Keyence LS-5000 Instruction Manual
Text of the manual
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
Contact us: (888) 88-SOURCE | [email protected] | www.artisantg.com
SM
View
Instra
This instruction manual describes the operation and function of the LS-5000 series.
Read this manual carefully to ensure safe use and maximum performance from
your LS-5000 series.
The LS-5000 series uses a semiconductor laser as the light source. Before using
the product, see “Laser Safety Precautions” on page 1 to learn the safe and correct
method of using the LS-5000 series.
Symbols
The following symbols alert you to important messages. Be sure to read these
messages carefully.
Failure to follow instruction may lead to injury. (electric
shock, burn, etc.)
Failure to follow instructions may lead to product damage.
Provides additional information on proper operation.
General Precautions
•
At startup and during operation, be sure to monitor the functions and perfor-
mance of the LS-5000 series.
•
We recommend that you take substantial safety measures to avoid any damage
in the event a problem occurs.
•
Do not open or modify the LS-5000 series or use it in any way other than
described in the specifications.
•
When the LS-5000 series is used in combination with other instruments, func-
tions and performance may be degraded, depending on operating conditions
and the surrounding environment.
•
Do not use the LS-5000 series for the purpose of protecting the human body.
This is a class A (EN55011: EMI standard) product. In a domestic environment this
product may cause radio interference in which case the user may be required to
take adequate measures.
WARNING
CAUTION
Note:
CAUTION
Checking the Contents of the Package
The LS-5000 series includes the following items. Be sure to check that no item is
missing or damaged.
■LS-5501 Package
•
Built-in display type controller: 1
•
Instruction manual: 1
•
AC power cables: 2 1.
■LS-5001 Package
•
Separate type controller: 1
•
Instruction manual: 1
•
Communication cable (OP-26401 + OP-96368): 1
•
LS-VIEWER Software (3.5-inch FD, Instruction manual): 1
■LS-5041/5121 Package
•
Scanning head (Transmitter, receiver and mounting base): 1 2.
•
Mounting brackets: 4
•
ROM board: 1 2.
1.
Two types of AC power cables are provided with the built-in display model LS-5501. One is for 125
VAC and the other is for 250 VAC. Select either according to your local power supply type.
2.
The serial nos. of both units should be identical.
Warranty
See page 125.
Notice
•
No part of this instruction manual may be reprinted or reproduced without the
prior written permission of KEYENCE CORPORATION.
•
KEYENCE assumes no responsibility for the contents of this manual. No liability
is assumed for damages resulting from a program created by customers.
•
The contents of this manual are subject to change without notice.
ii
96M12426
Laser Safety Precautions
1.1
Classification ..........................................................................................2
1.2
Warning Labels ......................................................................................2
1.3
Label Location ........................................................................................3
1.4
Safety Consideration .............................................................................3
1.5
Safety Features Provided with the LS-5000 Series .............................4
1.6
Preparation for Operation .....................................................................6
Chapter 2
Before Using the LS-5000 Series
2.1
System Configuration and Connections .............................................8
2.1.1 System Configuration................................................................................8
2.1.2 Connection Procedure ..............................................................................9
2.2
Names and Functions of Indicators and Switches ...........................12
2.3
Part Names ...........................................................................................13
Chapter 3
Quick Start Reference
3.1
Quick Start Reference .........................................................................16
3.1.1 Procedure for Starting Measurement ......................................................16
Chapter 4
Installation
4.1
Mounting the Scanning Head .............................................................18
4.2
Mounting the Controller ......................................................................19
Chapter 5
Outline of Measurements
5.1
Area/Segment/Edge .............................................................................22
5.2
Normal mode ........................................................................................22
5.2.1 DIA mode ................................................................................................23
5.2.2 T.EDGE (TOP EDGE) mode/B.EDGE (BOTTOM EDGE) mode ............ 23
5.2.3 SEG (m,n) mode .....................................................................................23
5.3
Pitch mode ............................................................................................24
iii
Contents
Normal Mode Screens .........................................................................24
6.2
Initial Screen .........................................................................................27
6.3
Setting Measuring Mode .....................................................................28
6.4
Setting Functions .................................................................................29
1
[HOLD] Hold Function......................................................................30
2
[ZERO] Auto-zero Function .............................................................31
3
[SCREEN] Screen Selection Function .............................................32
4
Limit Setup .......................................................................................35
5
[CALIB] Calibration Setup ................................................................36
6
[PROGRAM] Program Selection Function .......................................38
7
Area Setup .......................................................................................39
8
Calculation Setup.............................................................................41
9
Average ...........................................................................................44
0
Measuring Mode ..............................................................................46
A
Digit Suppression Function ..............................................................54
B
Offset Function ................................................................................55
C
Analog Output Function ...................................................................57
D
I/O Slot Setup ..................................................................................59
E
Inspection ........................................................................................60
F
One-scan Mode ...............................................................................62
G
Program Selection Method Setup ....................................................64
H
Display Unit......................................................................................65
I
Area Check Function .......................................................................66
J
Initialize ............................................................................................67
K
Mode Change ..................................................................................68
Chapter 7
Pitch Mode
7.1
Pitch Mode Screens .............................................................................70
7.2
Initial Screen .........................................................................................71
7.3
Setting Measurement ...........................................................................72
7.4
Setting Functions .................................................................................72
1
Screen Selection Function ...............................................................73
2
Limit Setup .......................................................................................75
3
Program Selection Function ............................................................76
4
Setting Number of Pitches ...............................................................77
5
Average ...........................................................................................79
6
Digit Suppressing Function ..............................................................80
7
Measuring Mode ..............................................................................81
8
Masking ...........................................................................................84
9
Mode Change ..................................................................................85
RS-232C Communication Protocol ....................................................88
8.2
Remote Control Function ....................................................................90
8.3
Command List ......................................................................................97
Chapter 9
Expansion I/O Board
9.1
Control I/O Board ...............................................................................100
9.1.1 Part Names and Pin Assignment ..........................................................100
9.1.2 I/O Terminal Operations........................................................................101
9.1.3 Specifications ........................................................................................102
Chapter 10
Display System Setup
10.1
Display System Setup .....................................................................104
10.1.1 Adjusting Backlight Intensity ...............................................................104
10.1.2 Reversing Display ...............................................................................105
10.1.3 Adjusting Contrast ..............................................................................106
10.1.4 Setting Backlight OFF Time ................................................................107
10.1.5 Adjusting Buzzer Volume....................................................................108
10.1.6 Numeric Keys .....................................................................................109
10.2
Display Hardware Check Function .................................................110
10.3
Replacing Protective Sheet .............................................................111
10.4
Display Panel-lock Function ...........................................................112
Appendices
Appendix A Specifications ........................................................................114
Appendix B Initial Setting ..........................................................................116
Appendix C Troubleshooting Guide .........................................................118
Appendix D Error Messages ......................................................................120
Appendix E Minimum Input Time and Output Response Time .............. 121
Appendix F Dimensions ............................................................................122
WARRANTIES AND DISLAIMERS
125
Laser Safety Precautions
1.1
Classification ........................................................................2
1.2
Warning Labels .....................................................................2
1.3
Label Location ......................................................................3
1.4
Safety Consideration ............................................................ 3
1.5
Safety Features Provided with the LS-5000 Series ........... 4
1.6
Preparation for Operation .................................................... 6
Chapter 1 Laser Safety Precautions
1.1
Classification
1.2
Warning Labels
■LS-5041
Warning label/Aperture label
FDA Class II
IEC Class 2
IEC (French) Classe 2
DIN Klasse 2
■LS-5121
Warning label/Aperture label
FDA Class II
IEC Class 2
IEC (French) Classe 2
DIN Klasse 2
LS-5041
LS-5121
Laser
FDA (CDRH) Part 1040.10
Class II Laser Product
Class
IEC60825-1
Class 2 Laser Product
1
LASER RADIATION-
DO NOT STARE INTO BEAM
SEMICONDUCTOR LASER
WAVELENGTH
OUTPUT
PULSE DURATION
CLASS II LASER PRODUCT
CAUTION
CAUTION
AVOID EXPOSURE
LASER RADIATION
IS EMITTED FROM
THIS APERTURE.
655nm
45µW
14µs
Chapter 1 Laser Safety Precautions
1.3
Label Location
■LS-5041
■LS-5121
The IEC/DIN Warning labels are packed with the scanning head. Stick the Warning
labels on the scanning head or the vicinity where the scanning head is mounted in
order to be easily seen by the operators.
1.4
Safety Consideration
Use of controls or adjustments or the performance of procedures other than those
specified herein may result in hazardous radiation exposure.
The LS-5041 employ a visible semiconductor laser for its light source. The beam is
not harmful to the skin. The possible health hazard is in exposing the eyes to the
laser beam. Damage to the eyes occur if the operator stares directly into the beam.
