Deister electronic LogIdent UDL500 Wiring & Installation Instructions

File Specifications

Brand: Deister electronic
Category: Rfid Systems
Model: LogIdent UDL500 (Wiring & Installation Instructions), pr6fY.tPQ2AXQ
File Info: Adobe Acrobat PDF (DjVu)
File Size: —
Pages: 36 pages

Download PDF

Download Deister electronic LogIdent UDL500 Manual (36 pages)

Read Online:

Read the Deister electronic LogIdent UDL500 Wiring & Installation Instructions online using the built-in PDF viewer.

Key Pages of Document

© Copyright 2008 by deister electronic GmbH

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH. deister electronic GmbH reserves the right to ma ...

1. Technical Data............................................................4

2. Connectors...................................................................5 2.1 Installation note..................................................................................................5 2.2 Pin assignment UDL500........................................... ...

1. Technical Data

Dimensions (mm): 640 x 280 x 75 Housing material: ABS/PMMA, ALUMINUM, V2A Color: silver Protection class: IP65 Operating temperature: -20 ... +70°C Storing temperature: -40 ... +85°C Relative humidity: 5% ... 95% non condensing Voltage supply: 10 ... 30V/DC Power consumption: 10W (during operation) 2W (standby) Transmission frequency: 865 ...

2.1 Installation note

Attention: It is important to take care that the marked tab connector is connected to the supplied cable plug. The device always needs to be professionally grounded using a yellow/green flexible line with a minimum profile of 0.75mm². V17/01/08 deister electronic GmbH 30890 Barsinghausen Germany 5 Wiring & Installation ...

The procedures and working activities described in this

document are intended to be performed by technical professionals only. 2.2 Pin assignment UDL500 Pin Name Function 1 – not connected 2 GND ground 3 +10 ... 30V/DC voltage supply +10 ... 30V/DC 4 OUTGND external ground for digital output 5 OUT digital output voltage, max. +48V/DC, I<300mA 6 ...

2.4 UDL500: Control digital output via hardware trigger

Installation notes: We recommend professional grounding of the device (see 2.1 Installation note). Output OUT and Input IN are potential-free. Take care that the grounding will be sufficient (use second tab connector)! The potential-free input IN may be used to control the reader by a hardwa ...

2.5 UDL500: Control digital output via software trigger

Installation notes: We recommend professional grounding of the device (see 2.1 Installation note). Output OUT is potential-free. Take care that the grounding will be sufficient (use second tab connector)! The reader can be controlled by a trigger signal via software. Therefore, it is not necessary to us ...

3. RS485 interface

Most RS485-buses require termination resistors across the conductor pair. The need for termination has to be checked for each installation. Especially for high data rates, steep edges or long cables termination resistors are absolutely mandatory. Only both ends of the main cable, i.e. at the first and the last device, require termination r ...

4. Mechanical dimensions

4.1 UDL500 housing All dimensions in mm: 10 deister electronic GmbH 30890 Barsinghausen Germany V17/01/08 Wiring & Installation Instructions UDL500 ...

Deister electronic LogIdent UDL500 user guide recommended for: MDR-3021AT, TWN4 Palon Compact LEGIC, Quantum II RFID ECU, RD-20, TWN3 Multi ISO.

⚠️ Download Safety

The Rfid Systems Wiring & installation instructions (36 pages) is completely safe to download (last scan date: 25/06/2026).

Related PDF Instructions for Deister electronic LogIdent UDL500: