Bosch DS304 Installation Instructions Manual

Specifications

Brand: Bosch
Category: Security System
Model: DS304 (Installation Instructions Manual)
File Type: PDF
File Size: —
Pages: 8

Read Online

Read the Bosch DS304 Installation Instructions Manual online using the built-in PDF viewer.

Text of the manual

Bosch Security Systems | 1/05 | 4998122424F

EN | 2 1.0 Installation Considerations 1.0 Installation Considerations • Not suitable for outdoor use. • Point away from direct and indirect sunlight. • Point away from glass or other objects that rapidly change temperature. • Do not install this detector where pets are present. • Select a mounting location where an intruder is most likely to cross the coverage pattern perpendicular to the detection zones. • Mount the detector 6.6 ft to 8.5 ft (2 m to 2.6 m) above the floor. 2.0 Installation Refer to Figures 1 and 2 when preparing the detector. Ensure the mounting surface is solid and free of vibration. 1. Remove the cover by inserting a thin, flat-blade screwdriver into the notch at the bottom of the cover and prying up. 2. Remove the circuit board by pressing one of the circuit board retainer tabs toward the side of the enclosure and lifting the circuit board up and out of the enclosure base. 3. Remove the mirror by sliding it out of its tracks. 4. Remove an appropriate wiring knockout. 5. To surface or corner mount, go to Section 2.1 Surface or Corner Mounting. To bracket mount, go to Section 2.2 Bracket Mounting on page 3. 2.1 Surface or Corner Mounting 1. Remove the knockout holes for either surface or corner mounting. 2. Using the enclosure as a template, mark the location for the mounting screws. Use wall anchors as needed. 3. Mount the detector. 4. Insert the wiring. 5. For strain relief, attach the cable to the cable tie with the plastic tie-down (supplied). 6. Replace the mirror and circuit board. Figure 1: Rear Enclosure 7 3 1 5 5 6 2 3 6 4 1 - Wiring knockouts (3) 2 - Cable tie/strain relief 3 - Corner mounting holes (2) 4- Surface mounting holes (4) 5 - Circuit board retainer tabs (2) 6 - Mirror tracks (2) 7 - Bracket mounting hole Figure 2: Circuit Board 1 - Securing screw 4 - LED 2 - Terminal strip (2) 5 - Configuration switches 3 - Tamper switch 6 - Program jumper 1 2 3 OP N 2 6 5 1 2 3 4 DS304| Installation Instructions |

EN | 3

DS304| Installation Instructions | Bosch Security Systems | 1/05 | 4998122424F 3.0 Mirror Adjustment 2.2 Bracket Mounting 1. Attach the bracket to the mounting surface using the instructions supplied with the bracket. 2. Knock out the bracket mounting hole in the enclosure base and attach the enclosure to the bracket using the instructions supplied with the bracket. 3. Insert the wiring. 4. For strain relief, attach the cable to the cable tie with the plastic tie-down (supplied). 5. Replace the mirror and circuit board. 3.0 Mirror Adjustment 1. Determine the appropriate angle for the installation using the chart in Figure 3. Touching the mirror surface can reduce performance. 2. Use the angle adjustment markings shown in Figure 4 to set the maximum detection range needed. 3. Slide the mirror forward or back until the angle adjustment markings align with the markers on each side of the frame. Use the chart in Figure 3 located inside the front cover to set the correct angle. 4. Adjust the horizontal protection coverage during the Walk Test. Refer to Section 7.0 Setup and Walk Testing on page 5. 4.0 Wiring Apply power only after all connections are made and inspected. Do not coil excess wire inside the enclosure. Seal the wire entrance with the plug provided. Figure 3: Mirror Angle Adjustment X Y 2.0 (6.5) 2.3 (7.5) 2.6 (8.5) Broad 20 (6) 35 (10) Curtain 40 (12) 70 (20) -10° - 6° - 4° - 2° -12° - 8° - 4° - 2° -14° - 10° - 6° - 4° Y m (ft) X m (ft) X = maximum range Y = mounting height Figure 5: Terminal Strip Connections 4 5 6 7 8 9 10 11 1 2 3 1 (SH) Shield (optional): Connection for ground wire from shielded cable. 2 (S/U*) Set/Unset (optional): Use as an alarm memory control input for remote panel arming or disarming. Also used as an electronic alarm output. Only one detector should be connected for each detector group. 3 (WT*) Walk Test (optional): Use for Walk Test remote control through the control panel. Allows a command at the control panel to enable or disable the Alarm LED. 4 & 5 (T) Tamper: Tamper contact is normally closed (open when cover opens). Rated 125 mA at 28 V. 6 & 9 (SP) Spare 7 & 8 (AL) Alarm: Solid-state Form “A” relay contacts normally closed (open on alarm). Rated 100 mA at 30 V. Do not use with capacitive or inductive loads. 10 (-) & Input power: Use no smaller than 11(+) 22 AWG (0.8 mm) wire. * Use a control panel or switch to 0 VDC with the S/U and WT option control inputs. Open control inputs are HIGH level (internal pull-up). Switch the input to achieve the LOW level (from <1.5 V up to a 2 kΩ resistance maximum). The active level is user-configurable. Figure 4: Adjustment Selections Mirror with expanded view showing the angle adjustment markings. -16 -8 0 +

