Fermax MEET KIN Installer Manual
Text of the manual
MEET KIN PANEL
INSTALLER'S MANUAL
ENGLISH Version
This manual corresponds to firmware version V2.0.
FERMAX ELECTRÓNICA S.A.U.
MEET DIGITAL VIDEO Panel manual available at https://www.fermax.com/qr/meet/
Copyright Notice
Fermax and Fermax MEET panel are trademarks of Fermax Electronica S.A.U. registered in
the European Union and other countries.
© FERMAX ELECTRÓNICA S.A.U., 2018.
1 Product Introduction
Overview
Speaker
High definition camera 1,2Mpx
Lighting for night vision with LEDs
TFT and touch screen
Mifare reader
Microphone
Slider
Motion sensor
Panel Display Screen
2 Functions Introduction
Call apartment
Call guard unit
Call volume settings
Door opening, relay delay settings
Connect exit button
Speech
Door opened and tamper alarm
Lift control (Only when installed)
Access Code
Mifare reader
Alarm management by access control
Face Recognition for
2.1.1 Block Panel call apartment
Visitors need enter apartment number followed by
to confirm. For example, if the resident
lives in apartment 2601, the visitor should enter: 2601 and press
2.1.2 General Entry Panel call apartment
Visitors need to enter block number followed by a 4 digits apartment number followed by
to confirm. For exam
Call Guard Unit
2.2.1 Block Panel Call Guard Unit
The visitor or resident can call the guard unit by touch concierge icon , then select the concierge
that they want to call .This call can be made from all Block Entry Panels.
2.2.1 General Entry Panel Call Guard Unit
The visitor or resident can call the guard unit by touch concierge icon , then select
Press ACCESS CODE icon to access code function, entering the access code followed by KEY
icon to confirm.
If the access code is correct the door will open and release the lock.
You can enable or disable the function at web of the panel.
The access code to be defined at web of the panel, Maximum access code 8.
Face Recognition
Press FACE RE
Resident can access to their corresponding entrance by passing their authorized Mifare card,
the door will open and release the lock.
The Mifare card data is to be added through management software, Maximum 100,000 Mifare
cards.
2.6 About
Enter code 9999 followed by
icon to confirm, The ABOUT information will show.
You can get informatio
10/100Mbps RJ45 Port.
+, —: 12Vdc Power Input.
C, NO, NC: Relay contacts for release lock, the double terminals are the same connection.
+5V, —, WD0, WD1: Wigand-26 protocol output or input.
BS, —: Exit button.
—, SP: Door-open sensor.
485+, 485-: To lift control gateway, F01491 (4 relay m
Panel (mm): 185(W) ×405(H) ×53(D)
Power supply: 12Vdc/POE
Standby current: 330mA
Working current: 500mA
Technical specifications of the display:
-Size: 10 inch
-Format: 16:9
-Resolution: 1024*600
Camera pixel: 1.2 megapixels
90o visual angle: Vertical 72º, Horizontal 54º Minimum illumination: 0.5Lux
Maximum conversation ti