Danfoss VLT HVAC Programming Manual
Text of the manual
1.1.1 Copyright, Limitation of Liability and Revision Rights
5
1.1.2 Symbols
6
1.1.3 Abbreviations
6
1.1.5 Definitions
7
1.1.6 Electrical Overview
11
2 How to Programme
12
2.1 Programming with MCT-10 Setup software
12
2.2 Local Control Panel (LCP)
12
2.3 Menus
13
2.3.1 Status
13
2.3.2 Quick Menu
13
2.3.3 The FC101 Start-up Wizard
3.4.1 3-0* Reference Limits
30
3.4.2 3-1* References
30
3.4.3 3-4* Ramp 1
31
3.4.4 3-5* Ramp 2
31
3.4.5 3-8* Other Ramps
32
3.5 Main Menu - Limits/Warnings - Group 4
33
3.5.1 4-1* Motor Limits
33
3.5.2 4-5* Adj. Warnings
33
3.5.3 4-6* Speed Bypass
34
3.6 Main Menu - Digital In/Out - Group 5
35
3.6.1 5-0* Digital I/O Mode
35
3.6.2 5-1* Digital Inputs
35
3.6.3
3.11 Main Menu - Drive Information - Group 15
61
3.11.1 15-0* Operating Data
61
3.11.2 15-3* Alarm Log
61
3.11.3 15-4* Drive Identification
61
3.12 Main Menu - Data Readouts - Group 16
63
3.12.1 16-0* General Status
63
3.12.2 16-1* Motor Status
63
3.12.3 16-3* Drive Status
64
3.12.4 16-5* Ref. & Feedb.
64
3.12.5 16-6* Inputs and Outputs
65
3.12.6 16-8* Fiel
5.1.9 8-** Comm. and Options
86
5.1.10 13-** Smart Logic
87
5.1.11 14-** Special Functions
87
5.1.12 15-** Drive Information
88
5.1.13 16-** Data Readouts
89
5.1.14 18-** Info & Readouts
90
5.1.15 20-** Drive Closed Loop
90
5.1.16 22-** Appl. Functions
90
5.1.17 24-** Appl. Functions 2
91
Index
92
Contents
VLT HVAC Basic Drive Programming Guide
4
MG.18.B1.02
VLT HVAC Basic Drive
Software version: 1.2X
This guide can be used with all VLT
HVAC Basic Drive frequency
converters with software version
1.2X.
The actual software version number
can be read from
15-43 Software Version.
1.1.1 Copyright, Limitation of Liability and
Revision Rights
This publication contains information proprietary to Danfoss.
Symbols used in this guide.
NOTE
Indicates something to be noted by the reader.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury or
equipment damage.
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
*
Indicates def
1.1.4 Available Literature for VLT HVAC Basic
Drive
-
Quick Guide MG.18.Ax.yy
-
Programming Guide MG.18.Bx.yy provides
information on how to programme and includes
complete parameter descriptions.
-
Design Guide MG.18.Cx.yy entails all technical
information about the frequency converter and
customer design and applications.
-
PC-based Configuration Tool MCT-