FBII Legend 100 Programming Manual
Read Online
Read the FBII Legend 100 Programming Manual online using the built-in PDF viewer.
Text of the manual
LEGEND - 100 INSTALLER
PROGRAMMING
LCD KEYPAD PROGRAMMING MANUAL
Revision
3.2
.
A Subsidiary of Pittway Corp.
163 Eileen Way, Syosset, NY 11791
(800) 645-5430
l (516) 921-8666
Fl2345A REV 4191
._. ,. ,, LEGEND-100 KEYPAD PROGRAMMING
MANUAL
~.
(\,
I
.Revision 3.1
,/-
/\ ’
CHAPTER 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
CHAPTER 2: Programming Mode -LCD Keypad . . . ..-. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 3: Display Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 4: Question Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CHAPTER 5: Question Selection Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CHAPTER 6: Programming Questions Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
CHAPTER 7: Programming Levels . . . . . . . . . . . . . . . . . . ,.........a....................................
CHAPTER 8: Sample Programming Session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
CHAPTER 9: Keypad Programming Questions .............................................. :..12
Programming Level .....................................
.12
CS Communications .....................................
.12
User Definition .........................................
.18
System Attributes .......................................
.19
SystemTiming
........................................
..2 1
System Function Codes ..................................
.23
AlarmTypes ..........................................
..2 5
TroubleTypes .........................................
..2 8
ZoneDefinition ........................................
..3 0
KeypadConditions
....................................
..3 3
Partitions.. ...........................................
..3 4
Upload Parameters .....................................
.35
CHAPTER 10: Programming Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Quick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...37
Intermediate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Partitioned..............................................39
Advanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..~...........~...40
CHAPTER 11: System Defaults .; . . . . . . . 1: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .‘:.-.::...! . . . . . . . . . . ii.....41
3.” ’
.
.*
I’
..
.’
,.
r
r?
,
The LEGEND - 100 panel is completely programmable through the LCD keypad. The panel is
shipped from the factory with preprogrammed default characteristics which will suit many LEGEND
installations. These default values are displayed in the section of this manual titled LEGEND - 100
System Defaults.
Installer programming through an LCD keypad can be used to setup the panel during the initial
installation or to modify programmable values at a later date. In addition, the LEGEND-l 00 can be
programmed through the EZ-MATE Programmer (model 7150 using the model 7160 cartridge) or
EZ-MATE PC Based Downloader.
LEGEND-l 00 keypad programming is accomplished through a series of questions presented on
the LCD keypad display. These displays contain easy to understand, simple english language
prompts. The programming questions are described in detail in the LCD Keypad Programming Ques-
tions section of this manual.
The keypad programming sequence has been designed to take into account typical LEGEND in-
stallations. You only have to answer the questions that are applicable to the level of your installa-
tion.
Keypad programming is reserved for installer use only and is secured by the installer code. Func-
tions such as user code modification can be performed through keypad entry without the need to
enter the keypad programming mode.
If your LEGEND installation includes only LED keypads, and you want to perform keypad program-
ming,then an LCD keypad can temporarily be connected to program the unit through the keypad.
Note: Keypad programming can only be performed while the system Is In
a disarmed state.
LEGEND-l 00 KEYPAD PROGRAMMING Page 1
2. PROGRAMMING MODE - LCD KEYPAD
When the LEGEND panel has been placed into programming mobe the keys have a dedicated
meaning. Since, this differs from the normal key definition a programming overlay exists to display
the descriptions during Installer Programming.
Fire Burglary Instruments
Installer Programming
LCD Keypad Overlay
Entry into Programming mode:
CODE l /fnaaNer Code) 1
Where: CODE l is the Code key
followed by l .
[Installer Code] is six digit code
1 is the digit 1.
Exit from Programming Mode:
+ + # (or SHlkT + ABORT)
Press the * and # keys at the same time.
00
0
Next Letter
0
Shlft
0
0
.O
0
Prev. Letter
0
0
Toggle
Abort
0
0
0
Next Question
Previous Questlon
C
Fomard
I
1
Backwards
7693 I- 2373
LCD KEY‘PAD - PROGRAMMING MODE
NEXT QUESTION
This function key processes the information entered on the display and advances to the next
programming display. The next display depends on the programming level and the response made
to the current question. The questions have been organized to skip questions which are not neces-
sary based on previous responses. For example, if a secondary receiver telephone number is not
defined, then the related questions dealing with the secondary number will be skipped. Therefore,
do not be alarmed if the NEXT QUESTION key does not always obtain the next sequential question
number.
PREVIOUS QUESTION
The PREVIOUS QUESTION key will sequence the display backwards to the previous question
of the programming sequence. This key can be used scroll backwards through the questions.
FORWARD
Advances the cursor position forward within the second line of the display. The forward key does
not change information. If the question type a numerical or text then the FORWARD key will ad-
vance the cursor to the left by one position. If the display contains multiple Yes/No questions then
the forward key will move the cursor to the next slot on the display.
BACKWARD
Similar to the forward key except that the cursor will be moved to the previous position.
LEGEND-l 00 KEYPAD PROGRAMMING Page 2
The NEXT LEITER key is used only for text questions. Text questions request entry of charac-
ters. This includes the letters A-Z, numbers O-9, space character as well as the other characters that
.-‘would normally -be seen on a’typewriter or computer keyboard. Entry of text information is ac-
complished through use of the next letter key. The cursor must be positioned to the desired position
and the next letter key will advance the display through the character set one character at a time.
When the desired character has been reached hit the FORWARD key to advance the.cursor to the
next position. When all the desired entries have been completed forthe text field hit the NEXTQUES-
TION key.
In addition to the NEXT LETTER key advancing one character at a time, depression of the SHIFT
key followed by the NEXT LETTER ( 7 ) key will advance through the character sequence more
rapidly. When the desired character has been reached depress the NEXT LETTER (7) key again
to stop the display.
The character sequence includes the, letters A - Z along with the following;
A-Z(I)space!“#$%&‘()*+,-./0123456769:;
= ?@I
Alphabetic characters can be entered as lower case or upper case values.
ERASE FLD
The ERASE FIELD function is performed by depressing,the SHIFT key (labeled,* in normal opera-
tion) followed by the ERASE FIELD key (normally the 6 key). This will blank out the entire field from
the current cursor position to the end of the field and applies only to numerical and text fields only.
Note: After the SHIFT key is depressed, the Ready light will be lit.
PREV LETTER
The PREVIOUS LETTER is similar to the NEXT LETTER key, however scrolls backwards through
the character set for text entry. The character sequence begins with the last letter accessed by the
system.
In addition to the PREVIOUS LETTER key advancing one character at a time, depression of the
SHIFT key followed by the 7 key will advance through the character sequence rapidly. This will make
one complete pass through the character set. When the desired character has been reached depress
the 7 key to stop the display.
TOGGLE
The TOGGLE key is used for YES/NO questions and multiple choice displays. The toggle key
will advance the second line of the display through the available choices for the question. For ex-
ample in a YES/NO question the TOGGLE key will change the answer from YES to NO if the initial
value was YESThe second line of the LCD display shows the current value. The toggle key advan-
ces the display through the available choices for the programming question. After the last available
choice has been reached, the display will return to the first choice.
When the desired choice has been obtained, the NEXT QUESTION key will finalize the entry and
advance to the next display.
LEGEND-100 KEYPAD PROGRAMMING Page 3
3.,, DISPLAY FORMAT
_.
Installer programming of the LEGEND-l 00 is performed through a series of questions appearing
in the two line display area of the LCD keypad.
The display area of the LCD keypad has the following format during Installer Programming;
Where:
NNN
Question number (000-255.)
The programming questions are assigned sequentially and presented in order based, on the
programming level. In addition any programming question can be accessed directly using this se-
quence number. Some of the questions contain multiple displays to define all of the attributes. For
example, there are multiple displays required to define all of the characteristics of a zone.
TTTTlTlTlTllT
Question Text
Up to twelve characters to describe the question being asked. Due to space limitations some
question titles are abbreviated. If the question deals with an area containing multiple offsets such as
zones or users then the display will contain a reference to the particular value being defined (ex-
ample ZNOl for zone #l). For a complete explanation of each programming question consult sec-
tion 9 of this manual.
VVVVVVVVVVVVVVVV Value
Displays the current contents of the question. This information can be viewed or modified. The
questions consist of the following types; Multiple Choice, Yes/No; Numerical, Hexadecimal, or Text.
If the question contains more than sixteen characters then a second display will appear when in-
putting a value greater than sixteen characters. This secondary display contains a left arrow in the
last position of the first line indicating continuation of the first display. This relates primarily to the
telephone numbers which can contain up to 32 digits.
LEGEND-100 KEYPAD PROGRAMMING Page 4
A numerical input display will generally show the valid range of responses for the question. For
example, if a question requires input between 1 and 16 this will generally appear on the LCD dis-
play.
The FORWARD and BACKWARD keys can be used to move the cursor position to edit existing
digits.
Note: Data entry generally requires that the maximum number of digits be entered. For example
an entry of 3 into a two digit field will require entry of 03.
EXAMPLE:
Enter the desired number of attempts (01 i 16) followed by depression of the NEXT QUESTION
key.
HEXADECIMAL
Hexadecimal questions allow input of the digits O-9 and A- F. The values O-9 are entered direct-
ly from the keypad while A-F are input as follows;
VALUE
ENTRY SEQUENCE
A
SHIFT 1
B
SHIFT 2
C
SHIFT 3
D
SHIFT 4
E
SHIFT 5
F
SHIFT 6
For example, entry of an F requires depression of the SHIFT key followed by the 6. NOTE: After
the SHIFT key has been pressed the Ready light will be lit.
EXAMPLE
For example, to enter an account number of A397 type SHIFT 1,3,9,7.
,..
TEXT
The text questions enter the English language descriptions used within the LEGEND panel. Valid
entry consists of the letters A - Z, 0- 9, space, and selected special characters. The letters are
presented as a sequence using the NEXT LETTER and PREVIOUS LETTER keys. These keys will
‘scroll through the character set one letter at a time. When the desired character has been reached,
.use the FORWARD key to advance the cursor position to the next position.
After the entire text field has been entered, the NEXT QUESTION, (or PREVIOUS QUESTION),
key will advance the display and save the text field entered.
Note: The characters sequence will always being with the last letter accessed.
EXAMPLE:
The character sequence contains the following : A - Z, [ ] * _ ‘ a - z ( } - ! @ # % & ’ < > * + - . /
o-9 : : = ?
LEGEND-100 KEYPAD PROGRAMMING Page 5
A numerical input display will generally show the valid range of responses for the question. For
example, if a question requires input between 1 and 16 this will generally appear on the LCD dis-
play.
The FORWARD and BACKWARD keys can be used to move the cursor position to edit existing
digits.
Note: Data entry generally requires that the maximum number of digits be entered. For example
an entry of 3 into a two digit field will require entry of 03.
EXAMPLE:
Enter the desired number of attempts (01 - 16) followed by depression of the NEXT QUESTION
key.
HEXADECIMAL
Hexadecimal questions allow input of the digits O-9 and A- F. The values O-9 are entered direct-
ly from the keypad while A-F are input as follows;
VALUE
ENTRY SEQUENCE
A
SHIFT 1
B
SHIFT 2
C
SHIFT 3
D
SHIFT 4
E
SHIFT 5
F
SHIFT 6
For example, entry of an F requires depression of the SHIFT key followed by the 6. NOTE: After
the SHIFT key has been pressed the Ready light will be lit.
EXAMPLE
For example, to enter an account number of A397 type SHIFT 1,,‘3,9, 7.
TEXT
The text questions enter the English language descriptions used within the LEGEND panel. Valid
entry consists of the letters A - Z, 0- 9, space, and selected special characters. The letters are
presented as a sequence using the NEXT LETTER and PREVIOUS LETTER keys. These keys will
scroll through the character set one letter at a time. When the desired character has been reached,
use the FORWARD key to advance the cursor position to the next position.
After the entire text field has been entered, the NEXT QUESTION, (or PREVIOUS QUESTION),
key will advance the display and save the text field entered.
Note: The characters sequence will always being with the last letter accessed.
EXAMPLE:
i-7
I
k. ’
n
LEGEND-100 KEYPAD PROGRAMMING Page 6
5.’ QUEsTION SELECTION MODES
The keypad programming questions can be obtained either sequentially or directly as follows;
NOTE: In order to use either question selection method you must already
be in the the Installer Keypad Programmlng mode.
SEQUENTIAL METHOD
A fast method to scroll through the sequence of programming questions involves the successive
use of the NEXT QUESTION key. This will advance forward through the the programming questions
in sequential order without changing any of the current values. The questions presented will depend
on the Installer Programming level and the values in previous questions.
FORMAT:
NEXT Q. NEXT Q. NEXT Q. . . . . . . . . . . . . . . .
DIRECT METHOD
Using the direct method any specific programming question can be obtained through the ques-
tion sequence number. This method provides instant access to any LEGEND-100 programming
question through the three digit sequence number. A master listing containing all the programming
questions can be found in the Advanced Programming section of this manual.
FORMAT:
SHIFT NEXT QUESTION NNN
where:
SHIFT NEXT QUESTION is the depression of the SHIFT key followed by NEXT QUESTION
function key.
NNN is the three digit sequence number of the question desired.
Note: The LEGEND-100 must already’be in the Programming mode.
