................37
9.4 Hazards in use....................................................................................................................................................................................37
9.5 Laser classification..............................................................................................................................................................................38
9.6 Electromagnetic compatibility (EMC)..................................................................................................................................................39
9.7 Producer Standards............................................................................................................................................................................39
9.8 Disposal.............................................................................................................................................................................................39
9.9 Labeling.............................................................................................................................................................................................40
9.10 Laser Specification............................................................................................................................................................................40
9.11 Maintenance....................................................................................................................................................................................40
9.12 Service.............................................................................................................................................................................................40
TECHNICAL REFERENCE MANUAL
1 Introduction
The DLS-C(H) and FLS-C(H) are powerful distance-measuring instruments for integration into industrial applications. They allow accurate and
contactless distance measurement over a wide range using the reflection of a laser beam:
Key features
•
Compatible with DIMETIX DLS-C(H) Laser Distance Sensor
•
Measurement range 0.05 to 500 m
•
Serial interface (RS232 and RS422)
•
SSI interface (FLS-C(H) only)
•
Connection of up to 10 modules on a single RS422 line
•
Wide range power supply (9...30VDC), heating option (24...30VDC)
•
Programmable analog output (0/4...20mA)
•
Two programmable digital outputs (DO1 and DO2)
•
Digital output for error signalization (DOE)
•
One programmable digital input (DI1)
•
ASCII protocol to control external displays
•
D-Sub connector and screw terminal joint for easy connection of DLS-C(H) / FLS-C(H)
•
IP65 (protected against ingress of dust and water)
•
4 LEDs for status signaling
•
Complementary configuration software available at Dimetix web site (www.dimetix.com)
•
Optional: Internal heater for module operation down to -40°C
•
Laser class II (<0.95mW)
•
Accessories for easy use of the sensor
CAUTION
Use of controls or adjustments or performance of procedures other than those specified in this
Technical Reference Manual may result in hazardous radiation exposure.
)
For easy startup with the DLS / FLS sensor, please use our free configuration software from our web-page:
www.dimetix.com/UtilitySW
Distance Laser Sensor
Page 4/41
Fig. 1 Standard application
Measured distance
Target
Measuring
reference
DLS-C(H)
FLS-C(H)
TECHNICAL REFERENCE MANUAL
1.1 Product identification
The product is identified by the label on the top of the sensor:
DLS-C Version with a measurement rate of up to 6 Hz
Typical Accuracy
1.5mm
3.0mm
Standard version
DLS-C 15
Part No.: 500622
DLS-C 30
Part No.: 500621
Extended temperature range
DLS-CH 15
Part No.: 500624
DLS-CH 30
Part No.: 500623
FLS-C Version with a measurement rate of up to 20 Hz
Typical Accuracy
1.0mm
3.0mm
Standard version
FLS-C 10
Part No.: 600502
FLS-C 30
Part No.: 600501
Extended temperature range
FLS-CH 10
Part No.: 600504
FLS-CH 30
Part No.: 600503
1.2 Components
1
Status LEDs
status signaling
2
15-Pin D-Sub connector
RS422, RS232, SSI , analog, digital output
3
Cable gland (M16 x 1.5mm)
for connection cable insertion
4
Cover
provides access to the screw terminal
5
Reset switch
resets the DLS-C(H) to default settings
6
Screw terminal
RS422, RS232, SSI, analog, digital output
7
ID switch
defines the module ID for RS422 operation
8
Laser beam outlet
9
Receiver optics
10
Product label
see 9.9 Labeling on page 40
1.3 Validity
This manual is valid for DLS-C(H) and FLS-C(H) devices with the following software version:
Interface software version:
0300 or later
Module software version:
0300 or later
To get the software version use the command described in 8.3.10 Get Software Version (sNsv) on page 29
Distance Laser Sensor
Page 5/41
7
6
5
9
1
8
10
1
2
1
10
4
3
TECHNICAL REFERENCE MANUAL
1.4 Measuring range
The DLS-C(H)/FLS-C(H) is an optical instrument, whose operation is influenced by environmental conditions. Therefore, the measuring range
achieved in use may vary. The following conditions may influence the measuring range:
Key
Factors increasing range
Factors reducing range
Target surface
Bright and reflective surfaces such as the target plates
(See Accessories)
Matt and dark surfaces
Green and blue surfaces
Airborne particles
Clean air
Dust, fog, heavy rainfall, heavy snowfall
Sunshine
Darkness
Bright sunshine on the target
The measurement range may be influenced by configuring different measurement modes. See 8.3.2 Enhanced measuring Modes (sNuc) on
page 25.
The DLS-C(H)/FLS-C(H) does not compensate the influence of the atmospheric environment, which may be relevant when measuring long
distances (e.g. > 150m). These effects are described in:
B.Edlen: “The Refractive Index of Air, Metrologia 2”, 71-80 (1966)
1.5 Prevention of erroneous measurements
1.5.1 Rough surfaces
On a rough surface (e.g. coarse plaster), measure against the center of the illuminated area. To avoid measuring to the bottom of gaps in the
surface use a target plate (see accessories) or board.
1.5.2 Transparent surfaces
To avoid measuring errors, do not measure against transparent surfaces such as colorless liquids (such as water) or (dust-free) glass. In case of
unfamiliar materials and liquids, always carry out a trial measurement.
)
Erroneous measurements can occur when aiming through glass panes
or if there are several objects in the line of sight.
1.5.3 Wet, smooth, or high-gloss surfaces
1
Aiming at an “acute“ angle deflects the laser beam. The DLS-C(H)/FLS-C(H) may receive a signal that is
too weak (error message 255) or it may measure the distance targeted by the deflected laser beam.
2
If aiming at a right angle, the DLS-C(H)/FLS-C(H) may receive a signal that is too strong (error message 256).
1.5.4 Inclined, round surfaces
Measurement is possible as long as there is enough target surface area for the laser spot. On irregular and round surfaces the arithmetic
average of the illuminated surfaces will be measured.
1.5.5 Multiple reflections
Erroneous measurements may occur if the laser beam is reflected by other objects than the target. Avoid any reflective object along the
measurement path.
Distance Laser Sensor
Page 6/41
TECHNICAL REFERENCE MANUAL
2 Device setup
We recommend that you carry out the configuration steps in an office before mounting the device, especially if you are not familiar with the
DLS-C(H)/FLS-C(H).
The DLS-C(H)/FLS-C(H) supports two types of operating modes:
•
Controlled mode (Host controlled)
•
Automatic mode (for use in stand-alone operation)
The first decision to be taken is the type of operating mode that will be used to transmit the distance measurement data. While the
controlled mode provides maximum flexibility and accuracy, it is often not suitable for integration into existing PLCs or analog environments.
In such cases the automatic mode might be preferred.
Influence factors
controlled mode
automatic mode
(with analog and/or digital outputs)
Accuracy
Maximum measurement accuracy
Accuracy depends on signal scaling
(see 8.3.6 Set/Get distance range (sNv) on page 27)
Flexibility
Access to full command set
Limited
Integration
Requires protocol implementation
Wiring of AO and/or DO signals
Connection
Connection of up to 10 DLS-C(H)/FLS-C(H)s to a
single RS-422 line.
Point-to-point connection
The following two sections describe the configuration of the DLS-C(H)/FLS-C(H) for the controlled and automatic modes.
2.1 Connection
To be able to configure the DLS-C(H)/FLS-C(H), it must be powered and connected to a PC. Figure 2 shows the necessary connections. On the
PC, any terminal program can be used to communicate with the module. A configuration utility is also available on the web page
www.dimetix.com.
