ERNITEC 230/3 Series Manual 

File Specifications

Brand: ERNITEC
Category: Microphone system
Model: 230/3 Series (Manual ), prcM/uXSGSv5k
File Type: PDF
File Size: —
Pages: 8 pages

Download PDF

Download ERNITEC 230/3 Series Manual (8 pages)

Read Online:

Read the ERNITEC 230/3 Series Manual  online using the built-in PDF viewer.

Key Pages of Document

Twisted Pair Video Transmission

Series 230/3 Boxed versions PWR BVR 230-G DANGER MAINS IN N L ernitec 0498-00083 V.0.1 VIDEO IN VIDEO OUT SYNC GND BAS- BAS+ MF-HF LF GAIN J3 + J1 1 3 - + ~ ~ 1 3 1 3 J2 ERNITEC DENMARK, HØRKÆR 24, DK-2730 HERLEV, DENMARK PHONE. + 45 44 50 33 00, FAX: + 45 44 50 33 33, E-MAIL: [email protected] ERNITEC UK, PHONE: + 44 (0) 1903 ...

The following units are covered in this manual:

� Boxed video transmitter BVT-230. � Boxed video receiver BVR-230-1GV/3. � Boxed video repeater BVX-230-1GV/3. All three units are fully compatible with other Ernitec twisted pair video equipment. However, the specified transmission distance, and adjustments, assumes the use of Series 230 equ ...

Terminals marked with hazardous live symbol requires installation by an instructed

person. The BVT/R/X-230 must be used with a 3-wire mains connection (2W+PE @ min. 0,75mm2). If permanently connected to mains, a readily accessible disconnect device shall be incorporated in the building installation wiring. If pluggable connection to mains, ...

For optimum performance, under all lighting conditions, it is highly recommended to use a

Grey scale/Multiburst Video Generator, and an Oscilloscope for the adjustment. Especially when using digital video equipment - like DVR’s - it is important to adjust for best possible video performance. 1. Connect the Video Generator to the camera input of ...

Twisted Pair Cable Specifications

The cables are the most important part of a Twisted Pair Video installation, and the overall performance and transmission distance, depends on the selected twisted pair cable. Please note, that twisted pair cables with stranded conductors are NOT suitable - the conductors must be solid. When shielded cables are used the tran ...

Immunity: EN50130-4, Emission: EN6000-6-3

EMC/EMI Approvals IP 65 Protection kg 0,8 Weight excl. cable glands mm 60 145 220 Dimensions, L x W x H Enclosure @ 86-106 KPa % 85 Humidity oC 50 - 25 Temperature Environment @ 115VAC mA BVX Max. 90 BVR Max. 60 BVT Max. 50 @ 230VAC mA BVX Max. 45 BVR Max. 30 BVT Max. 25 Power consumpti ...

Up to 2200 meters twisted pair cable

Local monitor(s) (optional) Shield: DO NOT CONNECT! BVX-230-1GV/3 188,3 mm Drilling dimensions: Up to 2200 meters twisted pair cable BVT-230 BVR-230 2 Vpp 3 Vpp +3 dB @5MHz 4 Vpp +6 dB @5MHz <600 m <900 m >900 m P1: Bal. output voltage CAT5E 24AWG (0.5mm) 2 Vpp 3 Vpp +3 dB @5MHz 4 Vpp +6 dB @5MHz <1000 m <1500 m >1500 m P ...

Up to 2200 meters twisted pair cable

90 mm 188,3 mm BVT-230 Drilling dimensions: Shield: DO NOT CONNECT! - + MAINS N IN L DANGER 0498-00082 V0,1 0498-00082 V0,1 BVT230 BVT230 ernitec ernitec PWR OUT VIDEO VIDEO IN J3 + + J1 J2 - + BAS POS ...