Aventics C-2 Service Information
Text of Aventics C-2 Service Information
The C-2 Relay Valve functions to reproduce in
substantial volume whatever pressure is applied to the
small volume control portion of the valve itself. Its
essential purpose is to increase the speed of operation
for devices such as brakes, clutches, positioning
devices and to reduce trans-mission time in control
lines. This valve is usually direct
Fig. 2 Outline View
4 17/32”
3 25/32”
7 ¼”
REPAIR PARTS LIST
Old Part Number
New Part
Number
Ref.
No.
-538975-00000
-850012-00000
R431000091
R431000110
C-2 RELAY VALVE, complete
RELAY VALVE PORTION complete
(Includes Ref. Nos. 2 to 42, inclusive)
P –050756-00001
-850050-00000
R431002759
R431000127
2
BODY, Relay Valve
VALVE, Supply complete (Includes
3,5,9,10 and R431000128)
-85
Referring to Figure 4, with supply air
pressure present in port 1 and no air pressure
present on the control diaphragm 36, both the
supply valve 7 and the exhaust valve 24 will be
seated by their respective springs. Assume that
air pressure is admitted to the control port 2 of
the valve. This pressure will be delivered to the
upper side of diaphragm
NOTICE TO PRODUCT USERS
1. WARNING: FLUID MEDIA
AVENTICS pneumatic devices are designed and tested for use
with filtered, clean, dry, chemical free air at pressures and
temperatures within the specified limits of the device. For use
with media other than air or for human life support systems,
AVENTICS must be consulted. Hydraulic cylinders are designe