Comet T3319 Instruction Manual

File Specifications

Brand: Comet
Category: Transmitter
Model: T3319 (Instruction Manual), prds8GscRc/po
File Type: PDF
File Size: —
Pages: 16 pages

Download PDF

Download Comet T3319 Manual (16 pages)

Read Online:

Read the Comet T3319 Instruction Manual online using the built-in PDF viewer.

Key Pages of Document

Programmable transmitter of temperature, relative

humidity and other derived humidity values T3319, T3319P, T3419, T3419P Programmable transmitter of atmospheric pressure, temperature, relative humidity and other derived humidity values T7311, T7411 with RS232 / RS485 serial output and external probe Instruction Manual ...

Temperature Humidity Pressure Computed

values Output Version T3319 ✓ ✓ - ✓ RS232 probe with cable T3319P ✓ ✓ - ✓ RS232 probe for compressed air *) T3419 ✓ ✓ - ✓ RS485 probe with cable T3419P ✓ ✓ - ✓ RS485 probe for compressed air *) T7311 ✓ ✓ ✓ ✓ RS232 probe with cab ...

9600Bd, without parity, 2 stop bits

display: switched ON value displayed at higher line: temperature (temperature / pressure) – by device type value displayed at lower line: relative humidity only temperature unit: °C pressure unit: hPa preset computed ...

Dimensions – T3319(P), T7311

transmitter with RS232 serial output probe for compressed air measurement Typical application wiring of T3319(P) and T7311 power from communication port power from external voltage source ...

Dimensions – T3419(P), T7411

transmitter with RS485 serial output probe for compressed air measurement Typical application wiring of T3419(P), T7411, connection of terminals ...

Dimensions – T3319L, T3419L, T7311L, T7411L

Connection: see Appendix B Info mode If in doubt of setting of installed device, verification of its address is enabled even without using computer. Power should be connected. Devices with RS232 interface have address always set to one. Unscrew device cover and shortly press button n ...

Setting of pressure correction for altitude

For devices T7311 and T7411 only! If there is necessary to read value of atmospheric pressure corrected with respect to altitude, it is possible to set corresponding pressure offset for this altitude. It is possible to do it with Users software. This value is then automatically added t ...

Modbus registers of the device

Variable Unit Address [hex]X Address [dec]X Format Size Status Measured temperature [°C] [°F]* 0x0031 49 Int*10 BIN16 R Measured relative humidity [%] 0x0032 50 Int*10 BIN16 R Computed value * [*] 0x0033 51 Int*10 BIN16 R Address of device [-] 0x2001 8193 Int BIN16 R/W* Code of communication spee ...

should respond. During communication data is transferred in ASCII format (in characters). Each

Byte is sent as two ASCII characters. Device supports communication speed from 1200Bd to 115200Bd, parameters of communication link are 1 start bit + eight bit data word (LSB first) + 1 stop bit, without parity. Jumper Jumper is locate ...

pressure at kPa (depended by device type). For atmospheric pressure correction to altitude setting

there is Users software Tsensor. Jumper and button If communication with HWg Poseidon unit is selected, the function of jumper and button is as follows: • Jumper opened and button shortly pressed – device goes to Info mode, se ...