INSTALLER'S MANUAL ENGLISH Version This manual corresponds to firmware version V2.0. FERMAX ELECTRÓNICA S.A.U.

MEET DIGITAL VIDEO Panel manual available at https://www.fermax.com/qr/meet/

Copyright Notice Fermax and Fermax MEET panel are trademarks of Fermax Electronica S.A.U. registered in the European Union and other countries. © FERMAX ELECTRÓNICA S.A.U., 2018.

1 Product Introduction

Overview Speaker High definition camera 1,2Mpx Lighting for night vision with LEDs TFT and touch screen Mifare reader Microphone Slider Motion sensor

Panel Display Screen

2 Functions Introduction  Call apartment  Call guard unit  Call volume settings  Door opening, relay delay settings  Connect exit button  Speech  Door opened and tamper alarm  Lift control (Only when installed)  Access Code  Mifare reader  Alarm management by access control  Face Recognition for

2.1.1 Block Panel call apartment

Visitors need enter apartment number followed by to confirm. For example, if the resident lives in apartment 2601, the visitor should enter: 2601 and press 2.1.2 General Entry Panel call apartment Visitors need to enter block number followed by a 4 digits apartment number followed by to confirm. For exam

Call Guard Unit

2.2.1 Block Panel Call Guard Unit The visitor or resident can call the guard unit by touch concierge icon , then select the concierge that they want to call .This call can be made from all Block Entry Panels. 2.2.1 General Entry Panel Call Guard Unit The visitor or resident can call the guard unit by touch concierge icon , then select

Press ACCESS CODE icon to access code function, entering the access code followed by KEY

icon to confirm. If the access code is correct the door will open and release the lock. You can enable or disable the function at web of the panel. The access code to be defined at web of the panel, Maximum access code 8. Face Recognition Press FACE RE

Resident can access to their corresponding entrance by passing their authorized Mifare card,

the door will open and release the lock. The Mifare card data is to be added through management software, Maximum 100,000 Mifare cards. 2.6 About Enter code 9999 followed by icon to confirm, The ABOUT information will show. You can get informatio

10/100Mbps RJ45 Port.

 +, —: 12Vdc Power Input.  C, NO, NC: Relay contacts for release lock, the double terminals are the same connection.  +5V, —, WD0, WD1: Wigand-26 protocol output or input.  BS, —: Exit button.  —, SP: Door-open sensor.  485+, 485-: To lift control gateway, F01491 (4 relay m

Panel (mm): 185(W) ×405(H) ×53(D)

Power supply: 12Vdc/POE Standby current: 330mA Working current: 500mA Technical specifications of the display: -Size: 10 inch -Format: 16:9 -Resolution: 1024*600 Camera pixel: 1.2 megapixels 90o visual angle: Vertical 72º, Horizontal 54º Minimum illumination: 0.5Lux Maximum conversation ti