Blasi C 127 SU S Operating Instructions Manual
Read Online
Read the Blasi C 127 SU S Operating Instructions Manual online using the built-in PDF viewer.
C 127 SU S Operating Instructions Manual: Key Pages of Document
04/2013 Rev. B Article no.: 121-127401297 Automatic Under-floor Swing Door Operator C 127 SU S Operating instructions E Page 1. General 2 2. Safety instructions 3 3. Technical data 4 4. Construction and function 5 - 6 5. Dimensions 7 6. Operating instructions 8 - 10 7. Configurations 11 - 12 8. Maintenance instructions 13 9. Action in case of faults 14 - 18 10. Taking out of service and disposal 19 11. Appendix 20 Blasi GmbH Carl-Benz-Str. 5-15 DE-77972 Mahlberg Phone +49 7822 893-0 Fax +49 7822 893-119 ...
04/2013 Rev. B Operating instructions C 127 SU S 1 General These operating instructions are intended for the C 127 SU S automatic under-floor swing door op- erator (herein after referred to as C 127). The operator is the person responsible for the technical maintenance of this door system. These instructions describe the use of the C 127 swing door operator. They form the basis for satis- factory functioning. These operating instructions should be read by the door operator before commissioning and the safety instructions observed! It is recommended to keep these operating instructions close to the automatic sliding door. Product designati ...
04/2013 Rev. B Page 3 of 20 2 Safety instructions The operator has been constructed in accordance with the latest state of the art and the recognised technical safety regulations, including limiting of forces and speeds. Nevertheless, danger can arise for the user if not used as intended. Installation, maintenance and repairs to the operator must only be performed by quali- fied and authorized personnel (technicians). 2.1 Use as intended The C 127 swing door operator is constructed exclusively for normal service with swing doors in dry rooms and must be installed within or inside buildings. The stainless steel casing ...
04/2013 Rev. B Operating instructions C 127 SU S 3 Technical Data Dimensions: 710 x 200 x 130 mm (stainless steel casing LxBxT) Operating voltage: 230VAC, 50/60 Hz Power consumption: Standby 13 W, rated power 67 W Max. torque: 50 Nm Mass moment of inertia: 65 kgm2 (C 127 SU S) Opening angle: Adjustable from 70° to 115° Time delay: Adjustable from 0 to 60 seconds (40 steps) Opening speed: Adjustable from 3 to 20 seconds (40 steps) Closing speed: Adjustable from 5 to 20 seconds (40 steps) Noise emission: < 45 dB Protection class: IP 67 Environment conditions Temperature range: -15° to +50° C Humidity range: Up to 85% relative humidity, ...
04/2013 Rev. B Page 5 of 20 4 Construction and Function 4.1 Construction Key to illustration: 1 Standard arm 11 Closing spring 2 Floor plate 12 Multifunctional switch MF on STG 3 Cover with flat seal 13 STG control unit 4 Drive C 127 incl. control unit 14 STG connection terminals 5 Stainless steel casing 15 Motor print MOT 6 Box out for floor installation 16 Slide switch S1 (rotation direction) 7 Adjusting screw for spring tension 17 ATE drive unit terminals 8 Vision panel, adjust. spring tension 18 Mains connection terminals 9 Connectors for arms (both sides) 19 Fine-wire fuse 10 ATM drive unit 20 NET power supply 1 ...
04/2013 Rev. B Operating instructions C 127 SU S Construction and Function 4.2 Components The C 127 swing door operator forms part of an electromechanical swing door system and com- prises the following main components: Control unit STG: Intelligent, learning, microprocessor-controlled control system. Driving unit ATE: Low maintenance DC geared motor with electronic path measure- ment and integral thermostatic protective switch, gear box with ad- justable spring tension. Power supply NET: Compact 230 V power supply with integral input filter and over- voltage protection. Control unit BDE: As required with convenient, simple mechanical co ...
04/2013 Rev. B Page 7 of 20 5 Dimensions 5.1 Installation with box out 5.2 Operator in stainless steel casing Standard arm ...
04/2013 Rev. B Operating instructions C 127 SU S 6 Operating instructions 6.1 Controls on the STG 127 General The STG 127 operates with an active HIGH level, i.e. a +24 V level must be applied to activate a function. Safety inputs are activated during interruptions. The signal ground (0V) is connected to the protective earth. Jumpers J13: CAN line termination J14: Master / Slave jumper at position M1 for master (factory setting) jumper at position S1 for slave LED’s LD1: (red) Control LED for push-button operation (S1) LD2: (green) +35V Off for power failure LD3: (green) +24V Lights up if +24V present. Caution: in the event of a power f ...
04/2013 Rev. B Page 9 of 20 T Operating instructions 6.2 Functions of electronic controller BDE-D (optional) The BDE-D electronic controller is an easily operated input and output device for the control and adjustment of door operators. Logically arranged pushbuttons allow intuitive operation and navigation through the operator-specific menu. The LCD with backlight shows data and information about the door status with symbols and text messages. Additional information can be found in the BDE-D manual. 6.3 Operation modes Table of signals (X marks a release reaction) Automatic / AUTO Normal function. The door opens ...