After depressing the SHIFT key followed by the NEXT QUESTION key the following display will
appear;
EXAMPLE:
SHIFT
NEXT QUESTION 003
Press the NEXT QUESTION key followed by 0 0 3. This will obtain question number 03 as fol-
lows;
I
I
In this particular example, the primaiy Central Station telephone number question was obtained.
At this point, the contents of this field can be modified or another question can be obtained.
LEGEND-100 KEYPAD PROGRAMMING Page 7
If the question requested belongs to an area that contains multiple offsets then the direct access,
method will first obtain the selection display for that group. Specifically, this applies to the following
groups:
USERS
ALARM TYPES
TROUBLE TYPES
ZONE DEFINITIONS
KEYPAD CONDITIONS
PARTITION KEYPAD DEFINITION
For example, if requesting the Zone CS Code question (number 113) the Zone selection ques-
tion (111) will first appear. After entry of the desired zone, the first question will appear for that zone.
The next question to apperar also depends on the programming level selected.( See list of program-
ming questions in section 10 of this manual).
LEGEND-100 KEYPAD PROGRAMMING Page 8
6. PROGRAMMING QUESTIONS OVERVIEW
The LCD keypad programming questions have been organized into the following functional
categories;
CENTRAL STATION COMMUNICATIONS
[Quest Ions OOl-0231
This area defines the telephone numbers and dialing options for the LEGEND panel to communi-
cate with a Central Station and the remote programming devices.
USER DEFINITION
[Questlons 024-0281
Defines the characteristics of the users maintained within the panel. This includes the authoriza-
tion levels, CS reporting codes and partitlon assignment.
SYSTEM ATTRIBUTES
[Questions 029-0451
Defines the values which are common to all zones and partitions within the LEGEND panel.
SYSTEM TIMING
[Questions 048.0811
Contains the various programmable timing features (delays and time-outs).
SYSTEM FUNCTION CODES
[Questlons 062-O&?]
System function codes spitclfy the codes transmitted to the Central Station for various conditions.
ALARM TYPES
[Questlons 0850991
Alarm types are used to define the reporting codes and characteristics for different alarm condi-
tions. When setting up a zone an alarm type will be necessary. The system contains up to sixteen
alarm types.
TROUBLE TYPES
[Questlons 109-l lo]
Trouble types are used to define the reporting codes and characteristics for different trouble con-
ditions. When setting up a zone a trouble type will be requested. The system contains up to eight
trouble types.
ZONE DEFINITION
[Questlons 11%137
The LEGEND-l 00 panel can contain up to sixteen hardwired zones. The zones are fully program-
mable and the zone definitions are used to customize the zones to suit your needs.
KEYPAD CONDITIONS
[Quest Ions 136-1421
In addition to the hardwired zones, conditions can be activated through the keypad for situations
such as FIRE, PANIC, MEDICAL, DURESS. This section asks the questions to tailor these condl-
tions to your installation.
PARTITION ASSIGNMENT
[Questlons 143-1451
The LEGEND-l 00 panel can be configured to look like multiple systems to the Central Stations.
In this section defines the keypads that are assigned to each partition.
AUTO-UPLOAD PARAMETERS
[Questlons 146-l 561
One feature of the LEGEND-100 is the capability to transmit a log of system activity to a remote
serial printer. These questions define the frequency of this transmission (daily, weekly, monthly)
along with text to identify each account.
kEGEND- 00 KEYPAD PROGRAMMING Page 9
7. PROGRAMMING LEVELS
, .’
Programming the LEGEND-l 00 through the LCD keypad has been simplified through the use of
installer Programming Levels. The purpose of the programming levels is to ask only the program-
ming questions applicable to the installation. Any questions that are skipped will remain at the
preprogrammed FBI default values.
When entering keypad programming, the first question ( #OOO) requests the programming level.
Based on programming level selected the appropriate questions will be asked. The questions which
are asked for each of the programming levels are shown in section 10 of this manual.
The Programming level question is as follows;
The following Programming Levels exist within the LEGEND-loo;
QUICK
The quick programming level relies mainly on the FBI default values. The installation is intended
as a non partitioned system using the default reporting codes and timing attributes. The zone types
will adhere to the types as described in the System Defaults.
Using the quick mode, it is only necessary to answer some of the communications questions.
INTERMEDIATE
The intermediate level is similar to the quick mode except the installer has additional flexibility in
programming reporting codes, timing options and some of the zone characteristics. This program-
ming level will probably be sufficient for most residential single partitioned installations.
PARTITIONED
Similarto the Intermediate level except that the panel is partitioned. The zones, users and keypads
will be assignable to partitions and account numbers can be programmed for each partition.
ADVANCED
In the advanced level all of the programming questions will be’asked. This level would be for the
‘installation requiring control over more of the advanced features of the LEGEND-loo.
NOTE: if questions are accessed directly, thi? will still adhere to the
programming level selected. For example, if the QUICK mode is selected,
then a request for a programmin’g question contained in advanced mode
will skinned.
r^\
/ ’
‘1 I’
LEGEND-100 KEYPAD PROGRAMMING Page-10
8. SAMPLE LCQ’KEYPAD PROG. SESSl@l
1. ENTER THE KEYPAD PROGRAMMING MODE:
CODE + * [Installer Code] 1
where;
CODE CODE key on keypad
‘* Asterisk key (also labeled SHFl’)
[Installer Code] Six Digit installer code required to gain access to installer only func-
tions such as keypad programming.
1 Entry of 1 from keypad
Place the Programming
overlay over the keypad to observe the purpose of the keys during
keypad programming.
2= SeLECT PROGRAMMING LEVEL
The following display will appear to select the Installer Programming Level;
Use the TOGGLE key to scroll through the following available choices:
QUICK
Simple eight zone. non partitioned LEGEND installation. The questions
presented include some of the CS Communications
questions and User definition. Consult
the system defaults to determine whether this mode suits your installation.
INTERMEDIATE Similar to the QUICK programming level except that certain report-
ing codes, timing options and zone characteristics
arc programmable.
PARTITIONED Identical to the INTERMEDIATE level except that the system is being
setup in a partitioned configuration and the zones, users and keypads are assignable
to the
partitions.
ADVANCED
ln the ADVANCED mode, all programming questions will be presented.
When the desired choice has been selected press the NEXT QUFSTION key to proceed.
3- PROGRAMMING SEQUENCE
The programming questions will be presented
based on the installer programming level
selected. See the LCD Keypad Programming section of this manual for an explanation of
each question and the Master List of Questions for the level associated
with each question.
4- EXIT FROM PROGRAMMING SESSION
After performing the desired programming to the panel exit from the programming ses-
sion as follows;
SHIFT + ABORT (Also known as the l and # keys)
Press the SHIFI and ABORT keys at the same time and the LEGEND-100 panel will
return to the normal disarmed state.
LEGEND-100 KEYPAD PROGRAMMING Pape 11
9. LCD KEYPAD PROGRAMMING QUESTl6NS
This section describes all of the programming
displays
that can appear within the Installer
Programming sequence of the LEGEND- 100 panel.
Based on the programming level selected, the
appropriate questions will be presented.
Note: The sample displays in this section show the
format of the keypad programming questions. The
values that are displayed are meant to demonstrate the
type of input for each question rather than the default
values. The factory default values for the LEGEND-100
programming,guestions are shown in chapter 11 of this
manual.
. .
NOTE: The programming questions displayed in this
section of the manual relates to REVISION 3.2 of the
Legend-100 control panel. The revision number can be
seen on the LCD keypad upon initial system power-up
and on a label located on the panel wiring diagram.
9.1. PROGRAMMING LEVEL
The Programming level determines the questions
which will be displayed during the keypad Programming
session. Depression of the TOGGLE key will scroll
through the following Programming level choices;
QUICK
INTERMEDIATE
PARTITIONED
ADVANCED
Once the desired programming level has been
reached press the NEXT QUESTION key. Each of these
choices is des.cribed in the the Programming Levels
section of this manual. The questions that are presented
with each programming level are listed in section 10 of
this manual.
9.2. CS COMMUNICATIONS
The Central Station Communications section
defines the telephone numbers and dialing options for
the LEGEND-l 00 panel to communicate with a Central
Station receiver and the remote programming devices.
CALLBACK TELEPHONE NUMBER
IOOIC*LLII*CKI
The LEGEND-100 can be programmed and
operated remotely from either the Alarm Company
location. This two way capability includes remote
programming (uploading, downloading) and commands
(ARM/DISARM, BYPASS, DEVICE ACTIVATION,
SYSTEM STATUS).
All remote activations are performed over a
dedicated telephone line at the Alarm Company known
as the Callback Number. This number should be
common to all LEGEND-100 panels installed or
maintained by the same company.
Enter the Callback Number which will represent the
fixed telephone number dedicated to your EZ-MATE PC
Downloader or EZ- MATE Programmer within your
alarm company.
The Callback number is a security feature which
prevents unauthorized stations, from accessing your
control panels. If the.Callback number is lefl blank then
the panel will not call back the Alarm Company location
during remote communications, allowing use of the
EZ-Mate Programmer from any remote location.
NOTE: The Callback telephone number should not
be confused with the Central Station Receiver numbers.
In addition, if the device will never be operated remotely,
then the Callback Number should be left blank.
LEGEND-100 KEYPAD PROGRAMMING Page-12
All telephone numbers should be entered through
the LCD keypad programming sequence as follows;
The phone number should be entered with any area
codes or access characters needed to dial the
telephone number from the control panel location. The
valid digits for all phone numbers are 0- 9, A’& or C.
The phone digits are entered as follows;
o-9
Actual telephone # digits
B (Shlft2)
#
C (Shift 3)
3 Second delay
Do not enter blanks or separators between the
digits as this will be interpreted as the end of the
telephone number. A totally blank phone number
indicates that the phone number does not exist. For
example, a blank CS#2 Phone number indicates that
the panel does not communicate with the secondary
Central Station.
To blank out an existing telephone number move
the cursor to the first position and depress the SHIFT
key followed by the 8 key. To advance the next
programming question press the NEXT QUESTION
key.
Telephone numbers within the LEGEND’1 00 panel
can contain up to 32 digits. Since the LCD display
contains only sixteen characters a secondary display
will automatically appear if a phone number greater than
18 characters is entered. This secondary display will be
denoted with a small left arrow in the last position of the
first line.
DUMP TELEPHONE NUMBER
The LEGEND-100 stores the last 128 events that
have occurred. This system log information can be
viewed by an Installer through an LCD keypad, read by
the EZ-MATE Programmer or Downloader, or dumped
automatically to a remote printer. The remote printer can
be located at the Alarm Company, Central Station or
other remote location such as a guard shack or
corporate security off ice.
The DUMP telephone number defines the
telephone number of this remote printer and modem
and can vary from account to account.
If the panel should not transmit system log
information then leave this question blank. The DUMP
telephone number can contain up to 32digtts. Additional
information for the Auto Dump function is defined in
questions 145156. The Auto Dump feature requires a
modem and serial printer at the remote location.
See the Callback Number for an explanation of
telephone number entry.
PRIMARY CENTRAL STATION RECEIVER
The LEGEND-100 can transmft digital alarm
signals to two separate Central Station numbers. Enter
the complete telephone number of the primary Central
Station receiver line. The telephone number should be
entered with the correct area code or access control
digits necessary to dial the Central Station receiver from
the panel location.-
The primary CS phone number can contain up to
32 digits. If the panel does not communicate with the
primary Central Station or the panel is being used in a
local only application then leave this question blank.
To erase an entire existing telephone number,
position the cursor at the first digit and depress the
SHIFT key followed by the 8 key.
See the Callback Number for a full explanation of
telephone number entry.
CS#l PULSES PER SECOND
plYOt~sA~l
1
This question selects the speed for transmissions
to CS#l . The valid options are;
1OPPS 1400
10 Pulses Per Second wfth a
1400 Hz handshake
1 OPPS 2300
10 Pulses Per Second with a
2300 Hz handshake
2OPPS 1400
20 Pulses Per Second wfth a
1400 Hz handshake
20PPS 2300
20 Pulses Per Second with a.
2300 Hz handshake
4OPPS 1400
40 Pulses Per Second with a
1400 Hz handshake
40PPS 2300
40 Pulses Per Second with a
2300 Hz handshake
BFSK
BFSK Format
FBI
FBI Format (4x3~1)
Note: This question will be skipped if signals are not
transmitted to CS#l (question 003).
CS#l PARITY SELECTION
LEGEND-l 00 KEYPAD PROGRAMMING Page-l 3
Enter the desired parity setting for CS#i
transmissions. Parity is an error detection scheme
which is used in certain CS transmission formats. If you
are unsure about the parity setting for your receiver
please contact your Central Station manager.
Note: This question will be skipped if signals are not
transmitted to CS#l (question 003).
CS#l MESSAGE FORMAT
Specifies the message format transmitted to CS#l .
The message format indicates the method used by the
control panel to transmit the account number and
information to the Central Station. Since the terminology
used by different manufacturers varies, please refer to
the examples below+to select the desired format. the
options are as follows;
STANDARD - All transmissions contain account
numbers of three or four digits followed by a single digit
alarm code. For example,
1236
-’
or
2794 7
This format may also be known as 3x1,4x1 ‘or non
extended.
EXTENDED -All transmissions in extended format.
In this fomiat the first round contains an expansion digit
which appears as the account number in the second
round. This format is sometimes also known as
expanded or universal format. For example;
123.3
333 6
5483 1
11114
Extended format messages may contain either
three or four digit account numbers.