Distance Laser Sensor
Page 7/41
Fig. 2 Connection for DLS-C(H)/FLS-C(H) configuration
DLS-C(H)
9 pin
D-Sub
Tx
Gnd
2
5
3
Tx
Rx
2
1
GND
V+
Rx
15 pin
D-Sub
9..30VDC
24..30VDC for Heating option
+
-
14,15
7,8
Default setting:
Baud:
Bit:
Parity:
Stop:
19200
7
even
1
COM1 or COM2
DLS-C(H)
FLS-C(H)
TECHNICAL REFERENCE MANUAL
2.2 Controlled mode
In controlled mode, each operation of a DLS-C(H)/FLS-C(H) is triggered by a command sent from a host system over a serial line. While a
single device can be connected to the host system using the RS232 interface, up to 10 devices can be connected to a single serial RS422 line.
The related command set is described in Chapter 8 on page 20.
2.2.1 Configuration
After connecting the module, the steps below are necessary to configure the DLS-C(H)/FLS-C(H) for the controlled interface mode.
No.
Action
Comment
Command
1
Set ID switch
Changes to the module ID are activated after a
power cycle.
Example for module 0:
Change the ID Switch to position 0
Set ID switch to position 0
Power OFF; Wait 10s; Power ON
2
Set controlled mode
Set
the
DLS-C(H)/FLS-C(H)
to
the
controlled
mode, if not already in controlled mode.
Example for module 0:
Set to controlled mode by means of the stop
command.
s0c1)
3
Set communication
parameters
If necessary, change the settings for the serial
interface.
Example for module 0:
Set serial interface to 19200 Baud, 8 Bit, no Parity
s0br+21)
Power OFF; Wait 10s; Change settings on the
host; Power ON
1) Commands are described in 8 Command set on page 20
Note:
If the communication parameters of the module are lost, please reset the configuration to the factory settings (7 Factory
settings on page 19) using the reset button (5.2 Reset switch on page 16). Please note that the ID switch must be reset
manually.
2.2.2 Host software
Host software is required for operation of the DLS-C(H)/FLS-C(H) in controlled mode. When connecting multiple devices to a single serial line
(RS422), strict Master-Slave communication must be implemented (DLS-C(H)/FLS-C(H) operates as slave). For software sample-code or
application-notes please consult our web site www.dimetix.com.
Careful testing of the host software together with the devices prior to installation is strongly recommended.
Distance Laser Sensor
Page 8/41
TECHNICAL REFERENCE MANUAL
2.3 Automatic mode
An automatic mode is provided for host-less operation of the DLS-C(H)/FLS-C(H). The analog and digital outputs are updated according to the
configuration described below as soon as the unit is powered off and on.
Analog Output
The analog output is configurable and works with two ranges:
–
0..20mA
–
4..20mA
Digital Outputs
Three digital outputs are included in the DLS-C(H)/FLS-C(H). Two are programmable, while the third is used to signal an error state of
the device.
2.3.1 Configuration
After connecting the module, the following steps are necessary to configure the DLS-C(H)/FLS-C(H) for automatic mode.
No.
Action
Comment
Command
1
Set current output range
Defines the current output range from 0 to
20mA or from 4 to 20mA.
Example for module 0:
Set current output range from 4mA to 20mA.
s0vm+11)
2
Set distance range
Defines the minimum distance (Dmin) and the
maximum distance (Dmax) for the current
range of the analog output.
Example for module 0:
Set distance range from 0m to 10m
s0v+00000000+001000001)
3
Set analog output in case of
an error
Sets the current that should be applied in case
of an error.
Example for module 0:
Set current to 0mA in case of an error.
s0ve+0001)
4
Configure digital output
Set the ON and OFF level for the digital
outputs.
Example for module 0:
DO 1: off=2000mm on=2005mm
DO 2: off=4000mm on=4005mm
s01+00020000+000200501)
s02+00040000+000400501)
5
Save settings
The changed configuration must be saved to
make it permanent.
Example for module 0:
Save settings for module 0
s0s1)
6
Set automatic mode
Set the DLS-C(H)/FLS-C(H) to the automatic
mode with the desired sample rate.
Example for module 0:
Set sample rate to fastest possible speed.
s0A+01)
1) Commands are described in 8 Command set on page 20
Note:
If the serial line settings of the module have been lost, please reset the configuration to the factory settings (7 Factory settings on
page 19) using the reset button (5.2 Reset switch on page 16). Please note that the ID switch must be reset manually.
Distance Laser Sensor
Page 9/41
TECHNICAL REFERENCE MANUAL
2.4 Display Mode
If Display Mode is enabled, the DLS-C(H)/FLS-C(H) formats the measured
distance as ASCII string, which is understood by External Displays with a
serial interface. Since the DLS-C(H)/FLS-C(H) outputs this formatted string
automatically on the serial interface after completing a measurement.
Measurement results can be displayed on an external display without an
additional controller.
For a detailed description of this mode, please contact Dimetix or your
dealer.
2.5 External Trigger
The DLS-C(H)/FLS-C(H) includes the option of triggering measurements
with an external switch or push button on Digital Input 1 (DI 1). Using
the Digital Input DI 1 disables the Digital Output DO 1.
The command to activate the external trigger option is described in 8.4
Digital Input on page 30.
2.5.1 Configuration
After connecting the DLS-C(H)/FLS-C(H), the following steps are necessary to activate the external trigger. The example shows the
configuration for triggering a single distance measurement.
No.
Action
Comment
Command
1
Activate digital input DI1
Defines the action for a trigger event on DI1.
Example for module 0:
Configure DI1 to trigger a single distance
measurement.
s0DI1+21)
5
Save settings
The changed configuration must be saved to
make it permanent.
Example for module 0:
Save settings for module 0
s0s1)
1) Commands are described in 8 Command set on page 20
Distance Laser Sensor
Page 10/41
12
13
AO
AGND
DO/DI 1
V+
7,8
9
1k
DLS-C(H)
FLS-C(H)
DLS-C(H)
FLS-C(H)
2
1
Rx
Tx
m
GND
14,15
RS232 or RS422
TECHNICAL REFERENCE MANUAL
3 Installation
3.1 Mounting
Three M4 threaded holes in the bottom of the DLS-C(H)/FLS-C(H) make it easy to mount the device.
Always obey all applicable safety regulations and never use the device outside the specifications stated under 4 Technical data on page 14.
3.2 Device wiring
3.2.1 Power Supply
For trouble-free operation use a separate power supply for the DLS-C(H)/FLS-C(H).
FLS-C, DLS-C:
9...30V, 0.5A DC
FLS-CH, DLS-CH:
24...30V, 2.5A DC
3.2.2 Cable connection
A ferrite core must be fitted to the connecting cable. Use a ferrite core with an impedance of 150 Ω to 260 Ω at 25MHz and 640 Ω to 730
Ω at 100MHz. For example you can use KCF-65 from KE Kitagawa.
3.2.3 Shield and Ground
The DLS-C(H)/FLS-C(H) contains two electrically isolated grounds, the general ground (GND) and the analog ground (AGND). GND and AGND
are connected to the housing by a RC element. Please see figure 3
Distance Laser Sensor
Page 11/41
DLS-B(H)
Fig. 3 Connection between shield and ground
Screw terminal
GND
AGND
15 pin D-Sub
GND
AGND
20nF
1M
10nF
500k
TECHNICAL REFERENCE MANUAL
3.2.4 Controlled mode
RS232
Only point-to-point communication is possible when using the RS232 interface.
