KEYA TRONIC PRO Manual
Text of the manual
Open and close by 4-digit code. The code is erased every time the lock is opened, being available for
a new use.
1
Open and close by 4-digit code. The code is set for 1 user only.
2
Single User mode
To close:
To open:
To close:
The latch closes automatically after 2 seconds.
Note: the lock is provided with a metal latch holder
that allows to
Introduce the 5 digit Master code and press Enter
Close the lock by pressing Enter before 30s.
The User code is not deleted.
Change the User code
3
Press Enter during 3 seconds.
Introduce Current code and press Enter.
Introduce New code and press Enter.
CURRENT code NEW code
press during 3 seconds
Open using
Change the Master code
NEW master code
CURRENT master code
press during 3 seconds
Press Enter during 3 seconds.
Introduce Current master code and press Enter.
Introduce New master code and press Enter.
Open using electronic Master key: Inspection mode/ Delete User code
INSPECTION MODE
DELETE USER CODE
Connect the Master key (BLUE)
Programmable settings ( management software and cable required )
AUTOMATIC OPENING TIME:
The lock will open automatically at the programmed time:
- hh : mm
- Mon, Tue, Wed, Thu, Fri, Sat, Sun
- Working days
- Two options: Leave door open
Close door again
ACOUSTIC SIGNAL VOLUME:
- High/Low/Off
LED INDICATION OF CLOSED PO
Salt spray test
> 96h
Working temperature
-5°C < > +70°C
Latch force
> 45Kgf
UV Rays
> 10000h
Vibration
10 - 200 Hz 2g
Life test
> 200000 cycles
Electrostatic discharge
8000 V
Battery life
> 70000 cycles
Torx T20
4 x AA(LR6)
Measurements
TRONIC PRO
Batteries replacement
IMPORTANT: The batteries replacement
must be done in less than