PARTIAL EXT. Alarms cot&ions are transmitted
as single line messages, however non alarm conditions
such as restoresOpens, Closes, Troubles,. etc. are
extended messages. Example;
ALARM
1233
RESTORE
123E
EEE 3
4x2 - All messages are sent with a two digit
condition code in a single transmission. The account
n
number transmitted depends on the numberof digits
/
j
defined in the account number field. Example;
‘i
5482 31
Note: The ‘format entered in this question will be
ignored if the answer to question #004 is either BFSK
or FBI.
SECONDARY CENTRAL STATION RECEIVER
lz!3
Enter the telephone number of the secondary
Central Station receiver line. If the panel only
communicates with the primary receiver, leave this field
blank. The secondary phone number can contain’up to
32 digits.
To erase an entire existing telephone number,
position the cursor at the first digit and depress the
SHIFT key followed by the 8 key.
See the Callback Number description for
explanation of telephone entries.
CS#2 PULSES PER SECOND
pi!Ezq
This question selects the desired speed for signals
transmitted to CS#2. Select from the following options;
f-
10 PPS 1400
10 Pulses Per Second with a
.
’
1400Hz handshake.
10 PPS 2300
10 Pulses Per.Second wfth a
2300 Hz handshake
20 PPS 1400
20 Pulses Per Second with a
1400. Hz handshake
20 PPS 2300
20. Pulses Per Second with a
2300 Hz handshake
40 PPS 1400
40 Pulses Per Second wfth a
1400 Hz handshake
40 PPS 2300
40 Pulses Per Second with a
2300 Hz handshake
BFSK
BFSK Format
FBI
FBI Format (4x3~1).
Note: This question will be skipped if messages are
not transmitted to CS#2 (question 007).
CS#2 PARITY SELECTION
pEEEy
Enter whether parity should be sent on
transmissions to CS#2. Parity is an error detection
scheme which is used in certain CS transmission
c-=-
LEGEND-l 00 KEYPAD PROGRAMMING Page-l 4
formats. If you are unsure about the parity setting please
contact your Central Station manager.
Note: This question will be skipped if there is no
transmission to CS#2 (question 007).
CS#2 MESSAGE FORMAT
Specifies the message format transmitted to CS#l .
The message format indicates the method used by the
control panel to transmit the account number and
information to the Central Station. Since the terminology
used by different manufacturers varies, please refer to
the examples below to select the desired format. the
options are as follows;
STANDARD - All transmissions contain account
numbers of three or four digits followed by a single digit,
alarm code. For example,
1236
or
2794 7
This format may also’be known as 3x1,4x1 or non
-extended.
EXTENDED -All transmissions in extended format.
In this format the first round contains an expansion digit
,
0
which appears as the account number in the second
round. This format is sometimes also known as
expanded or universal format. For example;
1233
333 6
5483 1
11114
Extended format messages may contain either
three or four digit account numbers.
PARTIAL EXT. Alarms conditions are transmitted
as single line messages, however non alarm conditions
such as restores,CIpens, Closes, Troubles, etc. are
extended messages. Example;
ALARM
1233
RESTORE
123E:
EEE 3
4x2 - All messages are sent with a two digit
condition code in a single transmission. The account
number transmitted depends on the number of digits
defined in the account number field. Example;
5482 31.
Note: The format entered in this question will be
ignored if the answer to question #004 is either BFSK
or FBI.
NUMBER OF PARTITIONS
The LEGEND-100 can be set up to look like multiple
control
panels to the Central
Station.
These
independent subdivisions are known as partltlons.
Enter the number of partitions for this installation. If the
system is non partitioned then the number of partitions
should be 1. The zones, keypads and users associated
with each partition will be defined in later questions.
Default value = 1.
Partitioning can be used for applications such as
townhouses, apartment buildings, shopping centers,
industrial complexes or office suites where separate,
independent areas are needed. Each partition can
contain any number of keypads and zones. In addition
each user code can be granted or denied access to any
of the partitions.
PRIMARY CS ACCOUNT NUMBER
:
Enter the account number to be reported to CS#l
(Question #3). The account number questions (12 and
13) will be repeated for the number .of partitions
specified in question number 11. The portion of the
display labeled P# indicates the partition number being
entered.
The account numbers can be up to four digits. If a
three digit account number is desired then enter XXXb,
where XXX is the desired three digit account number
followed by a blank (depression of the SHIFT. key
followed by the 8).
If the partition should not report to CS#l then enter
a blank account number. To erase an existing account
number position the cursor on the first digit and depress
the SHIFT key followed by the 8 key.
Valid entries, for the account number question
includes the digits O-9 or B-E (SHIFT 2 - SHIFT 6). Enter
the account number exactly the way it would be seen at
the receiver. Consult your Central Station Manager to
determine the valid digits accepted by your receiver.
LEGEND-100 KEYPAD PROGRAMMING Page-15
SECONDARY CS ACCOUNT NUMBER
pizEq
Enter the account number to be reported to CS#2
(Question #8). The account number questions (12 and
13) will be repeated for the number of partitions entered
in question number 11. The portion of the display
labeled P# indicates the partition number being entered.
The account numbers can be up to four digits. If a’
three digit account number is desired then enter XXXb,
where XXX is the desired three digit account number
followed by a blank (depression of the SHIFT key
followed by the 8).
If the partition should not report to CS#2 then enter
a blank account number. To erase an existing account
number position the cursor on the first digit and depress
the SHIFT key followed by the 8 key.
Valid entries for the account number question
includes the digits 0-Sor A-E. Enter the account number
exactly as it would be seen at the receiver. Consult your
Central Station manager to determine the valid digits for
your receiver.
PANEL INSTALLER CODE
71,
The LEGEND-l 00 contains a series of functions
which can only be performed by an authorized installer.
These functions include keypad programming, walk
test, time setup, and system log view.
In order to perform any of these installer reserved’
functions entry of this six digit installer code will be
necessary. Each alarm company should select a six
digit code in order, to secure their panels from other
installers. The code should probably be kept uniform for
each Alarm company. The factory default value for the
installer code is 123456.
NOTE: Special care should be made whenever
changing the installer code value since subsequent
keypad programming sessions will require the code
entered.
TO&H TONE DIALING ENABLE
pGxErI
i
Indicates whether touch tone dialing should be
enabled for the panel. If. touch tone dialing is not
selected then pulse dialing will be performed. Default
value = NO
This question will be skipped if all of the telephone
numbers have been defined as blanks..
CENTRAL STATION DIALER ENABLE
This question indicates whether the communicator
section wiil be active for the panel. If the system is being
operated as a local alarm only or the dialer operation
should be suspended enter NO. Default F YES.
REMOTE OPERATION
pGzy;,,,
Indicates whether remote.actions of any kind witI
p
be permitted on this panel. This includes uploads,
i
downloads,
arms/disarms,
bypasses and status
checks. These commands can be performed through an
EZ-MATE, Programmer or EZ-MATE PC Based
Downloader.
Questions 18 and 19 will specify which remote
actions will be permitted.
REMOTi.ARM/DISARM ENABLE
Indicates whether this panel can be armed’and
disarmed remotely through an EZ-MATE Programmer
or EZ-MATE PC Based Downloader. This question
provides an additional layer of security for remote
operations.
REMOTE BYPASS ENABLE
Indicates whether this panel can have individual
zones bypassed or unbypassed remotely through an
p
\
LEGEND-100 KEYPAD PROGRAMMING Page-16
EZ-MATE Programmer or EZ-MATE PC Based
Downloader. Thk question will be skipped if the answer
to the Remote Operations question 17 is NO.
NUMBER OF AtiEMPTS
I020 # ATTEMPTS
1
I_
(01-16)
I
Indicates thenumberof attempts made by the dialer
to reach the Central Station receiver. Transmission will
repeat up until the maximum number of attempts if a
transmission is unsuccessful.
If there are two Central Station telephone numbers
defined and the type of signal should be sent to both
receivers, then transmission will alternate between the
two numbers if either line is busy.
Default value = 8, 16 means 16 attempts.
RING COUNT
Whenever the Alarm Company attempts to
communicate remotely with the LEGEND-100 it will dial
the telephone number attached to the control panel.
This question determines
how many rings are
necessary for this LEGEND-100 panel to pickup.
The number of rings should be selected not to
interfere with normal operation of the protected premise.
For example, if the LEGEND-100 is connected to the
existing telephone line of the location a value of one ring
for pickup would probably be undesirable since the
panel would pickup and seize the telephone line every
time the phone rang.
If an answering machine is present at the control
panel site, then the number of rings should be set
greater than the number of rings for the answering
machine to pickup.
Default value e-10.
EXTENDED ANTIJAM TIME
pgiElq
The LEGEND-100 contains an anti-jam feature
before it performs any communicator dialing. The
antijam feature will disconnect the internal telephone
line and perform a hang-up on any external connection.
The standard hang-up t/me is b seconds while the
extended option will hang up for 30 seconds prior to
dialing.
The antijam time represents the amount of time that
the panel will wait between the time that the dialer has
seized the line to the time that the dialing begins.
Default = NO.
EXTENDED ACKNOWLEDGMENT
023 120 SEC ACK
NO
I
Indicates whether the panel should waft up to 120
seconds for an acknowledgment from the .Central
Station receiver, otherwise the panel will wait 30
seconds. Default = NO.
LEGEND-100 KEYPAD PROGRAMMING Page-17
I
.’ 9.3. USER DEFINITION
This section of the Installer keypad programming is
used to setup the authorization levels and user partition
‘assignments within the panel. The definition of the
actual user codes is not performed within the Installer
Keypad Programming sequence. User definition. or
modification can be performed through normal keypad
entry by the installer or authorized end user.
SELECT USER NUMBER
‘.
pEi%q
This display selects the user number to be
maintained. The LEGEND-100 can contain up to
sixteen different users. Entry of 00 will skip the USER
questions and advance to the next group of questions.
USER AUTHORIZATION LEVEL
yl
Authorization level of this user within the panel. The
values range from 1 (highest) to 4 (lowest) as defined
below;
LEVEL 1
Arm, Disarm, Bypass, Program
Users
LEVEL 2
Arm, Disarm, Bypass
LEVEL 3
Arm, Disarm
LEVEL 4
Arm (Temporary User)
Note: User#l is always a level 1 user.
USER CS OPEN/CLOSE ID
pGEq
This.indicates the digit which will be transmitted to
the Central Station when this user opens or closes the
premise. The default value for each users CS,code will
be the user number. If Open/Close signals are not
transmitted then this value will be ignored, ‘or if STAN
format has been selected which only transmits the
opening or closing code (questions 006,010) .
USER PARTITION ASSIGNMENT
.-I
’
cc
This question defines the partition assignment for
this user. Users can be defined for multiple partitions
which means that their user access codes will be
accepted at the keypads associated with more than one
partition. If the system is being operated as a single
partition then all active users should be defined to
partition number 1. If a user is active in more than one
partition then the account number transmitted will
depend on the partition where the signal was initiated.
The FORWARD and BACKWARD keys are used
to move the cursor to the desired position and the
TOGGLE key allows YES/NO selection for the
partition.For example, the first position represents
partition#l , the second position is partition #2 etc.
This question will be skipped if the installation is
non-partitioned.
USER MASTER PARTITION
028USMAST#xx
1 -U-8)
I
The LEGEND-l 00 panel contains the capability to
p‘
define, modify and delete users from the keypad. Users
can modify other users only if they have been defined
as a level 1 user . As an additional precaution against
users performing modifications
across partition
boundaries each level 1 user will contain a mast,er
partition value. This indicates the partition where they
are permitted to modify users.
”
This question will be skipped if the system is not
partitioned, or the user is not defined as a level 1 user.
LEGEND-100 KEYPAD PROGRAMMING Page-18
9.4. SYStiM AITRIBUIES
The System Attributes defines the parameters
which are common to all zones and partitions within the
control panel.
OPEN/CLOSE CS REPORTING TYPE
vr”
Specifies to which Central Station opening and
closing signals are transmitted. The options are;
CS#l ONLY
Primary rec. only
CS#2 ONLY
Secondary rec. only
CS#l & CS#2
Both receivers always
CS#l THEN CS#2
CS#l backed up by CS#2
NONE
No O/C transmissions
TEST SIGNAL REPORTING TYPE
~“gIT~IT~~~cs1
1 \
Specifies to which Central Station the periodic
system test signals are transmitted. The options are;
CS#l ONLY
Primary rec. only
CS#2 ONLY
Secondary rec. only
m
CS#l & CS#2
Both receivers always
CS#l THEN CS#2
CS#l backed up by CS#2
NONE
No Test transmissions
-
SYSTEM TEST INTERVAL
Indicates the frequency of automatic system test
reports. Test reports can be transmitted to the Central
Station on a daily (every 12 or 24 hours) or on a weekly
basis. System Test signals will be transmitted only if
specified in question 030. The test code transmitted is
entered in the System Test question (#065). The hour
of the day for transmission of system test is entered in
question 065.
This question will toggle between the following
options;
12 HOUR
24 HOUR
SUNDAY
MONDAY
TUESDAY
WEDNESDAY
THURSDAY
FRIDAY
SATURDAY
ENABLE 16 ZONE OPERATION
pzzzzq
The LEGEND-100 panel contains eight zones on
the main control board with an additional eight zone
capability through an expansion board. If the expansion
board is present in the system answer YES to this
question. Default = NO.
NOTE: Only answer YES to the question if the zone
expansion board is present.
BYPASS TRANSMISSION TYPE
VI
Specifies when bypasses are transmitted to the
Central Station. The options are;
BY PASS
Transmit at time of bypass
ARM
Transmit upon system arming
Bypassing can be enabled or disabled by zone.
AUTO UNBYPASS ENABLE
71
Indicates
whether
bypassed
zones will
automatically be unbypassed upon system disarm.
Restores will be generated for the bypassed zones if a
restore code has been defined.
ARMING OUTPUT LEVEL
71
Indicates the desired voltage level on trigger output
for arming status. The system contains one voltage
output located on the trigger connector of the control
panel which represents the current arming state for the
entire panel. If the system contains multiple partitions
then this output will be at the selected level if any of the
partitions are armed. The options are are HIGH and
LOW.
BELL TEST AT ARMING
piJEzE/
Indicates whether a bell test will be performed when
the system is armed. Default = NO. NOTE: The bell
output is assumed to be relay 1.
LEGEND-100 KEYPAD PROGRAMMING Page-19
BELL RINGBACK AT CLOSING
pYYzGq
Indicates whether there will be a bell ringback at
closing. If YES then the bell (relay 1) will pulse several
t/mes indicating a successful closing signal to the
Central Station. If the system is partitioned then this can
occur for each of the partitions.
Default = NO.
SOUNDER RINGBACK
pYE&q
Indicates whether a sounder ringback will occur and
applies to all signals transmitted to the Central Station
This is similar to the bell ringback option described in
the previous question except this involves the keypad
sounder. If the system is partitioned then the sounder
ringback will occur at the keypads defined for the
partition that has closed. Default = No.
FIRE VERIFICATION
1039 FIRE VERIF 1
Indicates whether relay number 2 will act as a fire
(or smoke) verification. If YES then relay #2 must be
dedicated to the fire reset function . Any fire zones that
require verification must be enabled in question 134. If
Fire Verification is not used then relay #2 is available for
other purposes. Default = No.
RESET KEY FUNCTION
VI
Indicates whether the system reset function can be
performed through simultaneous depression of the 3
and 1 keys. This is an alternative to entry of a valid user
code. The RESET function
would be used to
acknowledge system activity such as alarms or troubles
and to exit the alarm memory mode.
If YES then system reset can be performed using
the 3 + 1 keys or a valid user number . If NO then only
a valid user code is accepted.
RESTORES TO FOLLOW LOOP
Indicates whether all restore signals are to follow
the loop or after bell cutoff. If NO then restores occur
after the bell cutoff period. Default = NO.
ACTION ON ABORT
Indicates the action to be taken on an abort. The
options are;
ABORT CODE Transmit the abort code
STOP DIALING Stop the transmission, send
nothing,
NO ABORT
No abort capability
RESTORE
Transmit the restore code
The abort action is system wide and will be used
for all zones within all partitions.
ENABLE KEYPAD COMMANDS
The Legend-100 contains some user initiated
keypad commands for functions such as Quick Arming,
Forced Arming, Time Set etc. These commands can be
n
enabled or disabled using this question.
i
ENABLE KEYPAD DIRECTORY
The Legend-100 has a user initiated keypad
function (LCD keypads only) which can scroll through
the zone descriptions for all zones assigned to the
partition ( # 4 ). This question enables or disables the
keypad directory function.
This option enables an authorized user at one
keypad to access other partitions within the system
through the # 0 command. Users will be able to view the
status of other partitions and perform commands from
thekeypad.
LEGEND-l 00 KEYPAD PROGRAMMING Page-20
9.5. SYSTEM TIMING
The System Timing section allows programming of
the timing options of the LEGEND-100 panel.
BELL DELAY TIME
1046 BEL DEL 15SC 1
I
(00-15)
-.
Amount of time in 15 second increments prior to
activating the bell (relay #l) upon system activity. The
value is specified in steps of 15 seconds from 00 to 14,
with 15 meaning an infinite delay. Example 00 = No
delay 03= 45 second delay.
Each alarm type will specify whether they adhere
to the bell delay, For example, although the normal bell
delay might be 30 seconds there might be certain
emergency, conditions which require no delay.
DIALER DELAY
1047 DIAL DEL 1% 1
.’ 1 -(OO-15)
I
Indicates the amount of time before dialer activation
in 15 second intervals. Similar to the bell delay, an
option exists to override the dialer delay for certain
conditions.
EXIT DELAY
1048 EXIT DL 154
I ,mJ-15)
Specifies the exit delay in 15 second increments.
Theexitdelaycan bedefinedfromo to 14fifteen second
Intervals, with 15 indicating an infinite exit delay.
The exit delay will be used for.zones which have
been defined as exit/entry type zones.
ENTRY DELAY1
049 EN DEL1 15SC
The LEGEND-l 00 contains two separate entry time
periods. This allows different entry times for different
.zones. For example a keypad placed by a garage door
might require more time than a keypad located next to
the front door. Each zone allows selection of either entry
time (see question #127).
Specify entry delay #l In 15 second Increments.
The entry delay can be defined from 0 to 14 fifteen
second intervals, with 15 indicating an infinite exit delay.
ENTRYDELAYP
*m
Specifies entry delay #2 in 15 second increments.
The entry delay can be defined from 0 to 14 fifteen
second intervals, with 15 indicating an infinite exit delay.
When defining individual zones an option exists to
select entry delay 1 or 2.
CS TEST TIME
171
Indicates the time of the day for transmission of the
system test signal. If a test signal has been defined then
the code will be transmitted at the hour speclfled In this
question.
Enter 00 - 23 to indicate the system test hour In
military time. (003 Midnight, 23= 11 PM). An entry of 24
indicates that a system test signal should not be
transmitted. The system test will be transmitted, if
defined, starting at this time every 12 or 24 hours based
on the answer to question #031. The code transmitted
will be defined in question 066.
If the system is partitioned the test signal, if
transmitted, will be sent using the account numbers for
partition number 1.
AC LOSS DELAY
ylIn,*
Indicates the time delay in 15 w
intervals for
transmission of an AC loss signal. AC failure must exist
for the AC loss period before an AC toss signal will be
transmitted.
A value of 00 indicates that AC failure should be
sent immediately, while a value of 15 indicates that AC
loss should never be sent. Defauft value = 2.
.b
LEGEND-100 KEYPAD PROGRAMMING Page-21
.
Indicates whether any of the eight programmable
voltage level output triggers will be activated upon an
exit condition. The position of the Y or N indicates the
trigger number. This trigger will be latched for the
duration of the exit interval. Default = NNNNNNN.
The FORWARD and BACKWARD keys are used
to position the cursor to the desired position while the
TOGGLE key will change the Yes/No status of that
trigger.The first position represents trigger #l, the
second position trigger #2, etc
ENTRANCE TRIGGERS
-1
Indicates whether any of the eight programmable
voltage level output triggers will be activated upon an
entrance condition. The position of the Y or N indicates
the trigger number. This trigger will be latched for the
duration of the entrance interval. Default = NNNNNNN.
The FORWARD and BACKWARD keys are used
to position the cursor to the desired position while the
TOGGLE key will change the Yes/No status of that
trigger. The first position represents trigger #l, the
secong trigger #2, etc..
CUTOFF TIMER #l
055 TIMER1
1MIN
1
(00-15)
-
I
The LEGEND-100 contains three different bell
cutoff times which can be selected for the alarm and
trouble types. Enter the duration of timeout #l in one
minute intervals.
CUTOFF TIMER #2
. .
The LEGEND-100 contains three different bell
cutoff times which can be selected for the alarm and
trouble types. Enter the duration of timeout #2 in one
minute intervals.
NOTE: The cutoff timers are selected in the alarm
and trouble type and relate to whichever relay is used
for that particular alarm or trouble type.
CUTOFF TIMER #3
I
057 TIMER33MIN
~p(oo-15)
I
-
I
The LEGEND-100 contains three different bell
cutoff times which can be selected for the alarm and
trouble types. Enter the duration of timeout #3 in one
minute intervals.
GLOBAL BELL LOCKOUT COUNTER
,pi
Indicates the total number of bell activations from
all zones of the panel that will cause bell lockout. This
counter will be reset with each arming of the system and
will only be incremented by controllable zones that have
been defined with the lockout feature enabled (question
#128). The bell lockout feature merely prevents
repeating activity from triggering the bell. Signals will
continue to be transmitted to the Central Station in
accordance with the zone definition. If signals are to be
suppressed, then the dialer lockout feature should be
considered. Default = lS(None).
If you do not want bell lockout enter 15.
LOCAL BELL LOCKOUT COUNTER
.y1
Indicates the number of bell activations for an
Individual zone that will cause a bell lockout. This
counter will be reset with each arming of the system and
applies only to burglary zones that have been defined
with lockout enabled (see.question #128). Default =
15(None).
If you do not want bell lockout enter 15.
GLOBAL DIALER LOCKOUT LOCKOUT COUNTER
Indicates the number of dialer activations from all
zones of the panel which will cause a dialer lockout. This
counter will be reset with each arming of the system and
applies only to burglary zones that have been defined
with lockout enabled. Dialer lockout does not effect the
bell activation. Default = 15(None).
If you do not want dialer lockout enter 15
LEGEND-100 KEYPAD PROGRAMMING Page-22
LOCAL DIALER LOCKOUT COUNTER
71
Indicates the number of dialer activations from an
individual zone panel which will cause a dialer lockout.
This counterwill be reset with each arming of the system
and applies only to burglary zones that have been
defined with lockout enabled. Default = 15(None).
If you do not want dialer lockout enter 15.
.
9.6. SYSTEM FUNCTION CODES.
‘.
The System Function Codes section defines the
codes that will be transmitted to the Central Station
when various conditions occur. The values A-F can be
entered into any of these questions as follows;
DIGIT
KEYSTROKES
A
SHIFT 1
B
SHIFT 2
C
SHIFT 3
D
SHIFT 4
E
SHIFT 5
F
SHIFT 6
0 .
BYPASS CODE
1
(0-F)
1,
_,
.,
1
’ ‘Indicates the system reporting code for a bypass.
An option exists per zone to determine whether
‘bypasses are reported. Bypasses will be reported to the
Central Station based on the bypass option selected in
question #33.
;
ABORTCODE”
l~;UiYliT6ODE
1,
Indicates the reporting code for an abort. This abort
code will only be transmitted if the ,action on abort
(question #042) specifies Abort.
OPENING &DE
Indicates the reporting code for an opening. If the
system is partitioned then the. account number
transmitted to the Central station will depend on the
partition where the opening occurred. In addition if the
transmission format selected includes the user code
then the user number will be included.
CLOSING CODE
1065 CLOSING CODE 1
1.p (0-F)
P-
Indicates the reporting code for a closing. If the
system is partitioned then the account number
transmitted to the Central station will depend on the
partition where the closing occurred. In addition if the
transmission format selected includes the user code
then the user number will be included.
CS TEST CODE
Indicates the reporting code for a system test. The
type of system test (12 or 24 hour) is defined in question
#031, and the time of test in question # 051.
The system test code represents the entire panel
rather than a specific partition and the account numbers
for partition 1 will be used.
Enter up to two digits for the system test code. If a
single digit reporting format is used then only the first
digit will be used.
AC LOSS CODE
,(,
pgzy
Indicates the reporting code for AC failure. AC loss
will pnly be reported to the Central Station if the loss is
greater than the time period specified in question #052.
AC loss is a system wide condition and will report
using the account numbers for the first partition.
AC RESTORE CODi
Indicates the restore code transmitted upon restore of
.AC.
LEGEND-100 KEYPAD PROGRAMMING Page-23
LOW BATTERY CODE
Reporting code for low battery condition. Low
battery transmission will occur if the battery voltage
drops below 11.5 volts. Low battery conditions will be
reported with the account number for,patlition #l.
LOW BATTERY RESTORE CODE
p$zyGEq
Reporting code for low battery restore condition.
SYSTEM ERROR CODE
-1
Indicates the reporting code for system error.
condition.
SYSTEM ERROR RESTORE CODE
1072SYSERRREST
1
I- (0-F)
I
Indicates the reporting code for system error restore
condition.
DOWNLOADER CODE
The EZ-MATE Programmer and the PC Based
Downloader can transmit database information from the
Alarm Company to the LEGEND-l 00. Upon completion
of a downloading session the panel can transmit a signal
to the Central Station receiver to verify that a
downloading has taken place. This download code will
be sent based on the reporting type specified in the test
type question 030.
The Download code will transmit the account
number for partition #l .
BUZZER ON AC,,LOSS
Indicates whether the buzzer should be activated
upon AC Loss.
BUZZER ON LOW BATTERY
Iy;;UZLOWBATTI
fT
Indicates whether the buzzer should be ,activated \
upon a low battery condition.
BUZZER ON SYSTEM ERROR
ppE&Tiq
Indicates whether the buzzer should be activated
upon a system error condition.
AMBUSH TYPE
prGy
This determines whether a valid user code altered
by + or - one will be interpreted as an ambush cod8.‘lf
NO then user #16 can be interpreted as a systemwide
ambush code based on the information entered in
question 78. DEFAULT = NO.
USER 16 AMBUSH
pzizzq
,-,
This determines whether user #16 will b8 ’
interpreted as a system wide ambush code. An answer
of NO to this question and question 077 means that
there is no ambush code capability within the system. If
both questions 077 and 078 are YES then US8r #16 will
be used as the ambush code.