Never connect multiple DLS-C(H)/FLS-C(H)s on a RS232 serial line
RS422
It is possible to connect multiple devices on a single RS422 line. To ensure proper operation, strict Master-Slave communication must be
applied. It is important, that the Master has full control of the communication and never initiates a new communication before termination of
the previous communication (answer from the DLS-C(H)/FLS-C(H) or timeout).
Ensure, that all DLS-C(H)/FLS-C(H)s are set to different ID numbers
Distance Laser Sensor
Page 12/41
Fig. 4 Point-to-point connection with RS232
DLS-B(H)
DLS-C(H)
FLS-C(H)
Fig. 5 Connecting multiple devices with RS422
DLS-C(H) / FLS-C(H)
R+
R-
T+
T-
ID switch
Position 0
A
B
A
B
Host
(PC or PLC)
Rt
Rt
5
4
6
3
14,15
Rt
Rt
7,8
V+
R+
R-
T+
T-
ID switch
Position 1
5
4
6
3
14,15
7,8
V+
R+
R-
T+
T-
ID switch
Position 9
5
4
6
3
14,15
7,8
V+
9..30VDC
24..30VDC with Heating
0V
(slave)
(slave)
(slave)
(master)
DLS-C(H) / FLS-C(H)
DLS-C(H) / FLS-C(H)
Tx
Host
(PC or PLC)
Rx
Tx
Rx
2
7,8
1
14,15
V+
9..30VDC
24..30VDC with Heating
0V
TECHNICAL REFERENCE MANUAL
3.2.5 Automatic mode
The analog interface of the DLS-C(H)/FLS-C(H) is isolated from the rest of the device. When using the analog interface, connect the analog
ground (AGND).
Make sure, that the total resistance in the analog path is lower than 500
3.3 Alignment of the laser beam
Alignment of the laser beam is often difficult when the target is far away, as the laser spot is not visible. An optional telescopic viewfinder is
available which simplifies the alignment significantly.
Distance Laser Sensor
Page 13/41
Fig. 6 Connection of an instrument and a PLC
DLS-C(H)
FLS-C(H)
Analog Input
0..20mA
12
14,15
13
Digital Input
24V=
9..30VDC
24..30VDC for Heating Option
0V
PLC
AO
AGND
DO 1
DO 2
V+
GND
7,8
9
10
TECHNICAL REFERENCE MANUAL
4 Technical data
4.1 Measuring accuracy
The measuring accuracy corresponds to the ISO-recommendation ISO/R 1938-1971 with a
statistical confidence level of 95.4% (i.e. ± twice the standard deviation σ, refer to
diagram on the right). The typical measuring accuracy relates to average conditions for
measuring. It is ±1.0mm for the FLS-C(H) 10, ±1.5mm for the DLS-C(H) 15 and ± 3.0mm
for the DLS-C(H)/FLS-C(H) 30 valid in the tracking mode.
Maximum deviation may occur under unfavorable conditions such as bright sunlight or
when measuring to poorly reflecting or very rough surfaces. Measuring accuracy may
deteriorate by approximately ±0.02mm/m for distances above 30m.
The DLS-C(H)/FLS-C(H) does not compensate changes of atmospheric environment. These
changes can influence the accuracy if measuring long distances (>150m) under conditions
very different from 20°C, 60% relative humidity and 953 mbar air pressure. The influences
of the atmospheric environment are described in
B.Edlen: “The Refractive Index of Air, Metrologia 2”, 71-80 (1966)
Distance Laser Sensor
Page 14/41
99.7%
95.4%
TECHNICAL REFERENCE MANUAL
4.2 Specifications
Typical measuring accuracy for
DLS-C 15 / DLS-CH 15 1)
DLS-C 30 / DLS-CH 30 1)
FLS-C 10 / FLS-CH 10 1,3)
FLS-C 30 / FLS-CH 30 1,3)
± 1.5 mm @ 2σ
± 3.0 mm @ 2σ
± 1.0 mm @ 2σ
± 3.0 mm @ 2σ
Accuracy of the analog output
DLS-C(H)
FLS-C(H)
0.2% programmed span (8.3.6 Set/Get distance range (sNv) on page 27)
0.1% programmed span (8.3.6 Set/Get distance range (sNv) on page 27)
Typical Repeatability for
DLS-C 15 / DLS-CH 15 1)
DLS-C 30 / DLS-CH 30 1)
FLS-C 10 / FLS-CH 10 1)
FLS-C 30 / FLS-CH 30 1)
± 0.4 mm @ 2σ
± 0.5 mm @ 2σ
± 0.3 mm @ 2σ
± 0.5 mm @ 2σ
Smallest unit displayed
0.1 mm
Measuring range on natural surfaces
0.05 m to approx. 65 m
Measuring range on orange (reflective) target plate DLS-C(H)
FLS-C(H)
Approx. 25 m to 150 m
Approx. 0.5 m to 500 m
Measuring reference
from front edge (See 6 Physical dimensions)
Diameter of laser spot at target at a distance of
4mm @ 5m
8mm @ 10m
15mm @ 30m
Time for a measurement
Single measurement:
DLS-C(H) / FLS-C(H) 3)
Tracking:
DLS-C(H) 3)
FLS-C(H) 3)
Typical: 0.3 s to 4 s
Typical: 0.15 s to 4 s
Typical: 50 ms to 4 s
Light source
Laser diode 620-690 nm (red)
IEC 60825-1:2007; Class 2
FDA 21CFR 1040.10 and 1040.11
Beam divergence:0.16 x 0.6 mrad
Pulse duration: 0.45x10-9 s
Maximum radiant power: 0.95 mW
Laser Life Time
typical 50'000h @ 20°C
ESD
IEC 61000-4-2
EMC
EN 61000-6-4
EN 61000-6-2
Power supply
9 ... 30V DC 0.6A for DLS-C / FLS-C
24 ... 30V DC 2.5A for DLS-CH /FLS-CH(Heating option)
Dimensions
150 x 80 x 55 mm
Temperature range during operation 2)
DLS-C 15 / DLS-C 30
DLS-CH 15 / DLS-CH 30
-10 °C to +50 °C
-40 °C to +50 °C
Temperature range during storage
-40 °C to +70 °C
Degree of Protection
IP65; IEC60529 (protected against ingress of dust and water)
Weight
DLS-C, FLS-C:
690 g
DLS-CH, FLS-CH:
720 g
Standard interface
1 serial asynchronous interface RS232
1 serial asynchronous interface RS422
1 SSI (only FLS-C(H))
1 programmable analog output 0/4 .. 20mA
2 programmable digital outputs
1 programmable digital input
1 digital output for error status
1) See 4.1 Measuring accuracy on page 14.
2) In case of permanent continuous measurement (tracking mode) the max. temperature is reduced to 45°C
3) Accuracy and measurement speed depend on configuration (See 8.3.2 Enhanced measuring Modes (sNuc) on page 25)
Distance Laser Sensor
Page 15/41
TECHNICAL REFERENCE MANUAL
5 Electrical components
5.1 ID switch
This switch is used to set the module ID and can be set from 0 to 9. The default setting is 0.
5.2 Reset switch
To reset the module to factory settings do the following:
•
Change ID Switch to position 0
•
Switch OFF the power for the module
•
Press the reset button and keep it pressed
•
Switch on the power for the module
•
Keep the reset button pressed until all LEDs on the module are illuminated
•
Release the reset button
•
Switch the power OFF and wait 5 seconds
•
Switch on the power and wait until the green power LED is on
5.3 Digital output
The DLS-C(H)/FLS-C(H) contain two digital outputs for level monitoring (DO 1 and DO 2) and one digital
output for error signalization (DO E). These outputs are open drain outputs as shown in figure 7 and
can drive up to 200mA. Maximum switching voltage is 30V DC. In the ON state, the FET transistor is
electro conductive.
