Multifunction Process Calibrator

Users Manual January 2005 Rev. 3, 5/18 © 2005-2018 Fluke Corporation, All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. 1.888.610.7664 [email protected] Fluke-Direct.com ...

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate su ...

Table of Contents

Title Page Introduction .................................................................................................................... 1 Contact Fluke ................................................................................................................. 1 Standard Equipment ....................................................................................................... 3 Safety Information .......................................................................................................... 3 Ex Hazardous Areas ........................................................................................... ...

Current Measurement with Loop Power .................................................................... 19

Measuring Electrical Parameters (Lower Display) .................................................... 21 Measuring Temperature ............................................................................................ 22 Using Thermocouples .......................................................................................... 22 Using Resistance-Temperature Detectors (RTDs) ............................................... 25 Measuring Pressure ......................................................................... ...

Service Center Calibration or Repair ......................................................................... 51

Replacement Parts .................................................................................................... 51 Accessories .................................................................................................................... 53 Specifications ................................................................................................................. 55 DC Voltage Measurement ......................................................................................... 55 DC Voltage Sou ...

Multifunction Process Calibrator

Introduction WWarning Read "Safety Information" before using the Calibrator. The Fluke 725Ex Multifunction Process Calibrator (hereafter referred to as “the Calibrator”) is a handheld, battery-operated instrument that measures and sources electrical and physical parameters. For a summary of source and measurement functions, see Table 1. In addition to the functions in Table 1, the Calibrator has the following features and functions: • A split-screen display - The upper display allows the user to measure volts, current, and pressure only. The lower display allows the user to measure and source volts, current, pre ...

Table 1. Summary of Source and Measure Functions

Function Measure Source dc V 0 V dc to 30 V dc 0 V dc to 10 V dc dc mA 0 to 24 mA dc 0 to 24 mA Frequency 1 CPM to 10 kHz 1 CPM to 10 kHz Resistance 0 Ω to 3200 Ω 15 Ω to 3200 Ω Thermocouple Types E, J, K, T, B, R, S, L, U, N, mV, XK, BP RTD (Resistance- Temperature Detector) Ni120 Pt100 Ω (385) Pt100 Ω (3926) Pt100 Ω (3916) Pt200 Ω (385) Pt500 Ω (385) Pt1000 Ω (385) Pressure Fluke 750PEx series modules ranging from 10 inH2O to 3000 psi Fluke 750PEx series modules ranging from 10 inH2O to 3000 psi using an external pressure source (hand pump). Other functions Loop ...

Mulitfunction Process Calibrator

Standard Equipment 3 Standard Equipment The items listed below and shown in Figure 1 are included with the Calibrator. If the Calibrator is damaged or something is missing, contact the place of purchase immediately. To order replacement parts, see Replacement Parts in Table 9. • TL75 test leads with caps (one set) • Alligator clips (one set) • Stackable alligator clip test leads (one set) • Fluke 725Ex CCD • Fluke 725Ex Safety Information • 4 AA Batteries (installed) • Hex Key, 5/64 in., short arm Safety Information A Warning statement identifies conditions and actions that pose a hazard(s) to the user. A ...

terminals to other equipment, the Vmax and Imax ratings

on the other equipment must exceed the Voc and Isc ratings for the terminals connected to on the 725Ex calibrator. In addition to matching voltage and current entity parameters, it is also necessary to verify that capacitance and inductance has not been exceeded. Again, the Calibrator CCD identifies the maximum capacitance (Ca) and maximum inductance (La) that is permitted based either on the intrinsic safety barrier ratings or on the Calibrator ratings for the specific terminals used. As an example, the Calibrator CCD explains that the capacitance of each unit connected in th ...

