Aqua Science Fleck 5600 Easy Programming Manual
Text of the manual
Fleck 5600 & 2510 12 Day Timer Easy Programming Guide
Setting Time of Day:
Press red button and rotate largest spin wheel (with serrated edges) until the current time is displayed
in the “time of day” window.
Fleck 5600 & 2510 12 Day Timer Easy Programming Guide
Setting Backwash Frequency:
The 12 day timer comes with all 12 pins pushed inward.
To indicate the days you want to backwash, simply push that particular pin outward from the center.
The industry standard is for every 3 days. That will result in the 1,4,7 and 10 pins bei
Fleck 5600 & 2510 12 Day Timer Easy Programming Guide
Final Steps:
Once your control valve is set to run, clip the stainless steel bypass to the inlet/outlet.
Next, turn the central dial clockwise into backwash and slightly turn the bypass valve into service. After
a few minutes you can fully open the bypass valve into serv