5.4 Digital Input
The Digital Output (DO 1) can be configured as a Digital Input (DI 1). This is useful for triggering measurements by means of an external
switch or push button. Please refer to chapter 8.4 Digital Input on page 30.
Low Level is:
U DI1 < 2VDC
High Level is:
U DI1 > 9VDC and U DI1 < 30VDC
5.5 Analog output
The analog output of the DLS-C(H)/FLS-C(H) is a current source (0..20mA or 4..20mA). It is capable of driving loads up to 500 Ω.
eDist=Accuracy DeviceMaxDistConf−MinDist Conf∗Accuracy AO
100
eDist
Total error in mm
MaxDistConf
Configured max Distance in mm
AccuracyGerät
Device accuracy in mm
MinDistConf
Configured min Distance in mm
AccuracyAO
Accuracy of the analog output in %
Example:
Device accuracy
Min. Distance
Max. Distance
Accuracy analog output FLS
Total error
DLS-C(H) 30
±3 mm
0 mm
10'000 mm
±0.1%
3mm10000−0∗0.1
100
=±13mm
)
The stated errors include all possible errors as Temperature drift, linearity, surface color and measurement distance.
The best accuracy of ±1.5 mm for the DLS-C(H) 15 and ±1 mm for the FLS-C(H) 10 can only be
achieved by using the digital interfaces (RS-232, RS-422 or SSI)
Distance Laser Sensor
Page 16/41
Fig. 7 Open drain output
DOUT
On
Reset switch
ID switch
TECHNICAL REFERENCE MANUAL
5.6 Connector
5.6.1 D-Sub connector
Pin
Designator
Description
1
Rx
RS232 receive line
2
Tx
RS232 send line
3
T-
RS422 send line negative
SSI data output negative (Only for FLS-C and if configured for SSI)
4
T+
RS422 send line positive
SSI data output positive (Only for FLS-C and if configured for SSI)
5
R-
RS422 receive line negative
SSI clock input negative (Only for FLS-C and if configured for SSI)
6
R+
RS422 receive line positive
SSI clock input positive (Only for FLS-C and if configured for SSI)
7
V+
8
V+
DC Power
+ 9V…+30V for DLS-C / FLS-C
+24V…+30V for DLS-CH / FLS-CH (Heating option)
9
DO 1
Digital output 1 (Open Drain) or Digital input 1
10
DO 2
Digital output 2 (Open Drain)
11
DO E
Digital output for error signalization (Open Drain)
12
AGND
Analog ground
13
AO
Analog output (0/4..20mA)
14
GND
Ground line
15
GND
Ground line
5.6.2 Screw terminal
Designator
Description
R+
RS422 Receive line positive
SSI clock input positive (Only for FLS-C and if configured for SSI)
R-
RS422 Receive line negative
SSI clock input negative (Only for FLS-C and if configured for SSI)
T+
RS422 Send line positive
SSI data output positive (Only for FLS-C and if configured for SSI)
T-
RS422 Send line negative
SSI data output negative (Only for FLS-C and if configured for SSI)
Tx
RS232 Transmit line
Rx
RS232 Receive line
AGND
Analog ground
AO
Analog output (0/4..20mA)
DO E
Digital output for error signalization (Open Drain)
DO 2
Digital output 2 (Open Drain)
DO 1
Digital output 1 (Open Drain) or Digital input 1
GND
Ground line
V+
Power DC
+9V...+30V DLS-C / FLS-C
+24...+30V DLS-CH / FLS-CH (Heating option)
Distance Laser Sensor
Page 17/41
No.1
1
9
15
8
TECHNICAL REFERENCE MANUAL
6 Physical dimensions
All dimensions in mm
Distance Laser Sensor
Page 18/41
37.3
12.2
28.0
150.0
38.5
88.5
Measuring reference
=
=
3 x M4 x 5
54.0
80.0
M16 x 1.5
40.0
=
=
152.5
80.0
Laser Beam
TECHNICAL REFERENCE MANUAL
7 Factory settings
7.1 Operation
Mode:
Controlled Mode
7.2 Communication parameters
Baud:
19200
Data bit:
7
Parity:
Even
Stop bit:
1
(Setting 7)
7.3 Analog outputs
Min output:
4mA
Range min:
0m
Range max:
10m
Error output:
0mA
7.4 Module ID
ID Number:
0
7.5 Digital output 1 (DOUT1)
ON:
2m + 5mm
=
2005mm
OFF:
2m - 5mm
=
1995mm
7.6 Digital output 2 (DOUT2)
ON:
1m – 5mm
=
995mm
OFF:
1m + 5mm
=
1005mm
7.7 Digital input 1 (DI1)
Inactive, configured as output
7.8 User distance offset
User distance offset = 0mm
Distance Laser Sensor
Page 19/41
TECHNICAL REFERENCE MANUAL
8 Command set
8.1 General
8.1.1 Command termination
All commands for the DLS-C(H)/FLS-C(H) are ASCII based and terminated with .
8.1.2 Module identification N
Since the module can be addressed with the ID switch, the ID is represented in the commands by N. At the location of the N insert the
Module ID.
8.1.3 Parameter separator
The command syntax uses the '+' sign as parameter separator. The '+' sign can be replaced by the minus '-' sign if applicable by the
command.
8.1.4 Set/Get Commands
All configuration commands that are used to set configuration values can also be used to read the currently set value by omitting the
parameter. The command syntax is described as follows:
Set Command
Get Command
Command
sNuof+xxxxxxxx
sNuof
Return successful
gNuof?
gNuof+xxxxxxxx
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module ID
xxxxxxxx
Offset in 1/10 mm; + positive / - negative
zzz
Error code
8.1.5 Startup sequence
After power on, the DLS-C(H)/FLS-C(H) does all the initializations and sends a start sequence gN?. On this sequence, the N stands for the
Module ID. After sending this start sequence, the DLS-C(H)/FLS-C(H) is ready to use.
Distance Laser Sensor
Page 20/41
TECHNICAL REFERENCE MANUAL
8.2 Operation commands
8.2.1 STOP/CLEAR command (sNc)
Stops the current execution and resets the status LEDs as well as the digital outputs.
Command
Command
sNc
Return successful
gN?
Return Error
gN@Ezzz
Parameters
N
Module ID
zzz
Error code
8.2.2 Distance measurement (sNg)
Triggers simple measurement of distance. Each new command cancels an active measurement.
Command
Command
sNg
Return successful
gNg+xxxxxxxx
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
Distance in 1/10 mm
zzz
Error code
8.2.3 Signal measurement (sNm)
Signal measurement can be done continuously or with a single measurement. The signal strength is returned as a relative number in the
range of 0 to 8 millions.
The value for the signal strength is just an approximate value, it differs from device to device and also depends on environment conditions.
Command
Command
sNm+c
Return successful
gNm+xxxxxxxx
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
c
0: single measurement
1: repetitive measurements ! attention, use only with one sensor
xxxxxxxx
Signal strength (range 0.. 8 millions)
zzz
Error code
8.2.4 Temperature measurement (sNt)
Triggers measurement of the temperature inside the sensor.