24 HOUR - AC LOSS
07924 HRACLOS
YES
1
Indicates whether the buzzer should be activated if
the system is armed and an AC loss occurs.
24 HOUR’- LOW BATTERY
08024HRLOBAT
YES
I
Indicates whether the buzzer should be activated if
th8 system is armed and a low battery condition occurs.
24 HOUR - SYSTEM ERROR
r-
/
.
LEGEND-100 KEYPAD PROGRAMMING Page-24
Indicates whether the buzzer should be activated if
the system is armed and a system error condition exists.
TROUBLE TYPE - AC LOSS
082TRTY
ACLOS
1 -(l-4)
1
Indicates the Trouble Type used upon sensing an
AC loss. Default = 1.
NOTE: The Trouble Types are defined in questions
100 through 110 and represents the actions to be taken
when a trouble occurs. This includes the description that
would appear on the LCD display, reporting codes,
trigger outputs etc.
TROUBLE TYPE - LOW BATTERY
71
Indicates the Trouble Type used upon sensing a
low battery. Default = 2.
TROUBLE TYPE - SYSTEM ERROR
084TRTYSYSlSR
1 :u-41
I
Indicates the Trouble Type used upon sensing a
system error. Default = 4.
9.7. ALARM NPES
Alarm types are used to define the reporting codes
and characteristics when a zone goes into an alarm
condition. Each zone definition specifies an alarm type.
The alarm type includes information such as the
description, CS reporting code, reporting type and
trigger outputs. For example the system may contain
more than one BURGLARY alarm type with slight
differences such as a different bell output, or different
CS reporting type.
The LEGEND-100 contains sixteen different alarm
types.
Note: The Alarm Type questions below display the
Alarm Type number as ATxx, where xx will be the actual
alarm type from 01 - 16.
The actual alarm loop characteristics are specified
by zone in questions 118,123,124.
SELECT ALARM TYPE
-1
The alarm type selection display requests the
desired alarm type for maintenance. The valid choices
are 01-16 and an entry of 00 will skip the alarm type
questions and proceed to the Trouble Types.
After completion of the last Alarm type question
(#098), the selection question will reappear and display
the next alarm type value. For example after completion
of alarm type #2 the display will proceed to alarm type
#3.
ALARM TYPE DESCRIPTION
1086DESCR
ATxx
1
The Alarm Type descriptions are used to provide
english language prompts on the face of the LCD
keypad. The descriptions are not transmitted to the
Central Station.
Enter the ten character description to be associated
with this alarm type. If the system contains an LCD
display then this description will appear on the first line
of the display when an alarmcondition has activated.
Examples of alarm type descriptions would include
BURGLARY, FIRE, HOLDUP, LOW TEMP., etc. The
alarm type description should apply to the general
condition rather than the specific zone. The second line
of the LCD display will display the sixteen character
zone description which is defined in question #l 11.
‘ALARM TYPE CS CODE
1087CSCODEATxx)
I- (0-F)
I
Indicates the code transmitted to the Central
Station for this Alarm type. The placement of the code
in the transmission depends on the format selected in
questions 006 and 010.
The LEGEND-100 can transmit to two separate
Central Stations and these two receivers can have
different formats.
LEGEND-100 KEYPAD PROGRAMMING Page-25
The following examples are provided for the
different formats for transmissions of alarm conditions;
STANDARD
Example:
123Z
where Z= Zone CS code (question # 113)
The value entered for the Alarm Type CS code
will not be used.
EXTENDED
123A
AAA Z
where: A = Alarm type CS Code and Z is the CS
code contained in the zone definition (question 113).
NOTE: This format can contain either three or four
digits within the account number.
PARTIAL EXTENDED
123Z
Where: Z = Zone CS code (question #113). The
Alarm Type Cs code is not used for this format.
The partial extended format transmits a single
round signal for alarm conditions and an expanded
message for system conditions such as openings
closings, troubles etc.
NOTE: This format can contain either three or four
digits within the account number.
4x2
1234AZ
where: A= Alarm type CS code and Z is the CS
code contained in the zone definition (question #113).
FBI Superfast Format
1234 AZZA
Where: A = Alarm type CS code and Z is the
decimal equivalent (00-16) of the zone CS code
(question #113).
CS RESTORE
Indicates the restore code to the Central Station for
this alarm type. This code will be transmitted if the
specific zone has the restore option enabled (question
116).
ALARM TYPE CS TRANSMISSION TYPE
VI
Specifies to which Central Station number this
alarm type will be transmitted . The options are;
CS#l ONLY
Primary rec. only
CS#2 ONLY
Secondary rec. only
CS#l & cS#I2
Both receivers always
CS#l OR CS#2
CS#l backed up by CS#2
NONE
No Alarm Transmission
(Local condition)
BELL DELAY
Indicates whether this alarm type should use the
system bell delay. If YES then the delay time will be the
duration indicated in the System Timing question (046).
The type of bell output is selected in question #098
(Relay 1 Select).
ALARM TYPE DIALER DELAY
091 DIALDLATxx
1 YES
Indicates whether this alarm type should wait for
the dialer delay time before communicating with the
Central Station. The dialer delay time is defined in
question #047. If NO dialer delay is selected then this
alarm type will transmit immediately.
ALARM TYPE BUZZER ENABLE
piGq
Indicates whetherthe buzzer (keypad sounder) will
be active for this alarm type. If the condition should be
silent at the keypad then enter NO. If the system is
partitioned then this question will relate to all of the
keypads defined within that partition.
DISPLAY ALARM OPTION
Specifies whether this alarm type should visually
be displayed on the LED or LCD keypads when an alarm
condition exists. This option should be set to NO only if
LEGEND-100 KEYPAD PROGRAMMING Page-26
the condition being defined should not be annunciated
8
at the keypad (example, silent panic).
To the YES option is selected then an alarm will
generate a blinking zone ID light on the LED display or
the appropriate English language display on the LCD
display.
ALARM TYPE BELL CUTOFF SELECT
7^‘“1
Indicates which of the three system bell cutoff
periods applies to this alarm type. The system time-outs
have been entered as questions 055 - 057. and relates
to whichever relays have been selected in questions 98
and 99 for this alarm type.
ALARM TYPE PRIORITY
The LEGEND-100 panel contains a priority
structure in the event that multiple alarms occur at the
same time.
1 =Highest priority, 5=lowest.
ALARM TYPE MOMENTARY TRIGGERS
r*Txx
Indicates which of the voltage level triggers will be
activated for a momentary basis with this Alarm Type.
The triggers are selected by placing a Y in the
appropriate trigger position.
The FORWARD and BACKWARD keys will move
the cursor position to the desired iiigger position, which
indicates the triggere number. The TOGGLE key will
change the Yes/No status of the trigger.
ALARM TYPE LATCHED TRIGGERS
p*Txx
Indicates which of the voltage level triggers will be
activated for a maintained duration with this Alarm Type.
The triggers are selected by placing a Y in the
appropriate trigger position.
The FORWARD and BACKWARD keys will move
the cursor position to the desired trigger position, which
indicates the trigger number. The TOGGLE key will
change the Yes/No status of the trigger.
RELAY 1 (BELL) SELECT
r*T;1
Indicates the action taken for this alarm type on
relay #l . Relay #l typically will be the bell output for the
panel. If a bell is not being used then the relay can be
programmed for anothei application. The options
include;
NONE
PULSED
LATCHED
RELAY 2 SELECT
piT&cGq
Indicates the action taken for this alarm type on
relay #2. If a fire or.smoke reset function is desired then
relay #2 must. be dedicated to this application with a
relay type of NONE. The options include;
NONE
PULSED
LATCH ED
NOTE: If desired both relays can be selected for a
specific alarm type and the timeout selected will be used
for both relays.
After completion of question #099 the system will
return to question 085 with the next sequential alarm
type. After completion of the last alarm type (alarm type
16) the display will advance to question 100.
LEGEND-100 KEYPAD PROGRAMMING Page-27
9.8. TROUBLE TYPES
TROUBLE TYPE DESCRIPTION
The Legend-l 00 system .diff erentiates between
fault (or NOT READY) conditions and troubles. Troubles
are latched conditions and require entry of a valid user
code or the reset function to clear. In addition troubles
can be defined to transmit signals to the Central Station,
and activate relays or triggers much like an alarm
conditions.
The Trouble Type descriptions are used to provide
english language text on the first lineof the LCD keypad.
The descriptions are not transmitted to the Central
Station.
System faults will clear as the condition clears. For
example, if the system is disarmed and a non 24 hour
zone is activated (door or window opened) the keypad
will display the NOT READY condition. For an LED
display this means the zone indicator light solidly on,
and on an LCD display Englishtext showing which zone
is not ready. In either case, the indication will disappear
when the door or window is closed. After all faults are
removed the system is READY.
Enter the ten character description to be associated
with this Trouble Type. If the system contains an LCD
display then this description will appear on the first line
of the display when a trouble condition has activated.
Troubles, on the other hand, are latched conditions
and require entry of a valid user code ‘or the reset
function to clear. In addition troubles can be defined to
transmit signals to the Central Station, and activate
relays ortriggers much like an alarmcondition. Typically
troubles will be used for applications which have a
trouble condition which requires annunciation such as
Fire Trouble, or Foil Break.
Examples of Trouble Type descriptions might
include FIRE TRB, TROUBLE, LOW BATTERY, SYS
ERROR, etc. The Trouble Type description should
apply to the general condition rather than the specific
zone. The second line of a trouble display on an LCD
keypad will contain the sixteen character zone
description entered in question 113.
TROUBLE TYPE CENTRAL STATION CODE
ESCODETRBxI
I- (0-F)
J
Indicates the code transmitted to the Central
Trouble types are used to define the reporting
codes and characteristics
for different trouble
conditions. Each zone definition will define the physical
parameters which constitute the trouble condition as
questions 119, 125 and 126. In addition each zone will
specify a Trouble Type.
Station for this Trouble type. The placement of the code
in the transmission depends on the format selected in
questions 006 and 010.
10
The LEGEND-100 can transmit to two separate
‘-- .s
Central Stations and these two receivers can have
different formats.
The following examples are provided for the
different formats for transmissions of alarm conditions;
Note: The TROUBLE Type questions below display
the TROUBLE Type number as TRBx where x will be
the actual Trouble Type from l-8.
STANDARD
Example:
123T
SELECT TROUBLE TYPE
pgE=q
where T= Trouble Type CS code
This display requests the Trouble Type that you
want to access. The valid choices are l-8 and an entry
of 0 will skip the Trouble Type questions and proceed
to the zone definitions.
The value entered for the zone CS code
(question #113) will not be used.
EXTENDED
123T
llTZ
where: T = Trouble type CS Code and Z is the
CS code contained in the zone definition (question 113).
After completion of the the last question of the
Trouble Type sequence (#i 10) this display will appear
with the next sequential Trouble Type as the Selected
value.
NOTE: This format can contain either three or four
digits within the account number:
PARTIAL EXTENDED
123T
TI-TZ
(-7
7 ._
LEGEND;100 KEYPAD PROGRAMMING Page-28
where: F = Trouble type CS Code and Z is the
CS code contained in the zone,definition (question 113).
NOTE: This format can contain either three or four
digits within the account number. The partial extended
format transmits a single round signal for alarm
conditions and an expanded format for trouble
conditions.
4x2
1234 TZ
where: F= Alarm type CS code and Z is the CS
code contained in the zone definition (question #113).
FBI Superfast Format 4x3x1
1234 TZZT
Where: T = Trouble type CS code and Z is the
decimal equivalent (00-16) of the zone CS code
(question #113).
TROUBLE TYPE CS TRANSMISSION TYPE
-1
Specifies to which Central Station number this
trouble type will be transmitted. The options are;
CS#l ONLY
Primary rec. only
CS#2 ONLY
Secondary rec. only
CS#l & CS#2
Both receivers always
CS#l OR CS#2
CS#l backed up by CS#2
NONE
No Trouble transmissions
TROUBLE TYPE DIALER DELAY
pEEy
indicates whether the dialer delay specified in the
System Timing questions (#047) should be used for this
Trouble Type. If dialer delay option = NO then this
trouble condition will activate the dialer immediately
after the,condition occurred.
”
TROUBLE TYPE BELL DELAY
pi&Exq
Indicates whether the system bell delay (question
#044) should be used for this trouble type. If bell delay
= NO then this trouble condition will immediately
activate the bell (relay #l) in accordance with question
# 109.
TROUBLE TYPE TIMEOUT SELECT
pGpFifq
Indicates which of the three system bell cutoff
timeout periods applies to this Trouble Type for the
relays selected in questions 109 and 110. The system
time-outs have been entered as questions #055 - #057.
TROUBLE TYPE MOMENTARY TRIGGERS
71.
Indicates which of the voltage level triggers will be
activated for a momentary time duration for this Trouble
Type.
The FORWARD and BACKWARD keys will move
the cursor position to the desired trigger position, while
the TOGGLE key will change the Yes/No status of the
trigger.
TROUBLE TYPE LATCHED TRIGGERS
r’““’
Indicates which of the voltage level triggers will be
activated for a maintained duration with this Alarm Type.
The triggers are selected by placing a Y in the
appropriate trigger position.
The FORWARD and BACKWARD keys will move
the cursor position to the desired trigger position, while
the TOGGLE key will change the Yes/No status of the
trigger.
