Focus V3 Operation & User’s Manual

Text of the manual

This guide will teach you how to use your Foc.us V3 brain stimulator.

If you are new to brain stimulation you may be nervous. Don’t be. Right now your brain is full of electrical flows. Stimulation simply lets you alter those flows a little. Read the warning below and provided you have none of the listed contra-indicat

YOUR FOC.US V3

Understand the different parts included with your V3 brain stimulator. ● ● Always store your V3 in the supplied case when not in use. Squeeze any excess liquid from the sponges and place them in the electrodes. Ensure the lid of the supplied water bottle is tightly closed before returning to its place. ● ● The silicone electrodes can b

Included with V3.......................................................................................................... 3

Navigating your V3 ...................................................................

NAVIGATING YOUR V3

5 PRESS to turn ON PRESS the blue joystick to turn on and start. Navigate your Foc.us V3 with the blue joystick. Use DOWN to select TAKE CHARGE PRESS to start your journey 1. Value & Labels This shows that the current current setting is 1.5mA. Use LEFT to reduce or RIGHT to increase this value. Then PRESS or DOWN to proceed to next setting

V3 ELECTRICAL BRAIN STIMULATOR

6 Your Foc.us V3 is an electrical neuro-stimulator which will deliver a controlled current to your brain. The theory of transcranial Electrical Stimulation (tES) is that by passing a current through your brain, the excitation levels of your brain cells are altered. The delivered current is small compared to the current that is

QUICK START GUIDE

7 Prepare Electrodes Position the amx-y electrodes with wet sponges in the headband and place headband on head. Liberally wet the sponges before use. 1. Start a Program A program defines the target current, duration and mode settings to be used in a stimulation session. V3 ships with 7 Programs: Ripple, 3rd eye, wave, pulse, Noise, eDream &

The effects of tES depend on the positioning and polarity of the electrodes. Anodal stimulation

induces an increase in cortical excitability under the X electrode. Cathodal stimulation induces an increase in cortical inhibition under the Y electrode. When electrodes are placed on the shoulder or arm, the exact location is less importan

ELECTRODE SETUP DETAILS

9 Wet sponges in amx-y Headband On Head To pass an electric current through your brain an electrical circuit must be setup between the device, cable, electrodes, sponges and you. Sponges should be wet. Use the small water bottle to keep water handy. Be careful not to touch the black silicone as this can result in electrical burns. Pla

V3 STIMULATION MODES

What is a mode? The mode describes the shape of the electrical signal. At a minimum V3 includes tDCS, tACS, so- tDCS, tPCS, tRNS and tRCS modes. Each mode has a set of parameters that control the shape of the electrical output. During a stimulation session the display of the V3 functions as an oscilloscope. It shows the real- time curre