Command
Command
sNt
Return successful
gNt+xxxxxxxx
Return Error
gN@Ezzz
Parameters
N
Module ID
xxxxxxxx
Temperature in 0.1°C
zzz
Error code
Distance Laser Sensor
Page 21/41
TECHNICAL REFERENCE MANUAL
8.2.5 Laser ON (sNo)
Switches laser the beam ON for easy adjustment.
Command
Command
sNo
Return successful
gN?
Return Error
gN@Ezzz
Parameters
N
Module ID
zzz
Error code
8.2.6 Laser OFF (sNp)
Switches the laser OFF.
Command
Command
sNp
Return successful
gN?
Return Error
gN@Ezzz
Parameters
N
Module ID
zzz
Error code
Distance Laser Sensor
Page 22/41
TECHNICAL REFERENCE MANUAL
8.2.7 Single sensor Tracking (sNh)
Triggers continuous measurement of the distance. The measurements are made as fast as possible (Measurement speed depends on target
conditions) This command is not to be used with more then one DLS-C(H)/FLS-C(H) on a RS-232/RS-422 line. The measurements are
continued until the STOP/CLEAR command is issued. The status LEDs and the digital outputs are updated corresponding to the new
measured distance.
Never use this command if more than one module is connected to the RS232/RS422 line
Command
Command
sNh
Return successful
gNh+xxxxxxxx
Return Error
gN@Ezzz
Parameters
N
Module ID
xxxxxxxx
Distance in 0.1mm
zzz
Error code
8.2.8 Tracking with buffering – Start (sNf)
Triggers continuous measurement of the distance with internal buffering in the module (buffer for one measurement). The rate of
measurements is defined with the sampling time. If the sampling time is set to zero, the measurements are executed as fast as possible
(Measuring speed depends on target conditions). The last measurement can be read out from the module with the command sNq. The
measurements are continued until the 'sNc' command is issued.
Set Command
Get Command
Command
sNf+xxxxxxxx
sNf
Return successful
gNf?
gNf+xxxxxxxx
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module ID
xxxxxxxx
Sampling rate in 10ms (if 0 -> max possible rate)
zzz
Error code
8.2.9 Read out - Tracking with buffering(sNq)
After starting “tracking with buffering” with the command sNf, the last measurement can be read out from the module with the
command sNq.
Command
Command
sNq
Return successful
gNq+xxxxxxxx+c
Return Error
gN@Ezzz+c
Parameters
N
Module ID
xxxxxxxx
Distance in 0.1mm
c
0 = no new measurement since last sNq command
1 = one new measurement since last sNq command, not overwritten
2 = more than one measurement since last sNq command, overwritten
zzz
Error code
Distance Laser Sensor
Page 23/41
TECHNICAL REFERENCE MANUAL
8.3 Configuration commands
8.3.1 Set/Get communication parameter (sNbr)
Sets the communication parameters for the serial interface.
This command saves all configuration parameters to Flash.
The changed baud rate is activated after the next power on.
Bold = default parameters (first use or after reset)
Command
Command
sNbr+y
Return successful
gN?
Return Error
gN@Ezzz
Parameters
N
Module ID
y
Defines the new settings
% Baud rate
Data bit
Parity
%
Baud Rate
Data bit
Parity
0
1200
8
N
6
9600
7
E
1
9600
8
N
7
19200
7
E
2
19200
8
N
8
38400
8
N
3
1200
7
E
9
38400
7
E
4
2400
7
E
10
115200
8
N
5
4800
7
E
11
115200
7
E
Distance Laser Sensor
Page 24/41
TECHNICAL REFERENCE MANUAL
8.3.2 Enhanced measuring Modes (sNuc)
Multiple measuring modes available in the FLS-C measuring devices meet different requirements for various applications. With these
measuring modes measuring rate and accuracy can be optimized for special requirements.
The FLS-C measuring device has with factory settings an accuracy of ±1 mm (FLS-C(H) 10) respectively ±3 mm (FLS-C(H) 30) at 2σ. Measuring
rate depends on environmental conditions such as target surface, distance, background light (e.g. sun light), etc. Good environmental
condition increase measuring rate (e.g. white target surface or orange reflective target plate and dark environment).
Measuring Mode overview
Mode
Measuring
rate
σ
Typical accuracy @ 2
Characteristics
Application examples
FLS-C(H) 10 FLS-C(H) 30
Normal
(factory
settings)
max. 10 Hz1)
±1 mm
±3 mm
Measuring range on natural surface: typical 65 m
Various
Fast
max. 20 Hz1)
±2 mm
±6 mm
Increased measuring rate up to 20 Hz.
Positioning applications:
Warehouse, Crane, etc.
Precise
max. 6 Hz1)
~±0.8 mm
~±2.4 mm
Increased accuracy of ±0.8 mm
Surveying applications, short
range applications etc.
Natural
surface
~0.3Hz @
up to
approx.
80m
~±5 mm @
up to
approx.
80m
~±15 mm @
up to
approx.
80m
Increased measuring range on natural surfaces:
typical 80 meters
Measuring against far away
natural surfaces or bad reflective
surfaces such as black synthetic
granules, etc.
1) Good environmental conditions (e.g. white target surface or orange reflective target plate and dark environment).
Configuration command
The configuration command sNuc is applied to the special user commands as well to the standard
commands.
Command
Get Command
Command
sNuc+0+x
sNuc
Return successful
gNuc+00000000+xxxxxxxx
gNuc+xxxxxxxx+yyyyyyyy
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module number (0..9)
x
measuring mode
0:
Normal
1:
Fast
2:
Precise
3:
Natural surface
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
Distance Laser Sensor
Page 25/41
TECHNICAL REFERENCE MANUAL
8.3.3 Set automatic mode (sNA)
This command activates the automatic mode of the DLS-C(H)/FLS-C(H). It triggers continuous measurement of the distance. The analog,
digital and SSI outputs are updated according to the measured distance values. The sampling time defines the measurement rate. If the
sampling time is set to zero, the measurements are executed as fast as possible (depending on target conditions).
The automatic mode is active until the STOP/CLEAR command (sNc') is issued.
The operating mode is stored in the DLS-C(H)/FLS-C(H) and activated immediately. This mode is also
activated after next power ON.
Internally, “tracking with buffering” is started (command sNf). Therefore, the last measurement can
also be read out from the module with the command sNq.
Command
Command
sNA+xxxxxxxx
Return successful
gNA?
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
Sampling time in 10 ms (if 0 -> max. possible rate)
zzz
Error code
8.3.4 Set/Get analog output min level (sNvm)
This command sets the minimum analog output current level (0 or 4 mA).
Set Command
Get Command
Command
sNvm+x
sNvm
Return successful
gNvm?
gNvm+x
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module number (0..9)
x
Minimum output for analog out
0: Minimum current is 0 mA
1: Minimum current is 4 mA
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
8.3.5 Set/Get analog output value in error case (sNve)
This command sets the analog output current level in mA in case of an error. This level can be lower than the minimum level set in 8.3.4
Set/Get analog output min level (sNvm).
Set Command
Get Command
Command
sNve+xxx
sNve
Return successful
gNve?
sNve+xxx<
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module number (0..9)
xxx
Value in case of an error in 0.1mA
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
Distance Laser Sensor
Page 26/41
TECHNICAL REFERENCE MANUAL
8.3.6 Set/Get distance range (sNv)
Sets the minimum and maximum distances corresponding to the minimum and maximum analog output current levels.