TROUBLE TYPE RELAY 1 (BELL) SELECTION
VI
Indicates the action taken for this Trouble Type on
relay #l . Relay #l is typically the bell output. If a bell is
not. used ,then relay #l can be utilized for another
application. The options include;
NONE
PULSED
LATCH ED
TROUBLE TYPE RELAY.2 SELECT
pIEKE/
Indicates the action taken for this Trouble Type on
relay #2. The options include;
NONE
‘.
PULSED
LATCHED
After completion of this question the Trouble Type
selection question (#lOO) will appear with the next
trouble type as the selected value. The only exception
to this situation is after trouble type 8 , and the display
will advance to question 111.
LEGEND-100 KEYPAD PROGRAMMING Page-29
9.9. ZONE DEFINITION
The Zone definition section describes the attributes
of the hardwired zones connected to the LEGEND-l 00
panel. Each display contains a different zone attribute
question. The zone number being defined is indicated
by the ZNxx notation, in the right hand corner of the first
line of the display.
SELECT ZONE NUMBER
111 SEL ZONE
1 -Ol-16,00 SKIPI,
The zone selection display requests the zone
number to be defined. The hardwired zones are referred
to as 01-16. To skip the zone definition questions
entirely enter 00. Upon completion of the programming
questions for,a particular zone, the selection display will
reappear with the next sequential zone number as the
current value.
if the system has been defined without the zone
expansion module (question #032) then the zone
selection question will only accept input between 1 and
8.
ZONE DESCRIPTION
JI1IDF.SCR.ZNxrI
.Enter the sixteen character description for this
zone. Zone descriptions will appear on the second line
of an LCD keypad when a condition from this zone has
activated. This description will appear for alarms,
troubles , bypasses and NOT READY conditions forthis
zone;‘.
The zone description should probably contain the
location or purpose of the zone.
CS REPORTING CODE
.F[
Indicates the code transmitted to the Central
Station for this zone. The placement of the code in the
transmission depends on the format selected in
questions 006 and 010.
The LEGEND-100 can transmit to two separate
Central Stations and these two receivers can have
different formats.
The :following examples are provided for the
different formats for transmissions of alarm conditions; ,&
STANDAkD
I
Example:
123Z
where Z= Zone CS code
The value entered for the Alarm Type CS code
will not be used.
EXTENDED
123A
AAA Z
where: A = Alarm type CS Code (question #087)
and Z is the zone CS code.
NOTE: This format can contain either three or four
digits within the account number.
PARTIAL EXTENDED
123Z
Where: Z = Zone CS code,. The Alarm Type CS
code is not used for this format.
The partial extended format transmits a single
round signal for alarm conditions and an expanded
message for system conditions such as openings
closings, troubles etc.
NOTE: This format can contain either three or four
digits within the account number.
4x2
f‘
1234 AZ
*-
where: A= Alarm type CS code (question $087)
and Z is the zone CS code.
FBI Superfast Format 4x3x+
1234 AZZA
Where: A = Alarm type CS code (question #087)
and Z is the decimaf equivalent (00-16) of the zone,CS
code , For example a zone code of 12 can be entered
as a C (SHIFT 3) from the keypad.
ZONE BYPASS ENABLE
1114 EN BYP ZNxx 1
YES
I
Indicates whether this zone is bypassable. Zone
bypassing can be performed by an authorized user from
the keypad or from a remote programming device.
Bypasses can be performed whether the system is
armed or disarmed by an authorized user.
ZONE TROUBLE ENABLE
Indicates whether this zone reports trouble
conditions to the CS.
c--J
LEGEND-100 KEYPAD PROGRAMMING Page-30
ZONE CS RESTORE ENABLE
,pzEq
Indicates whether this zone should transmit restore
signals to the Central Station. If restores are transmitted
then they will be handled as follows based on the type
of format (questions 6 and 10);
STANDARD
Example:
123R
where R- Restore code defined for the alarm
type of this zone (question #088)
The value. entered for the Zone CS code
(quest/on #113) will not be used.
EXTENDED
123R
‘RRR Z
where: R = Restore Code (question #088) and
Z is the zone CS code( question #113).
NOTE: This format can contain either three or four
digits within the account number.
PARTIAL EXTENDED
123R
RRRZ
Where: R = Restore Code (question #088 and Z =
Zone CS code (question #113).
The partial extended format transmits a single
round signal for alarm conditions and an expanded
message for system conditions such as openings
closings; troubles etc.
’
NOTE: This format cancontain either three or four
digiF2within the account number.
1234RZ
.-.
where: R = Restore. code (question #088) and Z
is the zone CS code (question #113).
FBI Superfqst Format,4x3xl
1234 AZZR
Where: A T Alarm typeCS code (question #087) for
this zone;
ZZ = the decimal equivalent (00-16) of the zone CS
wd,e. For example a zone code of 12 can be entered
as a C (SHIFT 3) from the keypad.
R = Restore code (question #088).
This format identifies a restore by the zone number
and type of alarm.
PARTITION SELECTION
ill7
PARTIT. ZNxx 1
I
(l-8)
I
r
1
Indicates the &tition that the.zone belongs. Each
zone can ,be assigned to only one partition. If the panel
has been setup as a single ‘partition then all zones
should be assigned to partition number 1. This question
will be skipped if the system contains only one partition,
as defined.in question #ll.
ZONE 24 HOUR ALARM
I’al
.
Indicates whether the alarm portion of this zone
should be active 24 hours a day regardless of the arming
status of the panel.
ZONE 24 HOUR TROUBLE
py
Indicates whether the trouble portion of this zone
should be active 24 hours a day regardless of the arming
status of the panel.
ZONE ALARM TYPE
I120 AL TYPE ZNxx 1
1 - (1-16)
I
Specifies the Alarm Type for this zone. The Alarm
Type defines the conditionsthat should occur when this
zone goes into alarm. The alarm types are described as
questions 85 - 99.
ZONE TROUBLE TYPE
VI.
Specifies the Trouble Type for this zone. The
Trouble Type defines the conditions that should occur
if this zone goes into trouble. If the zone does not have
a trouble condition as specified in questions 125 - 126
then the value placed in this field will be ignored.
LEGEND-100KEYPAD PROGRAMMING Page-31
Indicates the type of zone as follows;
PERIMETER
EXIT/ENTRY
INT. EE FOLLOWER
INTERIOR
NOTE: Fire zones should be defined as perimeter
zones.
ZONE ALARM ON OPEN
pp=Gq
Indicates whether this zone activates an alarm
condition on an open circuit.
ZONE ALARM’ON SHORT
pE/EG-’
Indicates whether this zone activates an alarm
condition on a short circuit.
ZONE TROUBLE ON OPEN
.vO”N
Indicates whether this zone activates a trouble
condition on an open circuit.
ZONE TROUBLE ON SHORT
peJq
Indicates whether this zone activates a trouble
condition on a short circuit.
ZONE ENTRY DELAY
v1
Specifies which of the system entry delay times
should be used for this zone. The TOGGLE key will
switch between the two values. The duration of the
delays are defined in questions 49-50.
NOTE: This question is only used if the zone type
is an Exit/Entry or Interior EE follower.
ZONE LOCKOUT ENABLE
.,I
pqzq
Indicates whether this zone participates in either
bell or dialer lockout. If YES then the various lockout
information defined.in questions 58 - 81 will be used.
e-7
;
’
L. ’
CS BYPASS
129 CS RYP ZNxx
INO
Indicates whether this zone will transmit a bypass
code to the Central Station.
.J
ZONE BUZZER ON TROUBLE
piGCq
Indicates whether the keypad buzzer (sounder) will
be active upon a trouble condition. If YES the trouble
buzzer will be activated at all keypads within the partition
where this zone has been defined.
In order to silence the trouble buzzer it is necessary ,--.,
to enter a valid user code or perform the RESET ?i,_ ’
condition.
ZONECHIME ENABLE
--
pjzy
.
Specifies whether this zone should activate the
chime feature. If the chime mode is enabled then this
particular zone will activate the chime audible signal at
the keypad every time the zone is faulted. This will occur
only when the system is disarmed.
1
ZONE 750MS RESPONSE
132 EN 750M ZNxx
YES
I
Indicates whether this zone has 750 millisecond
response. If not enabled, the noimal zone response is
approximately 250 milliseconds.
P .- ’
LEGEND-100 KEYPAD PROGRAMMING Page-32
ZONE KEYSWITCH ENABLE
Specifies whether this zone will act as a keyswitch.
If YES, then this zone can arm and disarm the partition.
The code transmitted to the Central Station upon
activation will be the opening and closing codes
depending on the condition. If the format selected
includes a user number then a value of 1 will be
transmitted.
ZONE VERIFICATION ENABLE
Indicates whether this zone requires verification.
This would typically be used for a fire zone. If YES, then
this zone must be assigned to partition number 1. This
feature requires that the FIRE RESET function be
enabled (question 039). When the zone activates, the
smoke power will be interrupted and if the fire condition
still exists after power reset, an alarm will be generated.
ZONE SILENCE AFTER RESTORE
Indicates whether this zone will be silenced only
receipt of a restore signal. Typically the sounder
ill be silenced upon entry of the user code. If this option
is selected then the condition must be restored before
the bell will be silenced. This option miaht be,selectad
for a fire zone.
.--
;
--+.
:
ZONE PULSE COUNT TIME
The zone pulse count feature can be configured to
require that this individual zone undergo a certain
number of activations (debounces) within a defined time
period before an alarm condition is tripped. Enter the
time in minutes. A value of 00 indicates that the feature
is disabled for this zone. Default,value = 00.
ZONE PULSE COUNT NUMBER
Enter the number of transitions or pulses that are
required for this zone within the time period defined
above to activate an alarm condition. A value of 00
indicates that the each transition triggers an alarm
condition. Default value = 00.
9.10. KEYPADCONDfllONS
In addition to the sixteen hardwired zones there
are four conditions which can be user activated directly
from the keypad. These conditions can duplicate
functions which already exist as hardwired zones.
The keypad conditions can be initiated as follows;
-
l K+yAD-
1
2
l +l
3
.3+#
4
DURESS SIGNAL
Note: The Duress condition can be initiated either
through entry of a valid user code with the last digit
altered by one (plus or minus). For example, a valid user
with a code of 1234 can initiate a duress condition with
1233 or 1235. Alternately, the duress code can be
dedicated as user number 16. The duress code options
are programmed as questions 077 and 078. The duress
condition will perform the normal disarming procedure
and react with the characteristics specified for keypad
condition 4.
If any of the keypad conditions are defined then they
will be active at all keypads and partitions throughout
the system.
SELECT KEYPAD FUNCTION
/
rl38 SELKEYPUNCT
1
-l-4,0
SKIP
I
This question indicates the desired keypad function
to be modified. Entrv of 0 will skio to the next group of
questions. The keypad functions’can be configured to
meet the needs of each installation for conditions such
as FIRE, PANIC, MEDICAL, etc.
KEYPAD CS CODE
J139CSCODBKPhl
Indicates the code transmitted to the Centr,al
Station when this keypad condition is activated. The
value KP#x displays the keypad condition number being
modified. This CS Code is similar to the zone code and
will follow the examples provided in the zone section.
DESCRIPTION
(IBDESCKI’BI
Indicates the description associated with the
keypad condition. This sixteen character description will
appear on the second line of an LCD display when the
condition is activated.
LEGEND-100 KEYPAD PROGRAMMING Page-33
Enter the alarm type to be used for this keypad
function. This defines the characteristics for this keypad
function to follow upon activation.
NOTE: Special’ care should be made when
selecting these alarm types since many of the keypad
conditions may require special handling such as no bell
or no display etc.
ENABLE RESTORE
pzEGz&q
Indicates whether the keypad condition is
restorable. If the condition is restorable then the system
reset command from the keypad will restore the
condition. The reset condition is either the user code or
the 3 + 1 keys as specified in question 040.
9.11. PARTTTlONS
’
’
;
This section of the Installer Programming sequence’
/
assigns the keypads to the partitions. The LEGEND-l 00
panel can accommodate up to slxteen keypads
consisting of eight LCD and eight LED keypads. Each
partition can handle multiple keypads, however each
keypad can be assigned to only one partition. If the
panel is set up in a non partitioned configuration, then
all active keypads should be assigned to partition
number 1. Keypad numbers l-8 are LED keypads, while
the LCD keypads are known as 9- 16.
Each partition display will contain sixteen indicators
reflecting whether that keypad has been assigned to the
partition. Entryof a Y indicates that the keypad belongs
to the partition while an N indicates that the keypad does
not belong. Note: Whenever a keypad is assigned to a
partition it will be removed from any previously defined
partition.
PARTITION SELECTION
p]
Enter the desired partition number for keypad
definition. To skip the partition questions enter 0. If the,?
system has been configured as a non-partitioned panel,
l
then the partition questions will be bypassed. _
KEYPAD ASSIGNMENT PARTITION #l
71
Enter the keypad assignment for the partition
number indicated by x. To access each of the sixteen
keypads within the partition use the FORWARD and
BACKWARD keys and the TOGGLE key will change the
Yes/No status of each keypad. Remember, keypads l-8
are LED while keypads 9-16 are LCD.
This question will be repeated for the number of
partitions specified in question number 11.
WARNING: If you intend on performing keypad
programming you must have at least one LCD keypad
assigned to the system even tf the configuration does
not contain any LCD keypads. .
5
.
