Introduction
The CM744B 3G radio module allows you to interface
compatible security control panels to the GSM/GPRS /SMS
network providing a high reliability primary or backup
reporting path.
The unit is designed to plug onto the main control panel
with the supplied antenna mounting onto the metal
cabinet.
Module Compatibility
Panels Supported
Version
Solution 6000 Series
2.23
Getting Started
There are four main steps required to configure the
CM744B for reporting to the control room. The instruc
tions assume that you already have purchased a SIM card
and that the card has been charged with credit and acti
vated on the network if necessary.
1. Install the CM744B hardware on the control panel.
2. Install the antenna.
3. Configure the module’s features and parameters.
4. Configure the control panel for reporting.
Step 1 - Installing the Radio Module
Ensure that the panel is powered off before proceeding.
Plug the 3 short plastic standoffs into the module and
then plug it onto the Expansion Port header pins on the
panel as shown in. If you are connecting the CM744B to a
panel which also has a CM101B Voice Module fitted then
you should use the longer standoffs from the HW750 Riser
Kit.
Install the SIM card into the SIM 1 card position.
Step 2 - Installing the Antenna
Remove the knockout in the top of the cabinet and pass
the antenna lead through the hole ensuring the antenna
is on the outside of the cabinet. Screw the lead to the
socket on the radio module before power the panel.
Do not fix the antenna in place at this stage.
Step 3 - Configuring The Module
Once powered the radio will attempt to connect to the
network. This may take up to a minute to complete. Dur
ing this time the online indicator on the module will be on
solid. Once the radio has registered the online indicator
will begin to flash and the signal strength indicators will
show the current signal condition.
Experiment with the position of the antenna to find the
best signal strength before fixing it in place.
Step 4 - Configuring The Panel Reporting
Reporting configuration will vary depending on the re
quired options and whether or not the GSM module is to
be used as the primary or secondary reporting route.
Configure the required reporting formats in MENU 5-4-0
and 5-4-1. The system can be configured to report to the
base in CID and also to selected phone numbers via SMS,
or to the base in CID via PSTN line and then CID via GSM if
the PSTN line is cut.
All reporting scenarios are configured by varying the pro
gramming of the reporting format and reporting routes
configurations options.
Module Indicators
The module includes 7 led indicators which are used to
show status and signal strength. See table below.
Module Indicators
Indicator
Meaning
TX
Module Transmitting Data
RX
Module Receiving Data
Online
ON Steady = Not Registered On Network
Pulsing = Registered On Network
Signal 1
Signal strength indicators show relative
signal level at the radio. Signal indicator 1
on indicates weak signal and all 4 indicators
on indicates stronger signal strength.
Signal 2
Signal 3
Signal 4
Installer Reference Guide
3
Bosch Security Systems 07/15 CM744BIRG FTR1.1
Supported Reporting Formats
Version 2.22 of the Solution 6000 panel firmware is
required to support the CM744B.
The following reporting formats are currently supported
by the module.
SMS Format via GSM
CSV-IP Format via GPRS
Conettix Format via GPRS
Support for the MyAlarm iFob App and RAS upload /
download via GPRS is not currently supported but will be
available in a future panel firmware update.
There is no support in the 3G module for Contact ID (CID)
over GSM.
CLI Trigger Output Control
The CLI trigger tables in MENU 6-5-5-1 and 6-5-6-2 can be
used to store a list of telephone numbers that can trigger
an output on the control panel. If you call the GSM unit
from a telephone number that matches a number in the
CLI list then the appropriate output will be operated.
An output needs to be programmed with an event type of
CLI Trigger and event assignment of 1 or 2 depending on
which table is to be checked.
Simply call the GSM unit from a telephone number that is
programmed in the CLI trigger list to activate the output.
Module Status
MENU 6-5-0 can be used to obtain various information on
the radio module. The following information is currently
available.
1) Connected Network
2) Signal Strength in dB
3) IMEI Number
4) Radio Firmware Revision
5) SIM Card Present
Dial Number Test
It is possible to check the SIM phone number by selecting
the dial number test via GSM option in MENU 5-9-5.