0...20mA
4...20mA
Aout=DIST −Dmin
Dmax−Dmin
∗20mA
Aout=DIST −Dmin
Dmax−Dmin
∗16mA4mA
Aout
Analog current output
DIST
Actual measured distance
Dmin
Distance programmed for the minimum output current
Dmax
Distance programmed for the maximum output current
Set Command
Get Command
Command
sNv+xxxxxxxx+yyyyyyyy
sNv
Return successful
gNv?
gNv+xxxxxxxx+yyyyyyyy
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
Minimum distance in 1/10 mm corresponding to 0mA / 4mA
yyyyyyyy
Maximum distance in 1/10 mm corresponding to 20mA
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
Distance Laser Sensor
Page 27/41
TECHNICAL REFERENCE MANUAL
8.3.7 Set/Get digital output levels (sNn)
Sets the distance levels at which the digital outputs are switched ON and OFF with a hysteresis.
Two different situations are possible:
ON level > OFF level
The ON level of the hysteresis is larger than the OFF level. With an increasing
distance, the digital output is switched on (open drain output is closed) when the
distance exceeds the ON level. With a decreasing distance, the digital output is
switched off (open drain output is open) when the distance falls below the OFF
level.
ON level < OFF level
The ON level of the hysteresis is smaller than the OFF level. With a decreasing
distance, the digital output is switched on (open drain output is closed) when the
distance falls below the ON level. With an increasing distance, the digital output
is switched off (open drain output is open) when the distance exceeds the OFF
level.
Set Command
Get Command
Command
sNn+xxxxxxxx+yyyyyyyy
sNn
Return successful
gNn?
gNn+xxxxxxxx+yyyyyyyy
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module number (0..9)
n
Digital output port (1 or 2)
xxxxxxxx
Distance ON level in 1/10 mm for switching digital output ON
yyyyyyyy
Distance OFF level in 1/10 mm for switching digital output OFF
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
8.3.8 Save configuration parameters (sNs)
This command saves all configuration parameters, which are set by the commands above. The parameters are written to the Flash Memory.
Command
Command
sNs
Return successful
gNs?
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
zzz
Error code
Distance Laser Sensor
Page 28/41
DO
Distance
Off
On
0
closed
open
DO
Distance
Off
On
0
closed
open
TECHNICAL REFERENCE MANUAL
8.3.9 Set configuration parameters to factory default (sNd)
This command restores all configuration parameters to their factory default values. The parameters are written to the Flash Memory and
therefore permanently saved.
The communication parameters are also reset to factory settings.
Command
Command
sNd
Return successful
gN?
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
zzz
Error code
8.3.10 Get Software Version (sNsv)
Retrieves the software version of the DLS-C(H)/FLS-C(H).
Command
Command
sNsv
Return successful
gNsv+xxxxyyyy
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
xxxx
Internal measuring module software version number
yyyy
Interface software version
zzz
Error code
8.3.11 Get Serial Number (sNsn)
Retrieves the serial number of the DLS-C(H)/FLS-C(H).
Command
Command
sNsn
Return successful
gNsn+xxxxxxxx
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
Serial number of the device
zzz
Error code
8.3.12 Get device generation and type (dg)
This command returns the device type, generation and current communication settings.
Works only from device generation C on.
Command
Command
dg
Return successful
gNdg+xxx+yz?
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
xxx
Bit coded number to identify the device:
0x53 (83)
DLS-C / FLS-C
y
(additional internal information)
z
Communication settings (see command sNbr+C)
zzz
Error code
Distance Laser Sensor
Page 29/41
TECHNICAL REFERENCE MANUAL
8.4 Digital Input
The following commands configure the terminal DO1. This port can also be used as digital input. For safety reasons, always use a resistor to
protect the connection terminal.
8.4.1 Configure digital input (sNDI1)
The digital output 1 of the DLS-C can also be used as digital input. Its state can be read or trigger a configurable action. Use the following
command to configure the behavior of the digital input.
On active digital input, the digital output function of DO1 is deactivated
Set Command
Get Command
Command
sNDI1+xxxxxxxx
sNDI1
Return successful
gNDI1?
sNDI1+xxxxxxxx
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
0:
Digital input inactive (DO1 active)
1:
activate the digital input to read out its state with the command
8.4.2 Read digital input (sNRI).
2:
Trigger Distance measurement (sNg)
3:
Start/Stop Single sensor Tracking (sNh)
4:
Start/Stop Tracking with buffering (sNf)
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
8.4.2 Read digital input (sNRI)
Displays the state of the digital input, if the input is not inactive. (Necessary configuration of the digital input: sNDI1+1)
Command
Command
sNRI
Return successful
gNRI+x
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
x
0: Input Off (Signal Low)
1: Input On (Signal High)
zzz
Error code
Distance Laser Sensor
Page 30/41
DO/DI 1
V+
7,8
9
1k
DLS-C(H)
FLS-C(H)
TECHNICAL REFERENCE MANUAL
8.5 SSI (Synchronous serial interface)
The SSI Interface is only implemented in the FLS type. Connect the device by RS232 to do the configuration and use the following commands
to activate the SSI interface. The application note “SSI Interface” contains all detailed information to operate the SSI Interface.
8.5.1 Change from RS422 to SSI output and back
If the SSI interface should be used at the same port where normally the RS422 resides, it can be switched.
Set Command
Get Command
Command
sNSSI+c
sNSSI
Return successful
gNSSI?
gNSSI+c
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module ID
c
0: switch to (or stay in) RS 422 mode
1: switch to (or stay in) SSI mode
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
8.5.2 Set/Get error value on SSI output
In measuring error case, the SSI output will have the value, which is stored as the SSI error value.
To change it, the sNSSIe command can be used: The value can be in the range [0;16777215].
This value will only be available until the next power OFF. To keep it, use the sNs command.
Set Command
Get Command
Command
sNSSIe+xxxxxxxx
sNSSIe
Return successful
gNSSIe?
gNSSIe+xxxxxxxx
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module ID
xxxxxxxx
A value within 0 and 16777215.
zzz
Error code
Configuration parameters need to be saved (See 8.3.8 Save configuration parameters (sNs) on page 28)
Distance Laser Sensor
Page 31/41
TECHNICAL REFERENCE MANUAL
8.6 Special User Commands
The special user commands are user configurable and are an extension to the standard commands. Use these commands carefully and only if
you really understand their impact.
The syntax of the user commands differ to the standard commands as follows:
Standard Commands:
sNxx
User Commands:
sNuxx
The user configuration parameters influence the result of the user commands. A gain and offset may be applied to the measurement result
and the output format may be configured.
8.6.1 Set/Get user distance offset (sNuof)
The user can set an individual overall offset correction for all distance measurement commands in this 'Special User Command' section. The
standard distances measurement commands are not involved.
Set Command
Get Command
Command
sNuof+xxxxxxxx
sNuof
Return successful
gNof?
gNuof+xxxxxxxx
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module ID
xxxxxxxx
Offset in 1/10 mm; + positive / - negative
zzz
Error code
8.6.2 User configured distance measurement (sNug)
Triggers simple distance measurement, similar to the command 8.2.2 Distance measurement (sNg) on page 21. This command returns the
distance corrected with the user offset as set with the command 8.6.1 Set/Get user distance offset (sNuof). Each new command cancels an
active measurement.
This command takes the user distance offset into account
Command
Command
sNug
Return successful
gNug+xxxxxxxx
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
Distance in 0.1mm
zzz
Error code
Distance Laser Sensor
Page 32/41
TECHNICAL REFERENCE MANUAL
8.6.3 User-configured single sensor tracking (sNuh)
Triggers continuous measurement of the distance and outputs the result immediately to the serial interface. The distance measurement is
executed as fast as possible (depending on target conditions). The measured distance is corrected with the user offset as set with the
command 8.6.1 Set/Get user distance offset (sNuof). The measurements are continued until the stop/clear command (sNc) is issued. Each
measurement updates the status LED's and all outputs.
