Honeywell ADEMCO VISTA SERIES Programming Manual

File Specifications

Brand: Honeywell
Category: Security System
Model: ADEMCO VISTA SERIES (Programming Manual), pr1v2096o7G9s
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 48 pages

Download PDF

Download Honeywell ADEMCO VISTA SERIES Manual (48 pages)

Read Online:

Read the Honeywell ADEMCO VISTA SERIES Programming Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

1. Entry Delay No. 1 and No. 2 (fields ∗35, ∗36) cannot be greater than 30 seconds for UL Residential Burglar Alarm installations, and

entry delay plus dial delay should not exceed 1 minute. For UL Commercial Burglar Alarm installations, total entry delay may not exceed 45 seconds. 2. For UL Commercial Burglar Alarm and UL Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60 seconds. 3. The maximum number of reports per armed period (field ∗93) must be set to “0” (unlimited) for UL installations. 4. Periodic testing (see sche ...

1. Entry Delay No. 1 and No. 2 (fields ∗35, ∗36) cannot be greater than 30 seconds for UL Residential Burglar Alarm installations, and

entry delay plus dial delay should not exceed 1 minute. For UL Commercial Burglar Alarm installations, total entry delay may not exceed 45 seconds. 2. For UL Commercial Burglar Alarm and UL Residential Burglar Alarm installations with line security, total exit delay time must not exceed 60 seconds. 3. The maximum number of reports per armed period (field ∗93) must be set to “0” (unlimited) for UL installations. 4. Periodic testing (see sche ...

01 Delete Zone?

0 = No 1 = Yes 0 Deleting a Zone 0 = don’t delete zones 1 = go to next prompt to delete zones [∗] to continue To save the zone list, enter 0 and the system returns to the Zone List No. prompt. To delete a zone or zones in a zone list, enter 1 to continue. 01 Zn to Delete? (00 = Quit) 00 Delete the Zone 01-64† = zones to be deleted from list followed by [∗] to accept each zone 00 to continue Enter each zone to be deleted from the list, followed by [,]. After all zones to be deleted are entered, enter 00 to return to the Zone List No. prompt so that another list can be p ...

Zn ZT P RC IN: L

10 00 1 10 RF 1 Zone Programming ZT = see Zone Type chart shown in *56 Menu Mode “Zone Type” prompt P = partition 1, 2, 3 (common); RC = 1 (send CID report); 0 (no report) IN = input type; L = loop number [∗] to continue A summary screen with the selected zone’s current programming appears. Begin programming zone information as follows: • Enter Zone Type (ZT), Partition (P), Report Code (RC; 0-9 only; use *56 mode to enter hex codes), and Input Device Type (IN)* sequentially, but not the Loop No. (L). • Use the [A] (Advance) and [B] (Back) keys on the ...

WORKSHEET for SCHEDULES

(installer code + [#] + [6] [4]; master code can only access schedules 01-16 for VISTA-20P, 01-04 for VISTA-15P, and events 00-07 for both controls; VISTA-15P supports up to 8 schedules, VISTA-20P supports up to 32 schedules ) No. Event Device No. Group No. Partition Start Time/ Stop Time/ Repeat Random (see list below) for “01” events: for “02” events: for “04-06” events: Days Days (1-4) (yes/no) enter 01-18 enter 1-8 enter 1, 2, or 3 (VISTA-20P) 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Events: Master/ ...

Open Report Code

See above for entries. [0,0,0] System Reporting Note above *59. Part. 1 Part. 2 Common Sent upon disarming the system in the selected partitions. See UL ∗∗∗∗66 Arm Away/Stay Rpt Code See above for entries. [0,0,0,0,0,0] Away Stay Away Stay Away Stay Part. 1 Part. 2 Common This option allows for independent programming of Away and Stay reports for each partition, including the common lobby. NOTE: “OPEN” reports are not sent if the associated closing report is not enabled. ∗∗∗∗67 RF Trans. Low Bat Report Code See above for entries. ...

(Installer Code + [#] + [6] [4])

The system provides schedules, which can be used to automatically control 11 types of system events at pre-defined times. Some events are reserved for the installer only. VISTA-20P: Provides up to 32 schedules: 16 schedules for use by the end-user, 16 for use by the installer. VISTA-15P: Provides up to 8 schedules: 4 schedules for use by the end user, 4 for use by the installer. NOTES: • The master code can only access schedules 01-16 (VISTA-15P = 01-04) and events 00-07. • System clock must be set before schedules can take effect. • Pr ...

Honeywell ADEMCO VISTA SERIES user guide recommended for: LYNX, RPW303, 2092D - Waterproof Fire Safe, NFS2-640/E, NOTIFIER DSE3-23 Series.

⚠️ Download Safety

The Security System Programming manual (48 pages) is completely safe to download (last scan date: 10/12/2025).

Related PDF Instructions for Honeywell ADEMCO VISTA SERIES:

Security System Equipment: Frequently Requested

Have some Questions about Honeywell ADEMCO VISTA SERIES Device?

Get valuable and actionable advices from other Honeywell ADEMCO VISTA SERIES device users. Describe your problem or question, regarding the using of ADEMCO VISTA SERIES, in as much detail as possible, and other users will be able to answer you.