Doran 2200CW Technical Manual

File Specifications

Brand: Doran
Category: Touch Panel
Model: 2200CW (Technical Manual), prZtzuA1JdQEs
File Type: PDF
File Size: —
Pages: 65 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (65 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 27/03/2026).

Read Online

Read the Doran 2200CW Technical Manual online using the built-in PDF viewer.

Key Pages of Document

Digital Checkweighing Indicator

Technical Manual MAN347 – Rev E Doran Scales, Inc. www.doranscales.com ...

Table of Contents

Scale Setup ............................................................................................................................ 1 Unpacking Your Scale .....................................................................................................................1 Specifications ........................................................................................................................ 2 Scale Controls and Operat ...

Time and Date ..................................................................................................................... 13

Setting Time and Date .................................................................................................................. 13 Accumulator and Counter .................................................................................................... 14 Accumulator and Counter Operation ....................... ...

4-20mA Analog Output Option ............................................................................................ 50

Wired Ethernet Option ........................................................................................................ 51 Wireless 802.11b/g Ethernet Option .................................................................................... 52 Bluetooth Option .................................................................. ...

Thank you for purchasing a Doran Scales product. Please read this manual to ensure

obtaining all the benefits that the indicator can provide. If any questions arise, please contact the Doran Scales Technical Support Department at 630-879-1288. Unpacking Your Scale Before unpacking your Doran scale, please read the instructions in this section. Your new scale is a durable industrial product, but it is also a sensitive weighing instrument. No ...

Class III – 10,000d; Cert. #06-101

CWM Certificate Class III – 10,000d; Cert. #AM-5617 Enclosure 304 Stainless Steel Product Dimensions 10” W x 6.75” H x 3.5” D Environmental Protection IP69K Legal for Trade Temperature Range 14 F to 104F (-10 C to +40 C) Resolution Range 200d to 100,000d Analog Signal Sensitivity 0.16 V/e minimum, 0.5 V/e typical System Linearity 0.01% full scale Analog Signal Range -0.5mV ...

Scale Controls and Operation

Fig. 1: Front Panel Scale Annunciators Unit of measure lb, oz, kg, g or lb:oz. The units annunciator to the right of the display will indicate the current unit of measure. Net weighing mode is indicated by the NET annunciator. The annunciator will illuminate when a net weight is displayed. When not illuminated, a gross weight is displayed. Battery option status indicator. When the annunciator illuminates, the battery charg ...

Motion indicator. This symbol represents motion or instability of the

weight. The annunciator will illuminate when motion is sensed on the platform. Changes in weight, vibration or air currents can cause the scale to go into motion. Under illuminates to indicate weight is below the Under target and above the Low target or flashes if below the Low target. Accept illuminates to indicate weight is at or above the Under target and at or below the Over tar ...

Place the item you wish to tare on the scale platform and press TARE. The scale will

display a net weight and the NET annunciator will illuminate. Tare weights will remain in memory even if the indicator is turned off. Keyboard TARE entry Enter a weight and press TARE to save or press CLEAR to cancel tare entry. The scale will display a net weight and the NET annunciator will illuminate. Display TARE value To display the current tare value, press ...

Password Protected Values

To activate password protection, the PASS parameter must be configured with a numeric password. Once configured, password protection will be activated upon power up. If password protection is activated, the display will show PASS when SETPOINT, TARE, UNDER, or OVER values are displayed. Password protection also inhibits deletion or creation of new product IDs. Enter the password and press ENTER, the display will then show PAS ...

The indicator can be optionally configured with a self-contained Rechargeable Sealed

Lead-Acid battery and charging circuit, both internal. The scale is designed to run continuously for up to 60 hours with a single 350 ohm load cell. To maximize battery life, leave the auto-off timer enabled which will automatically power down the scale after a period of non-use. Power Off 1) Manual - Press and hold the ZERO push button until the displ ...

Three Band Checkweighing

Three band checkweighing classifies weighments into over, accept and under. The default configuration is three band checkweighing. Note that lb:oz is not supported for checkweighing limits. Three Band Checkweighing (C.o. set to operation starting with 3) 1. Remove all items from the scale platform 2. Press ZERO and the display will read zero weight 3. Place an item on the scale platform and wait for the scale to stabilize 4. Acce ...

Five Band Checkweighing

Five band checkweighing classifies weighments into high, over, accept, under and low. Note that lb:oz is not supported for checkweighing limits. Five Band Checkweighing (C.o. set to operation starting with S) 1. Press ZERO 2. Place an item on the scale 3. Checkweigh status is indicated as follows a. Flashing OVER = HIGH b. Solid OVER = OVER c. Solid ACCEPT = ACCEPT d. Solid UNDER = UNDER e. Flashing UNDER = LOW Enter and Display o ...

Weight Reference Entry of High and Low Limits (C.E. set to Pb)

1. Press ZERO 2. Place an item of the desired weight on the scale platform 3. Press and hold the OVER or UNDER until the display reads High or louu respectively 4. The display will briefly read over or underfollowed by the weight on the platform and checkweigh status annunciators will flash 5. Press either OVER to increase the weight value or press UNDER to decrease the weight value. Pressi ...

1200 product IDs are available. Deploying a large library of IDs with multiple scales can

be easy to manage with Doran’s data management programs. Product IDs save information that includes:  Checkweigh limits  Unit of measure  Accumulator and counter values  Tare  Two 40 alphanumeric character fields  Number of samples and alarm timer for QC Weigh  Motion Aperture (nn.A.)  Threshold (tHs)  Checkweigh operation ( ...