This command takes the user distance offset into account
Never use these commands if more than one module is connected to the RS232/RS422 line
Command
Command
sNuh
Return successful
gNuh+xxxxxxxx
Return Error
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
Distance in 0.1mm
zzz
Error code
8.6.4 User-configured tracking with buffering – Start (sNuf)
Triggers continuous measurement of the distance with internal buffering in the module (buffer for one measurement). The measured
distance is corrected with the user offset as set with the command 8.6.1 Set/Get user distance offset (sNuof). Define the rate of
measurements with the sampling time. If the sampling time is set to zero, the measurements are executed as fast as possible. The last
measurement can be read out from the module with the command sNuq. The measurements are continued until the stop/clear command
(sNc) is issued.
This command takes the user distance offset into account
Set Command
Get Command
Command
sNuf+xxxxxxxx
sNuf
Return successful
gNuf
gNuf+xxxxxxxx
Return Error
gN@Ezzz
gN@Ezzz
Parameters
N
Module number (0..9)
xxxxxxxx
Sampling time in 10ms (if 0 -> use max. possible sample rate)
zzz
Error code
Distance Laser Sensor
Page 33/41
TECHNICAL REFERENCE MANUAL
8.6.5 Read out – User-configured tracking with buffering (sNuq)
After starting “User-configured fast tracking with buffering” with the command sNuf, the last measurement can be read out from the DLS-
C(H)/FLS-C(H).
This command takes the user distance offset into account
Command
Command
sNuq
Return successful
gNuq+xxxxxxxx+c
Return Error
gN@Ezzz+c
Parameters
N
Module ID
xxxxxxxx
Distance in 0.1mm
c
0 = no new measurement since last sNuq command
1 = one new measurement since last sNuq command, not overwritten
2 = more than one measurement since last sNuq command, overwritten
zzz
Error code
Distance Laser Sensor
Page 34/41
TECHNICAL REFERENCE MANUAL
8.7 Error codes
No.
Format
Meaning
203
@E203
Wrong syntax in command, prohibited parameter in command entry or non-valid result
210
@E210
Not in tracking mode, start tracking mode first
211
@E211
Sampling too fast, set the sampling time to a larger value
212
@E212
Command cannot be executed, because tracking mode is active, first use command sNc to stop tracking
mode
220
@E220
Communication error
230
@E230
Distance value overflow caused by wrong user configuration. Change user offset (and/or user gain)
231
@E231
Wrong mode for digital input status read
232
@E232
Digital output 1 cannot be set if configured as digital input
233
@E233
Number cannot be displayed. (Check output format)
234
@E234
Distance out of range
236
@E236
Digital output manual mode (DOM) cannot be activated when configured as digital input
252
@E252
Temperature too high
(contact Dimetix if error occurs at room temperature)
253
@E253
Temperature too low
(contact Dimetix if error occurs at room temperature)
254
@E254
Bad signal from target
It takes too long to measure according distance
255
@E255
Received signal too weak
(Use different target and distances, if the problem persists, please contact Dimetix)
256
@E256
Received signal too strong
(Use different target and distances, if the problem persists, please contact Dimetix)
257
@E257
Too much background light
(Use different target and distances, if the problem persists, please contact Dimetix)
258
@E258
Power supply voltage is too high
260
@E260
Distance cannot be calculated because of ambiguous targets. Use clearly defined targets to measure the
distance.
360
@E360
Configured measuring time is too short
361
@E361
Configured measuring time is too long
not listed
Hardware failure (Contact Dimetix)
Before contacting Dimetix, please collect as much information as possible.
Distance Laser Sensor
Page 35/41
TECHNICAL REFERENCE MANUAL
9 Safety instructions
The following instructions are to enable the person responsible for the DLS-C(H)/FLS-C(H), and the user of the instrument, to anticipate and
avoid operational hazards.
The DLS-C(H)/FLS-C(H) is made to be integrated into technical systems. Basic technical training is therefore essential. This device may only be
operated by trained personnel.
The person responsible for the instrument must ensure that all users understand these instructions and adhere to them.
If the DLS-C(H)/FLS-C(H) is part of a system, the manufacturer of such a system is responsible for all safety-related issues, such as the manual,
labeling and instruction.
9.1 Use of the instrument
Permitted use:
The permitted use of the DLS-C(H)/FLS-C(H) is: measuring distances.
Prohibited use:
1)
Use of the instrument without instruction
2)
Use outside the stated limits
3)
Deactivation of safety systems and removal of explanatory and hazard labels
4)
Opening of the equipment, except to open the cover for access to the screw terminal
5)
Carrying out modification or conversion of the product
6)
Operation after failure in operation
7)
Use of accessories from other manufacturers without the express approval of Dimetix
8)
Aiming directly into the sun
9)
Deliberate dazzling of third parties; also in the dark
10)
Inadequate safeguards at the surveying location (e.g. when measuring on roads, etc.)
WARNING:
Prohibited use can lead to injury, malfunction, and material damage. It is the duty of the person responsible for the
instrument to inform the user about hazards and how to counteract them. The DLS-C(H)/FLS-C(H) must not be
operated until the user has been adequately instructed.
9.2 Limits to use
) See 4 Technical data on page 14.
Environment:
Suitable for use in an atmosphere appropriate for permanent human habitation. The device must not be used in environments such as but
not limited to:
–
aggressive vapor or liquids
–
snow and rain
–
radiation (radioactive, heat, etc)
–
explosive atmosphere
Distance Laser Sensor
Page 36/41
TECHNICAL REFERENCE MANUAL
9.3 Areas of responsibility
Responsibilities of the manufacturer of the original equipment Dimetix AG, CH-9100 Herisau
(Dimetix):
Dimetix is responsible for supplying the product, including the Technical Reference Manual and original accessories, in a completely safe
condition.
Responsibilities of the manufacturer of non-Dimetix accessories:
The manufacturers of non-Dimetix accessories for the DLS-C(H)/FLS-C(H) are responsible for developing, implementing and communicating
safety concepts for their products. They are also responsible for the effectiveness of these safety concepts in combination with the Dimetix
equipment.
Responsibilities of the person in charge of the instrument:
WARNING:
The person responsible for the instrument must ensure that the equipment is used in accordance with the
instructions. This person is also accountable for the deployment of personnel and for their training and for the safety
of the equipment when in use.
The person in charge of the instrument has the following duties:
1)
To understand the safety instructions for the product and the instructions in the Technical Reference Manual.
2)
To be familiar with local safety regulations relating to accident prevention.
3)
To inform Dimetix immediately if the equipment becomes unsafe.
9.4 Hazards in use
WARNING:
The absence of instruction, or the inadequate provision of instruction, can lead to incorrect or prohibited use, and
can give rise to accidents with far-reaching personal, material and environmental consequences.
Precautions:
All users must follow the safety instructions given by the manufacturer and the directions of the person responsible for the instrument.
CAUTION:
Beware of erroneous distance measurements if the instrument is defective or if it has been dropped or has been
misused or modified.
Precautions:
Carry out periodic test measurements, particularly after the instrument has been subject to abnormal use, and before, during and after
important measurements. Make sure the DLS-C(H)/FLS-C(H) optics are kept clean.
WARNING:
If labels are hidden when the DLS-C(H)/FLS-C(H) is installed, this could lead to dangerous situations.