Bosch Security Systems | 1/05 | 4998122424F

EN | 4 5.0 Configuration 5.1 Program Jumper for the S/U Control Terminal Use the S/U control terminal as an alarm memory control input by setting the jumper in the upper position as shown in Item 1 of Figure 6. Use the S/U control terminal as an electronic alarm output (open collector) by setting the jumper in the lower position as shown in Item 2 of Figure 6. 5.2 User DIP Switches 5.3 Adjusting Sensitivity Table 1: Sensitivity Settings DIP Switch 2 OFF Standard Sensitivity (Default): Recommended for maximum false alarm prevention. Tolerates environmental extremes. Not recommended for curtain patterns. DIP Switch 2 ON Intermediate Sensitivity: Recommended for any location where an intruder is expected to cover only a small portion of the protected area, or when you want improved catch performance. Does not tolerate normal environments. 5.4 LED Setup Without S/U and WT Remote Control Panel Inputs Table 2: LED Setup Without Control Panel Inputs DIP Switch Settings LED Operation User DIP Switch 1 Walk Test User DIP Switch 3 Set/Unset Disable LED Any ON Enable LED OFF (default) OFF (default) 5.0 Configuration Figure 7: User DIP Switches 3 1 2 1 2 3 OPEN 1 - Walk Test polarity (Refer to Section 5.4 LED Setup Without S/U and WT Remote Control Panel Inputs.) 2 - Sensitivity (Refer to Section 5.5 Setup for Remote Control Alarm Memory and LED Operation Using S/U and WT Inputs.) 3 - Set/Unset polarity (Refer to Section 5.4.) 1 - Alarm memory control input 2 - Electronic alarm output Figure 6: Program Jumper Settings 2 1 S/U AL S/U AL DS304| Installation Instructions |

EN | 5

DS304| Installation Instructions | Bosch Security Systems | 1/05 | 4998122424F 5.5 Setup for Remote Control Panel Alarm Memory and LED Operation Using S/U and WT Inputs Table 3: User DIP Switch Selection DIP Switch Function ON OFF 1 Select Walk Test polarity Low (0 V) = Walk Test active High (12 V) = Walk Test active (default) 3 Select Set/Unset polarity Low (0 V) = Unset High (12 V) = Set High (12 V) = Unset (default) Low (0 V) = Set (default) Ensure the control terminal program jumper is configured as shown in Item 1 of Figure 5 on page 3 (refer to Section 5.1 Program Jumper for the S/U Control Terminal on page 4). 6.0 Remote Control Operation Table 4: Remote Control Operation Control Line Status Arming Terminal Status Walk Test Terminal Status Detector Status LED Status Set OFF or ON Memory ready OFF Stored alarm Rapid flashing (2 Hz) OFF No stored alarm OFF Power up Slow flashing (0.5 Hz) Alarm activity ON for 4 sec Unset ON No alarms OFF Transition from Unset to Set OFF or ON Memory cleared OFF 6.0 Remote Control Operation 7.0 Setup and Walk Testing Enable the LEDs before performing a Walk Test. 1. Replace the cover and insert the cover tamper screw (if desired). 2. Apply power to the unit. 3. Wait at least 2 min for the detector to stabilize and no motion is detected (Figure 8). 4. Watch the LED as you walk to the farthest edge of the coverage pattern. Walk closer to the detector by crossing the pattern. The LED lights when it detects you crossing the coverage pattern. 5. Repeat from the other side. If the desired range is not achieved, try angling the mirror up or down to assure the coverage pattern is not aimed too high or too low. 8.0 Maintenance At least once a year, check the range and coverage according to Section 7.0 Setup and Walk Testing. To ensure continuous operation, instruct the end user to walk through the outer edge of the coverage area daily and observe the LED operation (if used). This also assures an alarm output prior to arming. Figure 8: Walk Testing Walk test across the pattern.