1
LS-5041T
SCANNING AREA
Aperture
LS-5121T
SCANNING AREA
Aperture
CAUTION
Follow the safety precautions below to ensure operator safety:
•
Operate the LS-5000 series only according to the procedures described in
this instruction manual.
Otherwise, injury may occur due to exposure to the laser beam.
•
Do not disassemble the scanning head.
Laser emission from the LS-5000 series is not automatically stopped if the
scanning head is disassembled. If you disassemble the scanning head for
inspection or repair, you may be exposed to the laser beam. If the LS-5000
series malfunctions, contact KEYENCE immediately.
•
Do not look directly into the laser beam.
Looking directly into the laser beam may result in serious eye injury.
•
Protective enclosure
We recommend that you install a protective enclosure around the scanning
head to prevent any person from getting near the scanning head during opera-
tion.
•
Protective goggles
We recommend that you wear protective goggles when using the LS-5000
series.
•
You must stop all laser emissions before cleaning the laser aperture. Otherwise,
you may be exposed to the laser beam.
•
Be aware of the optical axis of the laser beam.
If you may be exposed to a specularly-reflected or diffused laser beam, provide
an enclosure with reflectivity and thermal characteristics adequate to interrupt
the laser beam.
Install the LS-5041 so that the optical axis of the laser beam will not be at the
same height as your eyes when operating the LS-5000 series.
1.5
Safety Features Provided with the LS-5000 Series
The LS-5000 series comes with the following safety features:
•
Laser emission remote control terminals
Chapter 1 Laser Safety Precautions
1
Rear of the LS-5001
Rear of the LS-5501
Laser emission remote
control input terminal
Laser emission remote
control input terminal
4
WARNING
Chapter 1 Laser Safety Precautions
1
LS-5041T
LS-5041T
Laser ON alarm indicator
•
LASER ON alarm indicator
The scanning head has an LED which indicates that the laser beam is currently
being emitted or is about to start.
Even when you are wearing safety goggles, you can check whether the indicator is
lit or not.
•
Laser beam shield
The LS-5000 series includes a laser beam shield which is to be attached to the
scanning head’s transmitter. Attach this shield when your eyes may be exposed to
the laser beam, for example during operation at the front of the scanning head.
*
FDA safety standards do not require a laser beam shield to be provided with
Class II laser products. However, the shield should be used if necessary.
5
Appearance with the laser
beam shield not attached
Appearance with the laser
beam shield attached
LS-5041T
LS-5041T
Laser beam shield
■LS-5041
■LS-5121
Appearance with the laser
beam shield not attached
Appearance with the laser
beam shield attached
LS-5121T
LS-5121T
Preparation for Operation
■Suppressing noise interference
Be sure to isolate the connection cable from high-voltage or power lines. If the
connection cable is placed in the same conduit as these lines, the LS-5000 series
may malfunction due to noise interference.
■Cooling fan
Do not block the cooling fan at the bottom of the LS-5501. If the cooling fan is
blocked, the LS-5501 may overheat and malfunction.
■Operating environments
•
Use the controller at an ambient temperature of 0°C to 45°C (32 to 113°F), No
freezing.
•
Fluctuations in the ambient temperature cause measurement errors; therefore,
the ambient temperature should be kept constant. If the temperature changes
by 10°C (18°F), the LS-5000 series will take approximately 60 minutes until the
temperature distribution in the unit becomes even.
•
Do not allow any substance which may refract the laser beam, such as water
and oil, to adhere to the scanning head.
*
Blow dust off the protective glass using clean air. Wipe off any remaining dust
using a soft cloth moistened with alcohol.
Note 1: Measurement conditions
When the target oscillates, the measured value may fluctuate. The measurement
accuracy can be improved when the number of averaging measurements is set
higher.
Note 2: Target
When the target shape or luster varies, a measurement error may occur. In this
case, place a standard target in the measuring area and perform the calibration
using the [CALIB] key.
Before Using the LS-5000 Series
2.1
System Configuration and Connections ............................. 8
2.1.1
System Configuration .............................................................. 8
2.1.2
Connection Procedure .............................................................9
2.2
Names and Functions of Indicators and Switches .......... 12
2.3
Part Names ..........................................................................13
Chapter 2 Before Using the LS-5000 Series
8
2
2.1
System Configuration and Connections
The LS-5000 series includes the display unit, controller and scanning head.
This section describes the system configuration and connections of the LS-5000
series.
2.1.1
System Configuration
The LS-5000 series includes the display unit, controller and scanning head. The
controller can be used separately.
