Daikin Urusara 7 FTXZ-N Series Engineering Data

File Specifications

Brand: Daikin
Category: Heat Pump
Model: Urusara 7 FTXZ-N Series (Engineering Data), prTF620OtNRgM
File Type: PDF
File Size: —
Pages: 92 pages

Download PDF

Download Daikin Urusara 7 FTXZ-N Series Manual (92 pages)

Read Online:

Read the Daikin Urusara 7 FTXZ-N Series Engineering Data online using the built-in PDF viewer.

Key Pages of Document

Split Type Air Conditioners FTXZ-N Series

1 Split Type Air Conditioners FTXZ-N Series 1. Power Supply..........................................................................................2 2. Functions.................................................................................................3 3. Specifications............................ ...

Split Type Air Conditioners FTXZ-N Series

1. Power Supply Note: Power Supply Intake ; Outdoor Unit Indoor Unit Outdoor Unit Power Supply FTXZ25NVMM RXZ25NVM 1 φ, 220 - 230 - 240 V, 50 Hz 1 φ, 220 - 230 V, 60 Hz FTXZ35NVMM RXZ35NVM FTXZ50NVMM RXZ50NVM ...

Split Type Air Conditioners FTXZ-N Series

3 2. Functions Category Functions FTXZ25/35/50NVMM RXZ25/35/50NVM Category Functions FTXZ25/35/50NVMM RXZ25/35/50NVM Basic Function PAM control � Health and Cleanliness Titanium apatite photocatalytic air-purifying filter — Swing compressor � Reluctance DC motor � Photocatalytic air-purif ...

Split Type Air Conditioners FTXZ-N Series

3. Specifications 50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V Note: � The data are based on the conditions shown in the table below. Model Indoor Unit FTXZ25NVMM FTXZ35NVMM Outdoor Unit RXZ25NVM RXZ35NVM Cooling Heating Cooling Heating Capacity Rated (Min. ~ Max.) kW 2.45 (0.6 ~ 3.9) 3 ...

Split Type Air Conditioners FTXZ-N Series

5 50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V Note: � The data are based on the conditions shown in the table below. Model Indoor Unit FTXZ50NVMM Outdoor Unit RXZ50NVM Cooling Heating Capacity Rated (Min. ~ Max.) kW 4.95 (0.6 ~ 5.8) 6.3 (0.6 ~ 9.4) Btu/h 16,900 (2,000 ~ 19,800) 21,500 (2 ...

Split Type Air Conditioners FTXZ-N Series

4. Dimensions 4.1 Indoor Unit FTXZ25/35/50NVMM 4.2 Outdoor Unit RXZ25/35/50NVM THE MARK (→) SHOWS PIPING DIRECTION AIR FLOW (INDOOR) REQUIRED SPACE 798 MIN.30 (SPACE FOR PERFORMANCE) DISTANCE FROM WALL DISTANCE FROM WALL 372 OPERATION LAMP 370 NAME PLATE TIMER LAMP TRANSMITTER / RECEIVER 295 ...

Split Type Air Conditioners FTXZ-N Series

7 5. Wiring Diagrams 5.1 Indoor Unit FTXZ25/35/50NVMM 5.2 Outdoor Unit RXZ25/35/50NVM CAUTION M1S M4S M5S M3S M2S FIELD WIRING. outdoor MSW MSW MSW MSW MSW A1P~A4P A6P, A7P C104, C105 FG1 F1U F1UT H1P, H2P H4P, H5P S1C S2C M1F M1S~M8S MR10 R1T, R2T R1V S16~S401 CN403, B401 S1W X1M 1 2 3 BLU ...

Split Type Air Conditioners FTXZ-N Series

6. Piping Diagrams 6.1 Indoor Unit FTXZ25/35/50NVMM 6.2 Outdoor Unit RXZ25/35/50NVM INDOOR UNIT HEAT EXCHANGER CROSS FLOW FAN 6.4CuT M FAN MOTOR FIELD PIPING (6.4CuT) SINGLE UNION JOINT 9.5CuT FIELD PIPING (9.5CuT) SINGLE UNION JOINT REFRIGERANT FLOW COOLING HEATING 4D086882 ROOM TEMPERAT ...