Bosch Security Systems | 1/05 | 4998122424F

EN | 6 9.0 Coverage Patterns 9.0 Coverage Patterns DS304| Installation Instructions | Figure 10: Curtain Mirror Coverage (optional OMLR93) 1 - Top view 2 - Side view, mirror adjusted to -2° 3 - Front polished surface view, mirror segment for pattern reference 0 m A C D E B +2 0 -8 -16 +2 0 -8 -16 3 2 0 m 0 m 2 m 21 m B D C E A 1 0 m 1.9 m 1.9 m 21 m 1 - Top view 2 - Side view, mirror adjusted to -6° 3 - Front polished surface view, mirror segment for pattern reference Figure 9: Wide Angle Coverage A B C D E F G H I J K L M N +2 0 -8 -16 +2 0 -8 -16 Q P O 3 E G F I H C D A B N M L K J P Q O 1 0 m 5.35 m 0 m 5.35 m 11 m 2 0 m 2 m 11 m 0 m

EN | 7

DS304| Installation Instructions | Bosch Security Systems | 1/05 | 4998122424F 10.0 Specifications Table 5: Specifications Input Power Use only an approved limited power source. Standby Power No internal standby battery. Standby power must be provided by an approved limited power source. For each hour of standby time needed, 22 mAh is required. Supply Voltage Range: 8 VDC to 16 VDC Nominal: 12 VDC nominal Maximum Ripple (0 to 120 Hz): 2 Vpp Voltage Monitoring: Alarm at less than 4 V Current Consumption (at 12 V) Quiescent: 5.5 mA Maximum at standby (LED on): 8.5 mA Alarm Output Relay Contact (Solid-State Relay): Opens in alarm; 30 V, 100 mA; R, <20 Ω Alarm Holding Time: 4 sec Alarm Relay Connect to a safety extra-low voltage (SELV) circuit only. Optional Electronic Alarm Output (alternate use of S/U Terminals) Inactive: Open collector output Active: Switch low through 1 kΩ Tamper Contact 28 V, 125 mA Connect to a SELV circuit only. Connect the tamper circuit to a 24-hour protection circuit. Control Inputs (Walk Test, S/U) LOW: 1.5 V or less HIGH: 3.5 V or more Coverage Wide Angle Mirror: 11 m x 11 m Curtain Mirror: 21 m x 3 m Walking Speeds Wide Angle Mirror: 0.2 m/s to 3.0 m/s Curtain Mirror: 0.2 m/s to 4.0 m/s Sensitivity Standard or intermediate Ambient Conditions Storage Temperature: -20°C to +60°C Operating Temperature: -10°C to +55°C Air Humidity (EN60721): <95% rH, non-condensing Housing Protection (EN60529, EN50102): IP41/IK02 Options B338 Ceiling Mount Bracket* OMLR93-3 Curtain Mirror * Misaligning these brackets can reduce the detector’s range and increase the dead zone area. 10.0 Specifications

Bosch Security Systems

130 Perinton Parkway Fairport, NY 14450-9199 USA www.boschsecurity.us Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 © 2004 Bosch Security Systems 4998122424F