Microcontroller-controlled temperature difference controller for solar thermal systems

Operating manual Operating manual Solareg II VISION plus all-guides com ...

Application area / device features

3 1.1 Application area 3 1.2 Device features 3 2 Safety instructions 3 3 Mounting the device 4 3.1 Opening the device 4 3.2 Wall mounting 4 3.3 Connections 5 3.4 Temperature sensor connection 5 4 Short descriptions and device operation 5 4.1 Display layout 5 4.2 Operating the device 6 5 Menu structure 6 5.1 "Info ...

Application area / device features

1.1 Application area SOLAREG II VISION plus controllers are high-performance microprocessor-control- led units for controlling the functions of solar thermal systems. The SOLAREG II VISION plus perfectly controls solar power systems equipped with up to two collectors or two storage tanks and can be used for numerous sy ...

Mounting the device

3.1 Opening the device Prior to opening the device, make sure to disconnect the mains voltage and ensure that it cannot be switched back on again! The upper part of the housing is locked to the lower part using two latches. Pull the side pieces (cover plates) of the upper part of the housing outwards (see picture) to unlatch it and up ...

The following points must be followed for the 230V connections:

In case of a fi xed mains connection, there must be a switch installed outside the controller that can disconnect the device from the mains power supply. This switch is not required if the mains supply is connected using a cable and an earthed mains plug. The controllers are d ...

4.2 Operating the device

The SOLAREG II controller is convenient and easy to operate using four operating buttons. Using the operating buttons, you can: Access display values Perform device settings The graphic display symbols allow you to easily navigate through the operating structure. The operating buttons have the following functions: Operating buttons ...

Temperature diff erence controller for heat

consumer No 25°C Anti-freeze protection sensor (T1 – T6 adjust- able) Displays general temperature measur- ing point (T6) (hidden, if not connected) No 1234 h Operating hours for charging storage tank Can be reset to 0 h Yes 927 kWh Energy yield for storage tank Can be r ...

2 – 35K

3K min 0:00 1(2,3) Time frame1(2,3): Start 0:00 – 23:59 0:00 max 23:59 1(2,3) Time frame 1(2,3): Stop 0:00 – 23:59 23:59 min 6:00 4 Time frame1(2,3): Start for tube collector function 0:00 – 23:59 6:00 max 20:00 ...

Value range Factory

setting Current setting Line Value 4 0 Tube collector function, time-controlled 0 = Off 1 = On 0 = Off 5 0 Function Energy yield measure- ment 0 = Off 1 = On 0 = Off 6 0 Energy yield measure- ment Sets glycol type 0 – 10 0 7 50 Energy yield measure- ment Glycol mixture 0 – 100% 5% incre- ments 50 8 1.0 Energy yield m ...

6.1 Diagram 0: 1 collector, 1 storage tank

S1 S2 S5 S4 S7 A1 PE S1 L N N A1 S2 S7 S3 S4 S5 S6 N A2 N A3 230V connections L Mains phase N Neutral conductor - mains and outputs A1 Solar circuit pump (switching output 1) A2 No function A3 Independent controller (switching output 3) Sensor connections S1 Collector sensor S2 Lower storage tan ...