The LS-5000 series also offers I/Oboard, as well as a control unit which
incorporates the display unit and controller in a single body.
•
Separate display type
•
Built-in display type
Note: The scanning head and ROM board are calibrated as a pair. Be sure to
combine the units that have the same serial number.
LS-5501
I/O board (LS-B11)
ROM board
LS-5041/5121
Connection cable (option)
LS-C3: 3m
LS-C10: 10 m
LS-C50: 50 m
24 VDC
LS-5001
LS-5041/5121
Connection cable (option)
LS-C3: 3m
LS-C10: 10 m
LS-C50: 50 m
ROM
board
Expansion slots
Power
supply
I/O board (LS-B11)
Personal computer
LS-VIEWER
operating software
for Windows 95
Chapter 2 Before Using the LS-5000 Series
9
2
CAUTION
2.1.2
Connection Procedure
Connecting the Scanning Head
Be sure to turn the power off before connecting the scanning head.
■Connection of ROM Board
1. Remove the frame cover.
2. Insert the ROM board.
Note: Insert the ROM board into HEAD 1 first.
3. Tighten the screws.
4. Re-attach the frame cover.
Frame cover
Frame cover
LS-5501
LS-5001
LS-5001
Screws
Screws
LS-5501
LS-5001
Frame cover
Frame cover
LS-5501
LS-5001
LS-5501
Chapter 2 Before Using the LS-5000 Series
10
2
■Connecting Transmitter and Receiver
1. Connect the cable between the transmitter and receiver.
Use the extension cable if necessary.
Extension cable between transmitter and receiver: OP-26540 (3 m)
OP-26816 (10 m)
2. Connect the cable between the transmitter and receiver to the scanning head
and ROM board. (This cable is optional.)
Connection cable
LS-C3
3 m
LS-C10
10 m
LS-C50
50 m
Transmitter
Receiver
Transmitter
Receiver
LS-C3 (3 m)
To ROM board
Chapter 2 Before Using the LS-5000 Series
11
2
Connecting I/O Board
Be sure to turn the power off before connecting the I/O board.
1. Remove the frame cover.
2. Insert the I/O board.
Note: Use the slot 1 first. When the slot 1 is used, use the slot 2.
3. Tighten the screws.
4. Re-attach the frame cover.
CAUTION
LS-5501
LS-5001
Frame cover
Frame cover
LS-5501
LS-5001
LS-5501
LS-5001
Screws
Screws
LS-5501
LS-5001
Chapter 2 Before Using the LS-5000 Series
12
2
2.2
Names and Functions of Indicators and Switches
This section describes the names and functions of the indicators and switches.
■Names and Functions of Indicators and Switches
Display
Name
Description
Menu button
Used to move to each function’s setup screen.
Setup/Select
Used to set values or select settings.
button
Select button
Used to select settings or programs.
Screen Select
When you press the [Screen Select] button, you
button
will move to the screen indicated on the button.
In the example on the left, you will move to the
DISPLAY DATA screen.
Numeric keys
Used to set values.
[ENTER] key: Used to accept the setting.
[ESCAPE] key: Used to exit from the numeric keys
screen.
[CANCEL] key: Used to reset the preset value to
zero.
Sign key: Used to change the sign.
[▲] [ ] keys: Used to move between setting
items.
DISPLAY
DATA
LIMIT
SETUP
7
8
9
4
5
6
1
2
3
0
•
–
ESCAPE
CANCEL
ENTER
■Input Procedure Using Numeric Keys
Example: Enter “-5.0000”.
5
•
0
0
0
0
–
ESCAPE
ENTER
▲
Chapter 2 Before Using the LS-5000 Series
13
2
2.3
Part Names
This section describes the part names of each model.
LS-5001 (Separate display type)
Front
1 I/O connector (LS-B11)
2 Analog output BNC connector (LS-B11)
3 Scanning head connecting port
4 DIP switch
5 Laser emission control input terminal
6 Program selection input terminal
7 Power supply terminal (24 VDC)
LS-5501 (Built-in display type)
Front
Rear
1 Measured value display and function setup/operating unit
2 I/O connector (LS-B11)
3 Analog output BNC connector (LS-B11)
4 Scanning head connecting port
5 DIP switch
6 Laser emission control input terminal
7 Program selection input terminal
8 Power supply switch
9 Power supply input
0 Fuse holder (250 V, 3.15 A)
A Expansion slot 1 for I/O board
B Expansion slot 2 for I/O board
7
1
2
3
4
2
5
6
1
10
8
9
2
3
3
4
5
12
11
7
6
Chapter 2 Before Using the LS-5000 Series
14
2
LS-5041/5121 (Scanning head)
1 Laser ON alarm indicator
2 Transmitter (T)
3 Laser emission aperture
4 Receiver (R)
5 Connecting cable between scanning head and controller
6 Connecting cable between transmitter and receiver
7 Scanning head mounting frame
1
2
3
4
5
6
7
6
Quick Start Reference
3.1
Quick Start Reference ........................................................ 16
3.1.1
Procedure for Starting Measurement..................................... 16
Chapter 3 Quick Start Reference
16
3
3.1
Quick Start Reference
This section describes the procedures for starting measurement for trial operation.