Mulitfunction Process Calibrator

Ex Hazardous Areas 5 W Warning To prevent fire, explosion, or personal injury: • Use the Calibrator only as described in this User Manual and the Fluke 725Ex CCD (Concept Control Drawing) or the protection provided by the Calibrator may be impaired. • Inspect the Calibrator before use. Do not use it if it appears damaged. • Check the test leads for continuity, damaged insulation, or exposed metal. Replace damaged test leads. • When using probes, keep fingers behind the finger guards on the probes. • Never apply more than 30.0 V between the input terminals, or between any terminal and earth ground. • Applying ...

Disconnect test leads from the circuit under test before changing to another measure or source

function. • When measuring the pressure of toxic or flammable gases, care must be taken to minimize the possibility of leakage. Confirm that all pressure connections are properly sealed. • Do not use in a damp or wet environment. WCaution To avoid possible damage to Calibrator or to equipment under test: • Disconnect the power and discharge all high-voltage capacitors before testing resistance or continuity. • Use the proper jacks, function, and range for the measurement or sourcing application. • The MEASURE/SOURCE terminal ...

Mulitfunction Process Calibrator

Ex Hazardous Areas 7 100% 25% 25% RECALL STORE SETUP 0% Stackable Test Leads TL75 Test Lead Set AC72 Alligator Clips V mA MEASURE SOURCE / MEASURE 30V 24mA MAX ALL TERMINALS 4W 3W V Hz RTD mA+ mA- TC COM COM LOOP AC175 Alligator Clips aly01f.eps Figure 1. Standard Equipment 1.888.610.7664 [email protected] Fluke-Direct.com ...

Table 2. Symbols

Symbol Meaning Symbol Meaning W WARNING. RISK OF DANGER.  Consult user documentation. + Power ON/OFF T Double insulated  Earth ground f Pressure  Battery ) Certified by CSA Group to North American safety standards.  Direct current  Conforms to relevant Australian Safety and EMC standards.  Conforms to relevant South Korean EMC Standards. ~ This product complies with the WEEE Directive marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directiv ...

Mulitfunction Process Calibrator

Ex Hazardous Areas 9 Faults and Damage Applying a voltage greater than 30 V to the input of the Calibrator invalidates its Ex Approval and may impair its safe operation in an Ex-hazardous area. See “Ex Hazardous Areas”. If there is any reason to suspect that the safe operation of the Calibrator has been affected, it must be immediately withdrawn from use, and precautionary measures must be taken to prevent any further use of the Calibrator in an Ex-hazardous area. See Ex Hazardous Areas. Fully observe all instructions, warnings, and cautions contained in this manual. In case of doubt due to translation and/or printi ...

) Class I Div. 1 Groups B, C, and D

Class I Zone 0 AEx/Ex ia IIB 171 °C • Ta = -10 °C… +55 °C • Manufactured by Fluke Corporation 6920 Seaway Blvd. Everett, WA 98203, USA Getting Acquainted with the Calibrator Input and Output Terminals Figure 2 shows the Calibrator input and output terminals. Table 3 explains their use. V mA LOOP V mA TC RTD °C °F Hz 100% 25% 25% RECALL ZERO MEAS SOURCE STORE SETUP 0% MULTIFUNCTION PROCESS CALIBRATOR 725Ex 8 7 6 5 4 3 2 1 aly05f.eps Figure 2. Input/Output Terminals and Connectors 1.888.610.7664 [email protected] Fluke-Direct.com ...

Mulitfunction Process Calibrator

Getting Acquainted with the Calibrator 11 Table 3. Input/Output Terminals and Connectors No Name Description  Pressure module connector Connects the Calibrator to a pressure module. ,  MEASURE V, mA terminals Input terminals for measuring voltage, current, and supplying loop power.  TC input/output Terminal for measuring or simulating thermocouples. This terminal accepts a miniature polarized thermocouple plug with flat, inline blades spaced 7.9 mm (0.312 in) center to center. ,  SOURCE/ MEASURE V, RTD, Hz, Ω terminals Terminals for sourcing or measuring voltage, resistance, frequency, and RTDs. , ...

