Deister electronic LogIdent UDL500 Wiring & Installation Instructions
File Specifications
| Brand: | Deister electronic |
| Category: | Rfid Systems |
| Model: | LogIdent UDL500 (Wiring & Installation Instructions), pr6fY.tPQ2AXQ |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 36 pages |
Download PDF
Download Deister electronic LogIdent UDL500 Manual (36 pages)Read Online:
Read the Deister electronic LogIdent UDL500 Wiring & Installation Instructions online using the built-in PDF viewer.
Key Pages of Document
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH. deister electronic GmbH reserves the right to ma ...
2. Connectors...................................................................5 2.1 Installation note..................................................................................................5 2.2 Pin assignment UDL500........................................... ...
Dimensions (mm): 640 x 280 x 75 Housing material: ABS/PMMA, ALUMINUM, V2A Color: silver Protection class: IP65 Operating temperature: -20 ... +70°C Storing temperature: -40 ... +85°C Relative humidity: 5% ... 95% non condensing Voltage supply: 10 ... 30V/DC Power consumption: 10W (during operation) 2W (standby) Transmission frequency: 865 ...
Attention: It is important to take care that the marked tab connector is connected to the supplied cable plug. The device always needs to be professionally grounded using a yellow/green flexible line with a minimum profile of 0.75mm². V17/01/08 deister electronic GmbH 30890 Barsinghausen Germany 5 Wiring & Installation ...
document are intended to be performed by technical professionals only. 2.2 Pin assignment UDL500 Pin Name Function 1 – not connected 2 GND ground 3 +10 ... 30V/DC voltage supply +10 ... 30V/DC 4 OUTGND external ground for digital output 5 OUT digital output voltage, max. +48V/DC, I<300mA 6 ...
Installation notes: We recommend professional grounding of the device (see 2.1 Installation note). Output OUT and Input IN are potential-free. Take care that the grounding will be sufficient (use second tab connector)! The potential-free input IN may be used to control the reader by a hardwa ...
Installation notes: We recommend professional grounding of the device (see 2.1 Installation note). Output OUT is potential-free. Take care that the grounding will be sufficient (use second tab connector)! The reader can be controlled by a trigger signal via software. Therefore, it is not necessary to us ...
Most RS485-buses require termination resistors across the conductor pair. The need for termination has to be checked for each installation. Especially for high data rates, steep edges or long cables termination resistors are absolutely mandatory. Only both ends of the main cable, i.e. at the first and the last device, require termination r ...
4.1 UDL500 housing All dimensions in mm: 10 deister electronic GmbH 30890 Barsinghausen Germany V17/01/08 Wiring & Installation Instructions UDL500 ...
Deister electronic LogIdent UDL500 user guide recommended for: MDR-3021AT, TWN4 Palon Compact LEGIC, Quantum II RFID ECU, RD-20, TWN3 Multi ISO.
⚠️ Download Safety
The Rfid Systems Wiring & installation instructions (36 pages) is completely safe to download (last scan date: 25/06/2026).
Related PDF Instructions for Deister electronic LogIdent UDL500:
-
Deister electronic RDL150 RS485 Card Reader Wiring and installation instruction, 20 pages
-
Deister electronic UNIKON CHAMP Pet Care Product Wiring & installation instructions, 16 pages
-
Deister electronic UDL5 Mouse Quick start manual, 22 pages
-
Deister electronic LogIdent UDL500 Rfid Systems Wiring & installation instructions, 36 pages
-
Deister electronic LCA 500 Marine Radio Wiring and installation instructions, 20 pages
-
Deister electronic amanTag deActivator Protection Device Manual , 8 pages