PARTITION DESCRIPTION : ”
4
LEGEND-100 KEYPAD PROGRAMMING Page-34
9.12. AUTO UPLOAD PARAMETERS
A sixteen character description can be entered for
each partition.. This allows customization for each
installation. This description will appear on the second
line of the the SYSTEM READY display of LCD
keypads. Examplescould include SMITH RESIDENCE,
or STOCK ROOM #3, etc.
a
5
-/ --
The Legend-100 contains a system log feature
which stores the past 128 events which have occurred
in time sequence. This log can be viewed at the keypad
by an authorized installer, retrieved through the
EZ-Mate Downloader or EZ-Mate Programmer, or
transmitted to a remote serial printer and modem.
The transmission of the information to a remote
printer is known as the Auto Upload Feature. This
feature can be used for locations that require a printed
record of system activity. This Auto Upload feature is
in addition to any signals transmitted to the Central
Station.
The Auto Upload feature will transmit the system
log information to a printer located at the DUMP phone
number (see question # 002). If this number is blank
then the Auto Dump feature has not been selected. The
DUMP phone number can be located at the Central
Station, Alarm Company or any location with a modem
and printer. The Dump phone number can vary from
account to account.
The Auto Upload feature can be programmed to
transmit automatically upon either of the following
conditions;
- daily
- weekly
- monthly basis.
NOTE: If many of your customers utilize the Auto
Dump feature then it is important to stagger their
transmission times especially if they all transmit to the
same Dump telephone number.
AUTO UPLOAD TYPE
This question selects they the type of auto dump .
The options include;
NONE
DAILY
WEEKLY
MONTHLY
DAY OF MONTH
If the Auto Dump type is monthly, then this question
will specify the day of the month that the transmission
is desired. If the date selected does not exist in a
particular
month (example
Feb. 30) then the
transmission will occur on the next available day.
LEGEND-100 KEYPAD PROGRAMMING Page-35
DAY OF WEEK
If the reporting type is weekly, then this question.
will be asked for the desired. day of the week for
transmission. The TOGGLE key will scroll through the
days of the week from Sunday through Saturday.
HOUR OF DAY
~:;I~RT
HOUR 1
Enter the desired hour, in militarv (24 hour) time for
the transmission of the system log. This question will be
asked if the auto dump type is monthly, weekly or daily.
MINUTE OF HOUR
I150 REPORT MIN. 1
1 - (00-59)
I
Enter the desired minute for the transmission of the
system log. This question will be asked if the auto dump
type is monthly, weekly or daily.
MEMORY DUMP - # OF EVENTS
yi
The optional Auto Dump feature can be triggered
to transmit when the number of events stored reaches
a certain level. Enter the number of events required to
activate an Auto Dump.
This value can act as a threshold in the event of
above average system activity. For example, an
account might normally be programmed to transmit
monthly activity on a certain date and time. To suppress
the automatic transmission of event history enter 00.
AUTO DUMP ACCOUNT NUMBER
pzy
Enter a four digit account number which will be sent
whenever
this account
transmits
system
log
information. This account. number is for reference
purposes only and will be printed at the top of the remote
report for identification purposes.
This account number has no bearing on the account
numbers transmitted to the Central Station for alar-
activity.
AUTO UPLOAD DESCRIPTION 1
l
(
The printer at the DUMP phone number merely
answers the telephone
number and prints the
information which is transmitted. Provision is made for
the entry of four lines of comments to be transmitted as
a heading for each printout.
This description should be used to identify the
account at the remote printer with information such as
account name, address, special instructions, etc.
Enter the first line of descriptive information.
AUTO UPLOAD DESCRIPTION 2
pLGq
Enter the second line of descriptive information.
AUTO UPLOAD DESCRIPTION 3
71
Enter the third line of descriptive information.
AUTO UPLOAD DESCRIPTION 4
yrIiKy
Enter the fourth line of descriptive information.
9.13. SUMMARY OF DISPLAYS
CS Communications 001 - 023
User Attributes’
024 L -028
System Attributes
029 - 045
System Timing
046, - 061
System Funct. Code 062-084
Alarm Types
085 - 099
Trouble Type
loo- 110
Zone Definition
111 - 137
Keypad Conditions
138 - 142
Partition Assignment
143 - 145
Auto Dump
146 - 156
LEGEND-100 KEYPAD PROGRAMMING Page-36
i 0. PROGRAMMING LEVELS
‘:
QUICK PROGRAMMING
The following
list shows the programming
questions presented when performing
LEGEND-100
QUICK
programming.
000
Installer Programming Level
CS COMTWNICATIONS
ATTRIBUTES
001
Callback Number
003
CS #i Receiver Number
004
Pulses Per Second CWl
005
Parity CS#l
006
Format CS#l
007
CS #2 Receiver Phone Number
008
Pulses Per Second CS#2
009
Parity CS#2
010
Format CS#2
012
Account Number 1
013
Account Number 2
oi4
Installer Code
015
Touch Tone Dialing
LEGEND-100
KEYPAD
PROGRAMMING
Page
37
list shows the programming
questions presented in the intermcdiatc
programming
level within
the LEGEND-
100 panel.
000 Installer Programming
Level
CS COMMUNICATIONS
ATTRIBUTES
’
001 Callback Number
003 CS #l Receiver Number
004 Pulses Per Second CS#I
005 Parity CS#l
006 Format CS#l
007 CS #2 Receiver Number
008 Pulses Per Second CS#2
009 Parity CS#2
010 Format CS#2
012 Account Number 1
013 Account Number 2
014 Installer ,Code
015 Touch Tone Dialing
USER ATTRIBUTES
024 Select User Number
025 User Authorization
Level
026 User CS ID
SYSTEM AtiRIBUTES
029 Open/Close CS Reporting Type
030 Test CS Reporting Type
031 Test ‘Frequency
032 Enable 16 Zone Operation
033 Bypass Transmission
Type
SYSTEM TIMING
046 Bell Delay
047 Dialer Delay
048 Exit Delay
049 Entry Delay #l
050 Entry Delay #2
051 CS Test Time
052 AC Loss Delay
053 Exit Triggers
054 Entry Triggers
SYS FUNCTION
& TROUBLE
CODES
\. ’
062 Bypass Code
063 Abort Code
064 Opening Code
065 Closing Code
066 SystemTest
Code
067 AC Failure Code
068 AC Restore Code
069 Low Battery Code
070 Low Battery Restore
071 System Error Code
077 + - Ambush Enable
078 User 16 Ambush Code
ALARM TYPES
085 Select Alarm Type
086 Description
087 CS Code
088 CS Reporting Type
089 CS Restore Code
090 Bell Delay
091 Dialer Delay
092 Buzzer Enabled
093 Display Alarm
TROUBLE
TYPES
100 Select Trouble Type
101 Description
102 CS Code
103 CS Reporting Type
104 Dialer Delay
105 Bell Delay
106 Timeout Selection
ZONE ATTRIBUTES
111 Select Zone Number
112 Description
113CSCode
114 Enable Bypass
115 Enable Trouble
116 CS Restore
KEYPAD CONDITIONS
138 Select Keypad Function #
139 CS Code
140 Description
141 Alarm Type
LEGEND-100 KE(IPAD PROGRAMMING Page 38
questions arc presented when the programming
level is partitioned;
000 Installer Programming
Level
CS COMMUNICATIONS
ATTRIBUTES
001 Callback Number
003 CS #I Receiver Number
004 Pulses Per Second CS#l
005 Parity CS#l
006 Format CS#l
007 CS #2 Receiver Number
008 Pulses Per Second CS#2
009 Parity CS#2
010 Format CS#2
011 # of Partitions
012 Account Number 1
013 Account Number 2
014 installer Code
015 Touch Tone Dialing
USER ATTRIBUTES
024 Select User Number
025 User Authorization
Level
026 User CS ID
SYSTEM ATTRIBUTES
029 Open/Close CS Reporting Type
030 Test CS Reporting Type
031 Test Frequency
032 Enable 16 Zone Operation
033 Bypass Transmission
Type
SYSTEM TIMING
046 Bell Delay
047 Dialer Delay
048 Exit Delay
049 Entry Delay #1
050 Entry Delay #2
051 CS Test Time
052 AC Loss Delay
053 Exit Triggers
054 Entry Triggers
.
SYS FUNCTION
& TROUBLE CODES
062 Bypass Code
063 Abort Code
064 Opening Code
065 Closing Code
066 System Test Code
067 AC Failure Code
068 AC Restore Code
069 Low Battery Code
_.
070 Low Battery Restore
071 System Error Code
077 + - Ambush Enable
078 User 16 Ambush Code
ALARM TYPES
085 Select Alarm Type
086 Description
087 CS Code
088 CS Reporting Type
089 CS Restore Code
090 Bell Delay
091 Dialer Delay
092 Buzzer Enabled
093 Display Alarm
TROUBLE TYPES
100 Select Trouble Type
101 Description
102 CS Code
103 CS Reporting Type
104 Dialer Delay
105 Bell Delay
106 Timeout Selection
ZONE ATTRIBUTES
111 Select Zone Number
112 Description
113CSCode
114 Enable Bypass
115 Enable Trouble
116 CS Restore
KEYPAD CONDITIONS
138 Select Keypad Function #
139 CS Code
140 Description
141 Alarm Type
PARTITION
DEFINI’iION
143 Partition Selection
144 Partition Keypad Assignment
145 Partition Description
LEGEND-100 KEYPAD PROGRAMMING Page 39
L
questions will be asked when eniering the advanced keypad programming
mode on the Legend-100 panel;
000 Installer Programming Level
CS COMMUNICATIONS
001 Callback Number
04X2 Dump Telephone Number
003 CS #l Receiver Number
004 Pulses Per Second CS#l
005 Parity CS#l
006 Format CS#l
007 CS #2 Receiver Number
008 Pulses Per Second CS#2
009 Parity CS#2
010 Format CS#2
011 #of Partitions
012 Account Number 1
013 Account Number 2
014 Installer Code
015 Touch Tone Dialing
016 CS Dialer Enable
017 Remote Operations
018 Remote Arming
019 Remote Bypass
020 # of Attempts
021# of Rings to Pickup
022 Extended Antijam
023 Extended Acknowledge
,I USER ATTRIBUTES
024 Select User Number
025 User Authorization Level
026 User CS ID
027 User Partition Assignment
028-User Master Partition
SYSTEM ATTRIBUTES
029 Open/Close CS Rep.Type
030 Test CS Reporting Type
031 Test Frequency
032 Enable 16 Zone Operation
033 Bypass Transmission Type
034 Auto Unbypass Enable
035 Arm Outputs Level
036 Bell Test At Arming
037 Bell Ringback at Closing
038 Sounder Ringback Enable
039 Fire Reset Verification
040 Enable Reset Key Function
041 En. Rest CO Follow Loop
042 Action on Abort
043 Enable Keypad Commands
044 Enable Keypad Directory
045 Enable Multi Partition Mode
SYSTEM TIMING
046 Bell Delay
047 Dialer Delay
048 Exit Delay
049 Entry Delay #l
050 Entry Delay #2
05 1 CS Test Time
052 AC Loss Delay
053 Exit Triggers
054 Entry Triggers
055 Timeout #l
056 Timeout #2
057 Timeout #3
058 Global Bell Lockout
059 Local Bell Lockout
060 Giobal Dialer Lockout
061 Local Dialer Lockout
SYS FUNCT. CODES
062 Bypass Code
063 Abort Code
064 Opening Code
065 Closing Code
066 System Test Code
067 AC Failure Code
068 AC Restore Code
069 Low Battery Code
070 Low Battery Restore Code
071 System Error Code.
072 System Error Reset
073 Download Code
074 Buzzer on AC Loss
075 Buzzer on Low Battery
076 Buzzer on System Error
077 + - Ambush Enable ‘.
078 User 16 Ambush Code
079 24 Hour AC Trouble
080 24 Hour Low Battery
08124 Hour System Error
082 Trouble Type AC Failure
083 Trouble Type Low Battery
084 Trouble Type System Error
ALARM
TYPES
085 Select Alarm Type
086 Description
087 CS Code
088 CS Restore
089 CS Reporting TM
090 Bell Delay
091 Dialer Delay
092 Buzzer Enabled
093 Display Alarm
094 Timeout Selection
095 Alarm Priority
.096 Momentary Triggers
097 Latched Triggers
098 Relay 1 Select
099 Relay 2 Select
123 Alarm on Open
124 Alarm on Short
125 Trouble on Open
126 Trouble on Short
127 Entry Delay
128 Enable Lockout
.
129 CS Bypass
130 Enable Trouble Buzzer
13 1 Enable Chime
132 Enable 75OMS Response
133 Enable as Keyswitch’
134 Enable Verification.
135 Silence After Fire Restore
136 Pulse Count Tie
137 # Pulses
.TROUBLE
TYPES
100 Select Trouble Type
101 Description
102CSCcde
1
103 CS Reporting Type
104 Dialer Delay
105 Bell Delay
106 Timeout Selection
107 Momentary Triggers
108 Latched Triggers
109 Relay 1 Select
110 Relay 2 Select
ZONE ATTRIBUTES.
111 Select Zone Number
112 Description
113 CS Code
114 Enable Bypass
115 Enable Trouble
116 CS Restore
117 Partition Selection
11824HourAlarm
119 24 Hour Trouble
120 AlarmType -I
121 Trouble Type
122 Zone Type
KEYPAD
CONDITIONS
138 Select Keypad Function #
139 CS Code
140 Description
141 Alarm type
142 Enable Restore
PARTITION
DEFINLTION
143 Partition Select&~
144 Partition Keypad:
,
145 Partition Description
AUTO UPLOAD PARAM.