Figure 3 shows the Calibrator keys and Table 4 explains

their use. V mA LOOP V mA TC RTD °C °F Hz 100% 25% 25% RECALL ZERO MEAS SOURCE STORE SETUP 0% MULTIFUNCTION PROCESS CALIBRATOR 725Ex V mA LOOP V mA TC RTD °C °F Hz 100% 25% 25% RECALL ZERO MEAS SOURCE STORE SETUP 0% MULTIFUNCTION PROCESS CALIBRATOR 725Ex 1 8 9 10 2 3 4 6 7 5 12 11 13 14 15 16 17 18 19 20 V mA MEASURE SOURCE / MEASURE 30V MAX ALL TERMINALS 4W 3W V Hz RTD mA+ mA- TC COM COM LOOP V mA MEASURE SOURCE / MEASURE 30V MAX ALL TERMINALS 4W 3W V Hz RTD mA+ mA- TC COM COM LOOP REFER TO CONTROL DRAWING: ANSCHLUSSSCHEMA BEACHTEN: SUIVRE LE SCHÉMA DE CONN ...

Mulitfunction Process Calibrator

Getting Acquainted with the Calibrator 13 Table 4. Key Functions No. Key Description   Turns the power on and off.   Selects voltage, mA, or loop power measurement functions in the upper display. Clears the switch test. See “Switch Test”.   Selects the pressure measurement function in the upper display. Repeated pushes cycle through the different pressure units. Use for pressure switch test. See “Switch Test”.   Zeros the pressure module reading. This applies to both upper and lower displays.   Turns backlight on and off.   Toggles between frequency and ohms measurement and so ...

Table 4. Key Functions (cont.)

No. Key Description + +   Disables Shut Down Mode Enables Shut Down Mode     Increases or decreases the source level. Cycles through the 2-, 3-, and 4-wire selections. Moves through the memory locations of calibrator setups. In Contrast Adjustment mode; up-darkens contrast, down-lightens contrast.   Retrieves a previous calibrator setup from a memory location.   Saves the Calibrator setup. Saves Contrast Adjust setup.   Cycles the Calibrator through MEASURE and SOURCE modes in the lower display.   Selects the TC (thermocouple) measurement ...

Mulitfunction Process Calibrator

Getting Acquainted with the Calibrator 15 Display Figure 4 shows the elements of the display. Low Battery Symbol Loop Annunciator Memory Locations for Calibrator Setups Units Display Auto Ramp Mode Indicator sh07f.eps Figure 4. Elements of a Typical Display 1.888.610.7664 [email protected] Fluke-Direct.com ...

Test Equipment PDF Instructions

EBD-A20H
ZKETECH EBD-A20H
02.09.2026 5 pages

ZKETECH Release Date 2017-01-01 Multifunction Electronic Load (EBD-A20H) Technical guide for the ZKETECH EBD-A20H Test Equipment. It describes operating procedures and service instructions, operation, network configuration, technical assistance.

1280
PeakTech 1280
29.03.2026 113 pages

PeakTech® 1280 / 1285 / 1290 / 1325 / 1330 Bedienungsanleitung / Operation manual PC-Oszilloskope mit USB, LAN PC Oscilloscopes with USB, LAN Official user handbook for the PeakTech 1280 Test Equipment. This documentation covers service procedures, interface navigation, installation guides.

Pocket Pro+ Multi 1
Hach Pocket Pro+ Multi 1
05.04.2026 12 pages

User Manual DOC022.53.80398 Pocket Pro™+ Multi 1 1 Official installation manual for the Hach Pocket Pro+ Multi 1 Test Equipment. This documentation details procedures for power requirements, user instructions, system parameters, configuration options.

Plant Vitality and P-Tester
SpectraCrop Plant Vitality and P-Tester
14.03.2026 21 pages

1 User Manual for SpectraCrop Plant Vitality and P-Tester Installation instructions for the SpectraCrop Plant Vitality and P-Tester Test Equipment. It provides information on safety and device overview, configuration options, setup validation.