To enter and save values for all fields associated with the current Product ID, enter

values for each field. When changing products, the display will read SaVed to indicate the all fields associated with the new Product ID number are saved and will be recalled when that product is used again. Delete PRODUCT ID from Memory Enter the product ID to be deleted and press PROD ID. The display will show pRd Id, followed by the product ID number. Press and hol ...

Time and Date

Setting Time and Date To change the date: 1. Press and hold decimal point / clock button until date is displayed 2. The display flashes the current the date 3. The digits being edited flashes on the display 4. Enter the date with leading zeros in the format MM.DD.YY 5. Press UNITS to advance to the next digit 6. Press UNITS until the display reads saved to confirm the date changes are saved 7. Press ENTER to return to the normal weighing m ...

Accumulator and Counter

Accumulator and Counter Operation When a manual or automatic print function is executed, the accumulator has the currently displayed weight added to its’ current value and the counter is incremented. To accumulate automatically, select an auto print function in the parameter setup menu. To accumulate manually, allow the scale to become stable and press PRINT. The maximum value that can be shown for the accumulator and counter i ...

Fig. 2: Motherboard Layout

Removing and Replacing the Rear Panel Before you remove the rear panel, remove AC power. Power down the scale if the optional battery power is present. Removing the rear panel requires a 5/16” nut driver. To replace the rear panel and achieve a tight seal, each screw requires a rubber bonded washer and the gasket needs to be in place. Tighten screws to 20 in-lb to achieve proper sealing. Tighten all wat ...

Related Devices for Doran 2200CW:

SMARTLINK 360SLT2
Doran SMARTLINK 360SLT2
02.09.2026 18 pages

MANUFACTURING LLC Please Read This Manual Carefully Before Using This Product 360SLT2 SMARTLINKTM TPMS TABLET USER MANUAL Setup and usage guide for the Doran SMARTLINK 360SLT2 Measuring Instruments. This guide provides technical guidance on power requirements, performance optimization, basic operation.

4300
Doran 4300
23.03.2026 12 pages

OPERATOR MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. BATAVIA, IL 60510 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 4.0 MAN User guidebook for the Doran 4300 Scale. This manual covers control functions, security instructions, cleaning instructions, troubleshooting.

GuardianXL
Doran GuardianXL
11.03.2026 87 pages

DIGITAL WEIGHT INDICATOR AND CONTROLLER INSTALLATION AND INSTRUCTION MANUAL DORAN SCALES, INC. 1315 Paramount Parkway Batavia, Illinois 60510 800-262-6844 www.d Instruction reference guide for the Doran GuardianXL Kitchen Appliances. It includes maintenance procedures and product maintenance, reset instructions, wiring diagrams.

4300
Doran 4300
14.08.2026 130 pages

INSTRUCTION MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. BATAVIA, IL 60510 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 4.0 User support manual for the Doran 4300 Scales. The guide offers support information and assembly reference, product specifications, system configuration.

7000XL
Doran 7000XL
05.09.2026 5 pages

Digital Scale Digital Weight Indicator OPERATOR MANUAL DORAN SCALES INC. 1315 PARAMOUNT PKWY. 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANU Installation and maintenance guide for the Doran 7000XL Scales. This manual provides guidance on maintenance schedule, safety guidelines, software configuration.

300
Doran 300
30.07.2026 37 pages

Digital Bench Scale INSTRUCTION MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 2. Device technical manual for the Doran 300 Scales. This guide provides technical guidance on adjustment procedures, product specifications, troubleshooting, operating conditions.

PC200
Doran PC200
03.06.2026 23 pages

Digital Portion Control Scale Instruction Manual DORAN SCALES INC. 1315 PARAMOUNT PKWY. BATAVIA, IL. 60510 1-800-262-6844 FAX: (630)879-0073 http://www.doransc Complete instruction guide for the Doran PC200 Scales. This documentation covers connectivity options, safety, installation support.

4100XL
Doran 4100XL
07.08.2026 33 pages

Digital Checkweigher Scale INSTRUCTION MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVIS Usage and setup manual for the Doran 4100XL Scales. This documentation explains configuration and dimensions and layout, adjustment procedures, technical overview, firmware updates.

Touch Panel: Frequently Requested PDF Instructions

Fridge-tag 2
berlinger Fridge-tag 2
03.09.2026 7 pages

Quick Info - User Guide EN r ing. e 88 11 com V1_052018 internal/external sensor User Guide Fridge-tag® 2 Product setup manual for the berlinger Fridge-tag 2 Other. It provides instructions for application scenarios, regulatory notices, service contacts, setup instructions.

PPC010 EC
VIPA PPC010 EC
17.05.2026 70 pages

PPC | 67K-RRJ0 | Manual HB160 | PPC | 67K-RRJ0 | en | 18-30 VIPA HMI Panel PC - PPC010 EC www.vipa.com/en/service-support/manuals User setup guide for the VIPA PPC010 EC Touch Panel. The manual includes instructions for usage examples, setup validation, detailing setup, system configuration.

DOP-107EG
Delta DOP-107EG
11.05.2026 2 pages

DOP-107EG High color ‧ Wide screen ‧ User-friendly Delta Electronics Inc, No.18, Xinglong Rd., Taoyuan City 33068, Taiwan Instruction Sheet (1) General prec Instruction booklet for the Delta DOP-107EG Control Panel. It details device setup and technical troubleshooting, shutdown procedures, network configuration.

TP 605CQ-2
VIPA TP 605CQ-2
21.07.2026 62 pages

Manual VIPA HMI Touch Panel 605-3B1S0 Order no.: VIPA HB160E_TP Reference: RE_605-3B1S0 Rev. 09/09 This manual is part of the documentation package with order n Product operation guide for the VIPA TP 605CQ-2 Touch Panel. This guide explains the features and service instructions, connectivity options, internal layout.