146 Auto Upload Type
147 Day of Month
148 Day of Week
149’Report Hour
‘150 Report Minute
151 Memory Dump # Events
152 Auto Dump Account #
153 Auto Dump Description #l
154 Auto Dump Description #2
155 Auto Dump Description #3
156 Auto Dump Description #4
LEGEND-l 00 KEY PAD PROGRAMMING Page 40
11. SYSTEM DEFAULTS
.‘.
.-
.
Report
Date:
4-6-89
CUSTOMER NO: ,777777 PAGE #1
---i----------c--
CUSTOMER MASTER INFORMATION ---------------
-
NAME:
System Defau.lts-
Legend-100
ADDR:
Revision
3.1
CITY:
STATE:
ZIP:
0
DEVICE TYPE: Legend 100
DOWNLOAD REV: 31
i\
A--
,/”
; ii----------------
CENTRAL STATION C@4hkATIONS
ATTRIBUTES ----------------
:iCS CALLBACK NUMBER:
h!DUkfP PHONE NUMBER:
"CS. #l PHONE NUMBER:
234
CS #2 PHONE NUMBER:
cs #l
ks
#2
--
# PULSES: 20 PPS 2300
PARITY: No
MESSAGE FMT.:
Standard
--
# PULSES: 20 PPS 2300
PARITY: No
MESSAGE FMT.:
Standard
TOUCH TONE DIALING:
FcIT ?'k ENABLE:
*~PER:
C$ R
OTE'DISARM:
CS RE&OTE BYPASS:
INSTALLER CODE:
----------------
USER
.USER
ACCESS CODE
1
1234
:
'4
5'
-6
i
9
10
,ll
12
13
14
15
N
NUMBER OF ATTEMPTS:
._ 8
Y
RING COUNT:
8
Y
EXTENDED
Y
EXTENDED
Y
ANTIJAM:
N
ACKNOLEDGEMENT: N
,.*
ATTRIBUTES ----------------
ID
AUTH.
ORIGIN
PARTITION ACCESS
11
1
Ynnnnnnn
2
2
1
Ynnnnnnn
3
2
1
Y n n n n n..n n
4
2
1
Ynnnnnnn
5
2
1
Ynnnnnnn
6
2
1
Ynnnnnnn
7
2'
1
Ynnnnnnn.
8
2
1
Ynnnnn.nn
9
2.
1
Ynnnnnnn
A
2
1
Ynnnnnnn
B
2
1
Ynnnnn'nn
C
,2
1
Ynnnnnnn
.D
2
1
Ynnnnnnn
E
2
'1
Ynnnnnnn
F
2
1
Ynnnnnnn
0
2
1
Ynnnnnnn
LEGEND-100 KEYPAiD PROGRAMMING Page 41
*
CUSTOMER NO: 777777
PAGE 2
----------------
SySTm
hiTRIBUTES
w-i
O/C CS REPORT TWE.:
No Transmission,.
TEST CS REPORT TYPE:,
No Tranemission
TEST FREQUENCY:
None
16 ZONE OPERATION:
N
BYPASS TRANS TYPE:
Upon
Bypass
AUTO UNBYPASS EMABLE: Y
ARMING OUTPUT LEVEL:
High
USER 16 AS AMBUW:
N
KEYPAD COMMANDBNAB:.Y
;
MULTI PARTITION MODE: Y
-------------
AN=-&.*
BELL TEST AT ARMING:‘
.N
.('
\
BELL RINGBACK AT CLOSING:
N
..\
,
SOUNDER RRACK
ENABLE:
Y
FIRE RESET VERIFICATION:
Y
RESET KEY FUNCTION:
N
RESTORE TO FOLLOW LOOP:
N
ACTION ON ABORT:
No Abort.
NORMAL (t/-)
AMBUSH:
N
KEYPAD DIRECTORY ENAB:
Y
----------------
SYSTEM TiMING
----------------
BELL DELAY:
15 Second
DIALER DELAY:
,
15 Second
EXIT DELAY:
60 Second
ENTRY DELAY #l:
30 Second
ENTRY DELAY #2:
60 Second
CS TEST DELAY:
3AM
AC LOSS DELAY:
15 Minute
CUTOFF TIMER # 1
14 Minute
CUTOFF TIMER # 2
Infinite
CUTOFF TIMER # 3
:
2 Minute
/
LOCAL
GLOBAL
BELL LOCKOUT COUNT:
15
15
DIALER LOCKOUT COUNT:
15
15
12345678
EXIT TRIGGERS
nnnnnnnn
ENTRY TRIGGERS
nnnnnnnn
----------------
SYSTEM'FUNCTION CODES ----------------
BYPASS CODE:
0
ABORT CODE:
D
OPENING CODE:
B
CLOSING CODE:
C
SYSTEM TEST CODE:
00
----------------
SYSTEM TROUBLE CODES ----------------
AC FAILURE
LOW BATTERY
SYSTEM ERROR
CODE
9
9
9
RESTORE
E
E
E
BUZZER?
Y
Y
N
24 HOUR?
Y
Y
N
TRBL. TYPE
1
2'
4
‘.---I
.//.,,
,’ --’
,
--4-----j
,i
I
,:--
LEGEND-l 00 KE;~P~D~~.R~~GUWlMING Page 42
CS RESTORE E
E
E
BELL DEL?
N
N
N
DIAL DELAY? N
N
N
BUZZER?
Y
Y
Y
DISPLAY?
Y.
Y
Y
TIMER SEL.
2
1
1
AL. PRIOR.
.2'
3
4
#
DESCRIPTION
1
FIRE
!!!!
2
EMERGENCY
3
BURGLARY
4.
BURGLARY
5
SIL.
PANIC
6
EMERGENCY
7
DURESS
8
Spare
9
Spare
10
Spare
11
Spare
12
Spare
13
Spare
14
Spare
“-- .
Report
Date:
4-6-89
CUSTOMER NO: 777777
PAGE! 3
TYPES ----------------
4
5
3
‘2
E
E
Y
N
N
N
Y
N
Y
N
11
4
4
9
10
F
F
E
E
N
N
N
N
N
N
N
N
11
4
4
MOMENTARY
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
6.
7
8
2
2
F
E
E
E
N
N
N
N
N
N
Y
N
N
k
N
N
11
5
2
4
LATCHED
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
REL#l
Pulse
Latch
Latch
Latch
None
None
None
None
None
None
None
None
None
None
None
None.
,&,,-,,,,-----,,
TROUBLE
TYPES
----------------
1
2
CS CODE
F
F
BELL DELAY N
N
DIALER DEL
N
N
TIMEOUT SEL 1
1
3
4
F
F
N
N
N.
N
1
1
MOMENTARY
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
5
6
F
F
N
N
N
N
1
1
:IATCHED
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
nnnnnnnn
7
F
N
N
1
TYPE
DESCRIPTION
1'
AC Loss'
2
Low Bat.
3-
Grnd Fault
4
System Err
5.
FIRE TRBLE
6:
Trouble
7.
Spare
8
Spare
RELAY#l RELAY#2
REPORT TYPE
None
None
No Transmission
None
None
No Transmission
None
None
No Transmission
.None
None
No Transmission
.None
None
No Transmission
None
None
No Transmission
None
None
No Transmission
None
None
No Transmission
11
F
E
N
N
N
N
1
4
12
F
E
N
N
N
N
1
4
REL#2
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
8
F
N
N
1
13
F
E
N
N
N
N
1
4
14
F
E.
N
N
N
N
1
h
15
16
F
F
E
E
N
N
N
N
N
N
N
N
11
4
4
REPORT TYPE
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Cnly
CS# 1
CS#
@nly
1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
CS# 1 Only
LEGEND-100 KEYPAD PROGRAMMING Page 43
CUSTOMER NO: 777777
PAGE 4
----------------
-----w-----s----
ZONE
A’rTRIBUTES
CS CODE
:
BYPASS?
Y
TRB ENAB? N
REST CS?
N
PARTIT.
1
24 HR AL? N
24 HR TR? N
AL TYPE
3
TR TYPE
6
AL OPEN? Y
AL SHORT? Y
TR OPEN? N
TR SHORT? N
SEL EN DL 2
LOCKOUT? N
CS BYPASS N
CHIME?
N
750 MS?
N
KEYSWITCH N
VERIF?
N
SL FR RES N
BUZ TRB?
N
PLS TIME
15
PLS CNT
0
:
Y
N
N
1
N
N
3
6
Y
Y
N
N
2'
N
N
N
N
N
N
N
N
15
0
3
4
3
3
Y
k
N
N
N
N
1
1
N
N
N
N
3
3
6
6
Y
Y
Y
Y
N
N
N
N
2
2
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
15
15
0
0
Y
N
N
1
N
N
3
6
Y
Y
N
N
2
N
N
N
N
N
N
N
N
15
0
3”
Y
N
N
1
N
N
3
6
Y
Y
N
N
2
N
N
N
N
N
N
N
N
15
0
ZONE
1
2
3
4
5
6
7
t
10
11
12
13
14
15
16
DESCRIPTION
Front
Door
Interior
Motion
Master
Bedroom
Bedroom
Living
Room
Dining
Room
Den
Smoke Detector
Zone 9
Zone 10
Zone 11
Zone 12
Zone 13
Zone 14
Zone 15
Panic
7
8
9
10
11
3
1
3
3
3
Y
N
Y
Y
Y
N
Y
N
N
N
N
N
N
N
N
1
1
1
1
1
N
Y:
N
N
N
N
Y
N
N
N
3
1
3
3
3
6
5
6
6
6
Y
N
Y
Y
Y
Y
Y"
Y
Y
Y
N
YjS N
N
N
N
N'
N
N
N
2
2'
2
2
2
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
N
N
N
N
Y
N
N
N
N
N
N
N
N
15
15
15
15
15
0
0
0
0
0
ZONE TYPE
Exit
/ Entry
12
3
Y
N
N
1
N
N
3
6
Y
Y
N
N
2.
N
N
N
N
N
N
N
N
15
0
13
3
Y
N
N
1
N
N
3
6
Y
Y
N
N
2
N
N
N
N
N
N
N
N
15
0
Interior
E/E Follower
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
Perimeter
14
15
3
3
Y
Y
N
N
N
N
1
1
N
N
N
N
3
3
6
6
Y
Y
Y
Y
N
N
N
N
2
2
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
15
15
0
0
N
N
N
1
Y
N
2
6
Y
Y
N
N
2
N
N
N
N
N
N
N
N
15
0
LEGEND-100 KEYPAD PROGRAMMING Page 44
- .-.-,-
--
P
7,
_ +
CUSTOMER NO: 777777
PAGE 5
---------------~‘KEypAD
FUNCTIONS
----------------
DESCRIPTION
CS CODE
AL. TYPE
CS REST
1
PANIC
2
2
N
2
MEDICAL
2
6
>
N
3
SILENT
PANIC
2
5
N
4
Duress
2
7
N
----------------
PARTITION
DEFINITION
----------------
ACCT#l
ACCT#2
KEYPADS
DESCRIPTION
LED
LCD
12345678
12345'678
1
000
000
nnnnnnnn
YYnnnnnn
2
nnnnnnnn
nnnnnnnn
3
nnnnnnnn
nnnnnnnn
4.
nnnnnnnn
nnnnnnnn
5
nnnnnnnn
nnnnnnnn
6
nnnnnnnn
nnnnnnnn
7
nnnnnnnn
nnnnnnnn
8
nnnnnnnn
nnnnnnnn
~;i-;;i-G-&
t()G;E
P-TERS
--------------
DAY OF MONTH:
'
01
DAY OF WEEK:
SUNDAY
REPORT HOUR:
00
REPORT MINUTE:
00
MAX # EVENTS:
99
DUMP ACCT NO:
0000
DESCRIPTION #1:
DESCRIPTION #2:
DESCRIPTION #3:
DESCRIPTION #4:
END OF REPORT
LEGEND-l 00 KEYPAD PROGRAMMING Page 45
Fire Burglary Instruments, Inc., its parents, subsidiaries, divisions and affiliates (“Seller”) warrants its products to be in
conformance with its own plans and specifications and to be free from defects in materials and workmanship under
normal use and service for 18 months from the date stamp control on the product, or for products not having a date
stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter
period, in which case the shorter period shall apply. Seller’s obligation shall be limited to repairing or replacing, at its
option, free of charge for materials or labor, any part which is proved not in compliance with Seller’s specifications or
proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this
Limited Warranty or otherwise, if the product is altered or improperly repaired or serviced by anyone other than Seller.
For warranty service, return product transportation prepaid, to Factory Service, 163 Eileen Way, Syosset, New York
11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTIC-
ULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN
NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES
FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF
LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS OWN NEGLIGENCE OR FAULT
Seller does not represent that the products it sells may not be compromised or circumvented; that the products will
prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the products will in all cases
provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may ~
only reduce the risk of a burglary, robbery or fire without warning, but it is not insurance or a guarantee that SUC~-‘-‘~‘~
occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL.&
LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM I-HE
PRODUCT FAILED TO GIVE WARNING. However, if Seller is held liable, whether directly or indirectly, for any loss or
damage arising under this Limited Warranty or otherise, regardless of cause or origin, Seller’s maximum liability shall
not in any case exceed the purchase price of the product, which shall be the complete and exclusive remedy against
Seller.
This warranty replaces any previous warranties and is the only warranty made by Seller on this product. No increase or
alteration, written or verbal, of the obligations of this Limited Warranty is authorized.