SMS Remote Control
The SMS control option in MENU 6-5-6 allows you to
program up to 10 telephone numbers that are allowed
to send SMS commands to the GSM unit. The first num
ber in this list is considered as the administrator who will
also receive SMS messages that the GSM unit is unable to
interpret. i.e. any message sent to the radio which cannot
be interpreted will be sent back via SMS to the first num
ber in the SMS control number list.
Numerous commands can be sent to the panel using the
SMS control functions including arming/ disarming areas,
controlling outputs and doors or checking system status.
The panel can also be requested to send a confirmation
SMS if required.
The control messages must be sent to the SIM phone
number.
The SMS Control phrase table shows the correct method
for constructing the SMS messages. Note there are no
spaces between the fields only commas as shown.
SMS Control Smartphone App
The MyAlarm SMS Control App for iOS and Android
devices is now available and can be used to simplify the
configuration and sending of SMS control messages.
You can search for the MyAlarm SMS Control app in the
app store or scan the QR codes below using your device’s
barcode reader for a direct link to the app.
Scan Here (iOS Version)
Installer Reference Guide
4
Bosch Security Systems 07/15 CM744BIRG FTR1.1
Scan Here (Android Version)
SIM Balance Recharge Reminder Function
In Solution 6000 version 2.20 firmware, a new SIM ex
pire parameter can be added to the to the SIMBAL setup
command when using the GSM module with a pre-paid
SIM card. When configured the control panel will send a
reminder to the designated SIM owner prompting them
to recharge the SIM before it expires.
The SIM Balance string would include the follows param
eters including the new optional reminder in weeks (01 to
52 weeks).
The MyAlarm SMS Control smart device app has been
updated to include support for this new feature. For more
information refer to the example below.
User Code
This field is used to enter your PIN (eg. 2580).
Command Header
The command header field is fixed - SIMBAL.
Access Number
Enter the communication providers access number for
SIM card balance enquiries.
•
Optus = 9999
•
Vodafone = 1555 / 1512
•
Telstra = #100#
•
Virgin = 225
Text
Enter the text required by the communication providers
to obtain your SIM card balance (Max = 16 characters). In
Australia, examples may change and include:
•
Optus = Balance
•
Vodafone = Blank Message
•
Telstra = Voice Call
•
Virgin = Bal
Preamble
Enter text to search for the credit remaining on your SIM
card (eg. if Vodafone Australia displays ‘U’ve Remaining:
365 day: $35.53 Exp: 09/11/2015’ enter ‘Day:’ as the pream
ble).
Minimum Amount
Enter the minimum balance to filter GSM module SIM card
balance enquiries. This allows the GSM module to only
forward an SMS balance alert message to your mobile
telephone when the SIM card balance falls below the
minimum amount set here.
Days
This parameter sets how often the GSM module will
automatically request a SIM card balance. This can be set
between 001 and 255 days / 000 = disabled.
Mobile
This parameter allows you to program which mobile
telephone number the GSM module will forward the SIM
card balance enquiry of the GSM module to.
Expire Reminder
Enter the number of weeks for the GSM module to remind
you to recharge your GSM SIM card (01 to 99 weeks / 00 =
disabled).
Example
The example below is requesting a SIM Balance of the SIM
card connected to the Vodafone network (Australia) with a
reminder that the credit available on the SIM card requires
a recharge in 25 weeks using a 180 day prepaid SIM card.
The SIMBAL requests a balance enquiry every two days
when the balance falls below $20.00.
SIMBAL,2580,1555,Day,$20.00,002,0414123456,25
After 25 weeks, the GSM module will send the following
SMS, ‘SIM is about to expire please recharge immediately’.
Information in this example is correct at time of print
ing. Check with your telco carrier as these options may
change.
