Tabel of Content

What’s in the Box 01 Feature Introduction 02 Setting Up the Camera and Monitor 03 Replacing the Camera lens 11 Safety 12 Customer service 15

What’s in the Box

Baby Camera (T8300-M) Baby Monitor (T8300-C) Camera Adapter (5V 2A) Monitor Adapter (5V 2A) Wall Mount Wide-Angle Lens Monitor Micro-USB Power Cable (1.5 m) Camera Micro-USB Power Cable (3 m) Mounting Screws User manual Feature Introduction Monitor Features: 6 5 2 1 3 4 9 10 8 12 11 13 7 1 Volume controls 8 microSD card slot 2 Screen 9 Support stand 3 Power button 10 Micro USB charging port 4 Menu button 11 LED indicator 5 Navigation buttons 12 Microphone 6 Return to previous level of menu / Talk button 13 Speaker 7 Monitor Antenna Press and hold the Talk button to speak to the camera. When Menu is opened, press Talk button once to return to previous level of menu. Press Power button to switch on / off the monitor screen. Press and hold the Power button for 2 seconds to switch on / off the monitor. Power adapter varies by region.

microSD memory card can only be used for firmware

upgrade, it cannot be used to store video recordings. Camera Features: 2 1 3 4 5 6 1 Standard camera lens 4 Speaker 2 Microphone 5 Micro USB port 3 Power LED Status indicator 6 Pairing button Setting Up the Camera and Monitor Monitor Installation Fully charge the monitor before use. To charge: Connect the baby monitor to the monitor adapter with the Micro USB cable, and then connect the adapter to a power outlet. Connect the other end of the baby monitor’s Micro USB power cable to the Micro USB port in the monitor to charge it. Press and hold the power button for 2 seconds to turn the baby monitor on. Camera Installation Connect the baby camera’s Micro USB power cable to the camera adapter (5V 2A), and then connect the adapter to a power outlet. Finally, connect the other end of the baby camera’s micro USB power cable to the micro USB port in the camera.

Press and hold the power button to power on the monitor.

Press the menu button to open Menu Settings. 1 Monitor Menu Settings Menu Options Description Available Options Brightness Set the brightness of the screen. Use the navigation buttons to adjust the brightness level Sleep Mode Select to turn off the screen after 1 min, 3 min, or 5 min. Off / 1 min / 3 min / 5 min Sound Alert Sound Level Note: You can set the baby monitor to alert you when a specific noise level is detected. Off / Level 1 / Level 2 / Level 3 / Level 4 / Level 5 Note: Level 1 has the best sensitivity. Alert Duration 10 Secs / 20 Secs / 30 Secs / 60 Secs Time Set the time on the monitor. Zoom Set the zoom level. Off / 1.5x / 2x Camera Add Camera Note: You can add up to 4 cameras per baby monitor. Delete Camera Delete / Cancel Cycle Cameras Note: Cycles through the list of connected baby cameras according to preset intervals. Off / 5 Secs / 10 Secs / 15 Secs / 30 Secs Night Vision Mode When enabled, the camera will change the screen color accordingly to the light conditions in the room. When disabled, the camera will stick to daylight screen color and will not change when the surrounding environment is getting dark. On / Off Anti-Screen Flicker Changes the refresh rate of the screen to prevent flickering. Mode A / Mode B

Replacing the Camera lens

Lens type Usage Lens Standard camera lens (default lens) This lens is recommended for general viewing; infants are clearly seen within a 2~3m range. The lens angle of view for standard camera lens is 62°. Wide-angle lens This lens provides a wide-angle view of the room. The lens angle of view for wide-angle lens is 110°. Back Front The standard camera lens is not removable. When you want to use the wide-angle lens, simply place it over the standard camera lens and fasten. Safety Warning Strangulation Hazard: Children have STRANGLED in cords. Keep this cord out of the reach of children (more than 1m (3ft) away). Never use extension cords with AC Adapters. Only use the AC Adapters provided. This product complies with the radio interference requirements of the European Community. Declaration of Conformity Hereby, Anker Innovations Limited declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.For the declaration of conformity, visit the Web site https:// www.eufylife.com/. This product can be used across EU member states. Due to the used enclosure material, the product shall only be connected to a USB Interface of version 2.0 or higher. The connection to so called power USB is prohibited. A statement regarding the AC/DC adapter as disconnect device is missing in the user manual. The statement shall require a socket outlet that is installed near equipment and that shall be easily accessible. The adapter shall be installed near the equipment and shall be easily accessible. Do not use the Device in the environment at too high or too low temperature, never expose the Device under strong sunshine or too wet environment. The suitable temperature for the product and accessories is -20°C-60°C. When charging, please place the device in an environment that has a normal room temperature and good ventilation. It is recommended to charge the device in an environment with a temperature that ranges from -10°C~40°C. Please ensure to use only the charger offered by the manufacturer. Using unauthorized charger may cause danger and violate the authorization of the projecter and the guarantee article. The charger output voltage/current is 5Vdc/2A. The plug considered as

disconnect device of adapter.

If you use a third-party charger, the recommended outputvoltage/current of the adaptor is 5Vdc/2A,and the adapter shall be CE approval type. CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS RF exposure information: The Maximum Permissible Exposure (MPE) level has been calculated based on a distance of d=20 cm between the device and the human body. To maintain compliance with RF exposure requirement, use product that maintain a 20cm distance between the device and human body. Operating Frequency Range: 2410-2477MHz CE SAR: The SAR limit of Europe is 2.0 W/kg. Device types T8300-M has also been tested against this SAR limit. The highest SAR value reported under this standard. This device was tested for typical hand held operations with the back of the device kept 0mm from the Limb. The following importer is the responsible party (contact for EU matters only) Importer:Anker Technology (UK) Ltd Importer Address:Suite B, Fairgate House, 205 Kings Road, Tyseley, Birmingham,United Kingdom B11 2AA This product is designed and manufactured with high quality materials and components, which can be recycled and reused. This symbol means the product must not be discarded as household waste, and should be delivered to an appropriate collection facility for recycling. Proper disposal and recycling helps protect natural resources, human health and the environment. For more information on disposal and recycling of this product, contact your local municipality, disposal service, or the shop where you bought this product. FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help. FCC Radio Frequency Exposure Statement The T8300-C device has been evaluated to meet general RF exposure requirements. The T8300-C can be used in fixed exposure condition. The min separation distance is 20cm. This T8300-M was tested for typical body‐worn operations with the back of the handset kept 0 mm from the body. RF Exposure Information(SAR) The Extremity SAR limit of FCC for Hand held is 4.0W/kg. Device is recommended to use in hand held only and SAR when hand held is 1.804W/kg Worn on body will have unexpected RF exposure RISK. The following importer is the responsible partyCompany Name: POWER MOBILE LIFE, LLC Address: 400 108th Ave NE Ste 400, Bellevue, WA 98004-5541 Telephone:1-206-383-8247