Precautions:
Always ensure the visibility of DLS-C(H)/FLS-C(H) labels at all times or add labels in accordance with the local safety regulations.
CAUTION:
When using the instrument for distance measurements or for positioning moving objects (e.g. cranes, building
equipment, platforms, etc.) unforeseen events (e.g. breaking the laser beam) may cause erroneous measurements.
Distance Laser Sensor
Page 37/41
TECHNICAL REFERENCE MANUAL
Precautions:
Only use this product as a measuring sensor, not as a control device. The system must be configured and operated in such a way that no
damage will occur the event of an erroneous measurement, malfunction of the device or power failure due to installed safety measures (e.g.
safety limit switch).
WARNING:
Operate the equipment appropriately in accordance with the regulations in force. Always prevent access to the
equipment by unauthorized personnel.
Precautions:
Do not point the telescope directly at the sun.
CAUTION:
Be careful when pointing a telescope towards the sun, because the telescope functions as a magnifying glass and
can injure eyes and/or cause damage inside the DLS-C(H)/FLS-C(H).
9.5 Laser classification
The DLS-C(H)/FLS-C(H) produces a visible laser beam, which emerges from the front of the instrument.
It is a Class 2 laser product in accordance with:
- IEC60825-1 (2007) ”Radiation safety of laser products”
- EN60825-1 (2007) ”Radiation safety of laser products”
It is a Class II laser product in accordance with:
- FDA 21CFR 1040.10 and 1040.11 (US Department of Health and Human Service, Code of Federal Regulations)
Laser Class 2/II products:
Do not stare into the laser beam or direct it towards other people unnecessarily. Eye protection is normally afforded by aversion responses
including the blink reflex.
WARNING:
Looking directly into the beam with optical aids (binoculars, telescopes) can be hazardous.
Precautions:
Do not look into the laser beam. Make sure the laser is aimed above or below eye level. (particularly with fixed installations, in machines,
etc.).
CAUTION:
Looking into the laser beam may be hazardous to the eyes.
Precautions:
Do not look into the laser beam. Make sure the laser is aimed above or below eye level. (particularly with fixed installations, in machines,
etc.).
Distance Laser Sensor
Page 38/41
TECHNICAL REFERENCE MANUAL
9.6 Electromagnetic compatibility (EMC)
The term ”electromagnetic compatibility” is taken to mean the capability of the DLS-C(H)/FLS-C(H) to function smoothly in an environment
where electromagnetic radiation and electrostatic discharges are present, and without causing electromagnetic interference to other
equipment.
WARNING:
Electromagnetic radiation can cause interference in other equipment. Although the DLS-C(H)/FLS-C(H) meets the
strict regulations and standards that are in force in this respect, Dimetix cannot completely exclude the possibility
that interference may be caused to other equipment.
9.7 Producer Standards
Dimetix hereby certifies that the product has been tested and complies with the specifications as stated in this 'Technical Reference Manual'.
The test equipment used is in compliance with national and international standards. This is established by our Quality Management System.
Further, the DLS-C(H)/FLS-C(H) devices are produced in compliance with 2002/95/EG «RoHS».
9.8 Disposal
This symbol on the product or on its packaging indicates that this product must not be disposed of with your
other household waste. Instead, it is your responsibility to dispose of the equipment by handing it over to a
designated collection point for the recycling of waste electrical and electronic equipment. The separate collection
and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure
that it is recycled in a manner that protects human health and the environment. For more information about
where you can drop off your waste equipment for recycling, please contact your local city office, your household
waste disposal service or the dealer where you purchased the product.
In countries in which Dimetix has no subsidiaries, Dimetix delegates the duty for the disposal in compliance with
2002/96/EG«WEEE» to the local dealer or to the customer, if no dealer is present.
Distance Laser Sensor
Page 39/41
TECHNICAL REFERENCE MANUAL
9.9 Labeling
9.10 Laser Specification
Standard applied
EN60825-1:2007
IEC60825-1:2007
Emitted wavelength
620-690nm
Beam divergence
0.16 x 0.6 mrad
Pulse duration
0.45x10-9s
Max. radiant power
0.95 mW
9.11 Maintenance
The DLS-C(H)/FLS-C(H) is almost maintenance free. The only thing you have to do is to clean the surfaces of the lenses.
CAUTION:
Look after the surfaces of the lenses with same care that you would apply to spectacles, cameras and field glasses.
Clean the optical parts only with a clean soft glasses cleaning cloth and avoid scratching of the optical parts.
9.12 Service
If you need to service the device, please contact Dimetix for instructions.
CAUTION:
The warranty is void if the device is opened except the cover of the screw terminal. Removing the label is also
understood as opening.
Distance Laser Sensor
Page 40/41
Fig. 8: Location of the label
Fig. 10: all existing type labels
FLS-C 30
Part No.:
600 501
Manufactured:
Serial No.:
123456
11/2009
Power: 9..30V / 0.6A=
Type:
FLS-C 10
Part No.:
600 502
Manufactured:
Serial No.:
123456
11/2009
Power:
9..30V / 0.6A=
Type:
FLS-CH 30
Part No.:
600 503
Manufactured:
Serial No.:
123456
11/2009
Power: 9..30V / 2.5A=
Type:
FLS-CH 10
Part No.:
600 504
Manufactured:
Serial No.:
123456
11/2009
Power: 9..30V / 2.5A=
Type:
DLS-C 30
Part No.:
500 621
Manufactured:
Serial No.:
123456
11/2009
Power: 9..30V / 0.6A=
Type:
DLS-C 15
Part No.:
500 622
Manufactured:
Serial No.:
123456
11/2009
Power: 9..30V / 0.6A=
Type:
DLS-CH 30
Part No.:
500 623
Manufactured:
Serial No.:
123456
11/2009
Power: 9..30V / 2.5A=
Type:
DLS-CH 15
Part No.:
500 624
Manufactured:
Serial No.:
123456
11/2009
Power:
9..30V / 2.5A=
Type:
Fig. 9: DLS-C / FLS-C label inclusive type label
1
9
15
8
Power
Error
DO 1
DO 2
1
Rx
2
Tx
3
T -
4
T+
5
R -
6
R+
7
V+
8
V+
9
DO 1
10
DO 2
11
DO E (Error)
12
AGND
13
AO
14
GND
15
GND
RS232
If2
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
Dimetix AG CH-9100 Herisau
WWW.DIMETIX.COM
Com plies with 21CFR 1040.10 and
1040.11 except for deviations pursuant
to Laser Notice no.50, dated May 2001,
with IEC 60825-1 (2001) and
EN 60825-1 (2001)
620-690nm
0.95m W m ax.
Class 2
Laser Product
Made in Switzerland
FLS-C 10
Part No.:
600 502
Manufactured:
Serial No.:
123456
11/2009
Power: 9..30V / 0.6A=
Type:
TECHNICAL REFERENCE MANUAL
Important Notice
Dimetix reserves the right to make corrections, modifications, enhancements, improvements and other changes to its products,
documentation and services at any time and to discontinue any product or service without notice. We try to give our best possible effort to
provide you with perfect documents, but we can not guarantee for incorrect information. Customers should obtain the latest relevant
information before placing orders and should verify that such information is up to date and complete. All products are sold subject to Dimetix
terms and conditions of sale supplied at the time of order acknowledgment.
© Copyright by Dimetix
Dimetix AG
Degersheimerstr. 14
CH-9100 Herisau
Switzerland
Tel. + 41–71–353 00 00
Fax + 41–71–353 00 01
[email protected]
www.dimetix.com