Installer Reference Guide
5
Bosch Security Systems 07/15 CM744BIRG FTR1.1
Description
SMS String
Arming / Disarming Areas
Turning Area 1 On
,AREA,1,ON
Turning Area 1 On With Confirmation
,AREA,1,ON,CONFIRM
Turning Area 1 Part 1 On
,AREA,1,PART 1
Turning Area 1 Part 1 On With Confirmation
,AREA,1,PART 1,CONFIRM
Turning Area 1 Part 2 On
,AREA,1,PART 2
Turning Area 1 Part 2 On With Confirmation
,AREA,1,PART 2,CONFIRM
Turn Multiple Areas On
,AREA,1,2,3,4,ON
Turn All Areas On That the User Belongs To
,AREA,ON
Turning Area 1 OFF
,AREA,1,OFF
Turning Area 1 OFF With Confirmation
,AREA,1,OFF,CONFIRM
Check Area Status
,AREA,1,STATUS
Check Status Of Multiple Areas
,AREA,1,2,3,STATUS
Turning Outputs On/Off
Turn Output 1 On
,OUTPUT,1,ON
Turn Output 1 On With Confirmation
,OUTPUT,1,ON,CONFIRM
Turn Multiple Outputs On
,OUTPUT,1,2,3,4,ON
Turn Multiple Outputs On With Confirmation
,OUTPUT,1,2,3,4,ON,CONFIRM
Turning Output 1 OFF
,OUTPUT,1,OFF
Turning Output 1 OFF With Confirmation
,OUTPUT,1,OFF,CONFIRM
Turning Multiple Outputs OFF
,OUTPUT,1,2,3,4,OFF
Turning Multiple Outputs OFF With Confirmation
,OUTPUT,1,2,3,4,OFF,CONFIRM
Check Output Status
,OUTPUT,1,STATUS
Check Status Of Multiple Outputs
,OUTPUT,1,2,3,4,STATUS
Locking and Unlocking Doors
Unlock Door 1
,DOOR,1,UNLOCK
Unlock Door 1 With Confirmation
,DOOR,1,UNLOCK,CONFIRM
Unlock Multiple Doors
,DOOR,1,2,3,UNLOCK
Unlock Multiple Doors With Confirmation
,DOOR,1,2,3,UNLOCK,CONFIRM
Lock Door 1
,DOOR,1,LOCK
Lock Door 1 With Confirmation
,DOOR,1,LOCK,CONFIRM
Lock Multiple Doors
,DOOR,1,2,3,LOCK
Lock Multiple Doors With Confirmation
,DOOR,1,2,3,LOCK,CONFIRM
Check Status Of A Door
,DOOR,1,STATUS
Check Status Of Multiple Doors
,DOOR,1,2,3,STATUS
Check System Status
,SYSTEM,STATUS
SIM Balance Check - Must have been configured under site settings
Check Current SIM Balance
,SIMBAL,,,,,,
Installer Reference Guide
6
Bosch Security Systems 07/15 CM744BIRG FTR1.1
Page Intentionally Blank
Installer Reference Guide
7
Bosch Security Systems 07/15 CM744BIRG FTR1.1
CM744B Specifications
Part Number:
CM744B - 3G GSM/GPRS/SMS Radio Module
Reporting Formats:
SMS via GSM , CSV-IP via GPRS and Conettix Format via GPRS are supported.
iFob app and RAS will be available via a future panel firmware update. Check with your distributor for availability.
The CM744B does not support Contact ID (CID) over GSM.
SIM Card Type:
Dual standard size SIM cards.
When using the module in single SIM mode the SIM card should be installed in SIM 1 socket.
Antenna:
Quad Band Omni Directional Adhesive Antenna with integrated lead and SMA Connector. 3dbi gain - 50 ohm
Operating Environment:
0˚ to 55˚C RH 5 to 85% at 30˚C non-condensing.
Fixing Method:
The CM744B is mounted directly to the expansion port on the control panel PCB. Three plastic standoffs are sup
plied to support the module and these should be connected to the control panel before installing the CM744B.
Warranty:
3 years from date of manufacture (return to base)
In the interest of ongoing product development this
document is subject to change without notice.
Bosch Security Systems
Level 2, 21 Solent Circuit
Baulkham Hills, NSW 2153
Australia
Phone: +61(2) 9842 4743
Facsimile: +61(2) 8850 2230
© 2015 Bosch Security Systems