04/2013 Rev. B Operating instructions C 127 SU S Operating instructions Manual operation / HAND The door can be opened and closed by hand. The actuating devices connected are ignored. Continuously open / OPEN The door is opened and stays open. If an obstruction stands in the way while opening, the operator tries another five times within a few seconds to bring the door to the target open position. Should the obstruction remain, the current position is then validated as the continuously open position. Locked The locking is activated in the Locked operation mode. CLOSED OPENING OPEN CLOSING AKI x x x AKA x x x SSK x x x x SIO x ...
04/2013 Rev. B Page 11 of 20 7 Configurations 7.1 Parameter Overview Factory settings: Basic operator (Full Power) ...
04/2013 Rev. B Operating instructions C 127 SU S Configurations Configurations of the C 127 can only be made with the electronic BDE-D. Further information for parameter changes can be taken from the user manual of the BDE-D (no. 102-903109271). Please always leave the configuration review sheet in the drive! 7.2 Parameter description Parameter Setting range Factory de- fault Description DRIVING CYCLE Closing speed 0 - 40 (5 - 20 s) 18 Slider control with 40 steps Opening speed 0 - 40 (3 - 20 s) 36 Slider control with 40 steps DIN: > 1.5 s < 4 s TIME DELAY OPEN Time delay open 0 - 40 (0 - 60 s) 2 Effective with AKA, AKI and push to act ...
04/2013 Rev. B Page 13 of 20 8 Maintenance instructions 8.1 General The C 127 swing door operator is a product of the latest technology. It has been carefully made and only leaves the factory following thorough testing. Automatic swing doors should be operated and maintained to ensure safety at all times. 8.2 Care The entire swing door system can be cleaned with a damp cloth and commercially available cleaning agents. The cleaning agent must be harmonised to the surface which has to be cleaned. It is recommended to select the "Continuously open" or "Locked" mode of operation for this purpose, so that the door does not ...
04/2013 Rev. B Operating instructions C 127 SU S 9 Action in case of faults 9.1 Fault indication Various indications are given for an irregularity or fault depending on the control unit connected BDE-E or BDE-M. When using an electronic BDE-D Information about the operator system, like e.g. the software version, can be read out of the BDE-D main display by pressing the key. Telephone number, fault and maintenance are only displayed, when this function has been activated by the service technician. After pressing this key once again, the phone number of the responsible service centre and the last appeared fault indication is displayed in ...
04/2013 Rev. B Page 15 of 20 Action in case of faults 9.2 Error display and troubleshooting Various indications are given for an irregularity or fault depending on the control unit connected BDE- E or BDE-M. In case of an anomaly in the operator system, the standard screen of the BDE-D auto- matically shifts from operating mode to error display. After 2 seconds, display changes between normal / inverse. If several errors are active, they are numbered: For instance, error 1/2 means that the first one of 2 errors is displayed. Browsing through error displays: Temporary return to main display for 4 seconds after browsin ...
04/2013 Rev. B Operating instructions C 127 SU S Action in case of faults No. Display text Reset Comments and possible troubleshooting 3 AKI > 60s active Inside radar longer than 60 sec. active and door re- mains open. Check that no moving objects are activating the radar. Door can be locked with 5 AKA > 60s active Outside radar longer than 60 sec. active and door re- mains open. Check that no moving objects are activating the radar. Door can be locked with 6 Unlocking error X Unlocking error: it is impossible to unlock the door. Repeat unlocking attempt after changing the BDE op- erating mode. If door cannot unlock, check locking devic ...
04/2013 Rev. B Page 17 of 20 Action in case of faults No. Display text Reset Comments and possible troubleshooting 52 No running parameter X Door must be calibrated (perform teach-in run). 53 Interruption motor X Motor is not plugged in. Motor is faulty. Afterwards reset. 54 W Calibration run X Warning message: Calibration run is performed. 59 SIS > 60s active X Door does not close. Light barriers disconnected and door remains open. Check that safety barriers are not covered or extremely dirty. Check that the cabling to the sensor is not inter- rupted, the learning time is longer than 60 s or the filter is covered or ...
04/2013 Rev. B Operating instructions C 127 SU S Action in case of faults No. Display text Reset Comments and possible troubleshooting 97W Maintenance ex- ceeded X Warning message: Actual value = 105% of target value of cycles or operat- ing hours. Acknowledge message. Alarm is reset for 13 days. Inform after-sales service and have installation ser- viced. 98W Maintenance is due X Warning message: Actual value = 95% of target value of cycles or operat- ing hours. Repeat at 100%. Acknowledge message. Alarm is reset for a short time. Inform after-sales service and have installation ser- viced. 99W Operator rotates X Rotate + lubricate fun ...
04/2013 Rev. B Page 19 of 20 10 Taking out of service and disposal 10.1 Taking out of service When the swing door operator C 127 is discontinued or taken out of service, it is disconnected from the power supply. After every temporary discontinuation, a new commissioning has to be carried out. 10.2 Dismantling and disposal ATTENTION All the parts of the machine must be sorted by material types and disposed of according to local regulations and guidelines. The swing door operator C 127 installation can consist of the following materials among other things: Aluminium: • Chassis profile, profiles of the arm system • G ...
04/2013 Rev. B Operating instructions C 127 SU S 11 Appendix 11.1 Standard arm SG 11.2 Sliding arm GG ...