3.1.1
Procedure for Starting Measurement
Before changing the measuring mode or the number of averaging measurements,
read this instruction manual thoroughly for the correct settings.
For setting items, see the table of contents.
The following is reference page numbers for typical operations.
• Changing the DIA mode to EDGE mode ...............................................p.39, 40
• Changing the number of averaging measurements...............................p.44, 45
• Changing the measuring mode...........................................................p.46 to 51
• Simultaneous measurement ........................................................................p.32
• (X + Y)/2 measurement using two scanning heads ...............................p.41, 42
Connect the controller and scanning head.
Turn the power on.
Align the optical axis of the transmitter and
receiver.
The 5001 series starts laser emission in
approximately 5 seconds, at which time the
measurement begins.
Place a target in the measuring area.
The measured value is soon displayed.
For information on the connection
procedure, see p. 8.
• When the transmitter and receiver are
fixed to the scanning head mounting
frame, optical axis alignment is not
necessary.
• For information on the scanning head
mounting allowance, see p. 18.
For information on checking the optical
axis, see p. 60 and 61.
For information on the measuring area,
see p. 115.
The factory setting for the number of
averaging measurements is 768 for DIA
mode.
▲
▲
▲
▲
▲
Mounting the Scanning Head ............................................ 18
4.2
Mounting the Controller .....................................................19
Chapter 4 Installation
18
4
4.1
Mounting the Scanning Head
The LS-5000 series comes with the transmitter and receiver fixed to the scanning
head mounting frame. To use the LS-5000 series with the transmitter and receiver
removed from the mounting frame, mount the scanning head so that the following
specifications are met. This will eliminate measurement errors caused by optical
axis misalignment.
Allowance for Mounting the Scanning Head
■ Horizontal deviation of transmitter and receiver positions
■ Inclination of transmitter and receiver
Note: For information on the optical axis checking function, see “Head Inspection”
on p. 60.
Transmitter
Receiver
Transmitter
Receiver
Within ±1 mm
Within ±1 mm
Transmitter
Receiver
Transmitter
Receiver
Within ±1 mm
Within ±1 mm
Receiver
Receiver
Within ±0.25°
Within ±0.25°
Within ±0.25°
Within ±0.25°
Transmitter
Transmitter
Receiver
Transmitter
Transmitter
Receiver
* Values in parentheses are for the LS-5121.
Chapter 4 Installation
4
4.2
Mounting the Controller
This section describes how to mount the controller (LS-5001).
Mounting the LS-5001
The LS-5001 can be mounted to a DIN rail.
Hook the upper claw first, and then press the controller against the DIN rail until it
clicks.
DIN rail
Mounting the Scanning Head Front Protection Cover (For LS-5121)
Application example of front protection cover
The LS-5121 transmitter and receiver come with a protection cover for the scan-
ning head.
Mount the cover as shown in order to prevent the front glass of the scanning head
from being scratched or broken.
Receiver
LS-5121T
SCANNING AREA
LS-5121R
SCANNING AREA
Transmitter
Outline of Measurements
5.1
Area/Segment/Edge ............................................................ 22
5.2
Normal Mode .......................................................................22
5.2.1
DIA Mode ...............................................................................23
5.2.2
T.EDGE (TOP EDGE) Mode /
B.EDGE (BOTTOM EDGE) Mode ......................................... 23
5.2.3
SEG (m,n) Mode .................................................................... 23
5.3
Pitch Mode ...........................................................................24
Chapter 5 Outline of Measurements
22
5
5.1
Area/Segment/Edge
When a target is placed in the measuring area, there are areas where the laser
beam is received (laser beam enters the receiver), and where the laser beam is
interrupted by the target (shadow of the target is projected on the receiver). The
border between the light and dark areas is called “EDGE”. Each section divided by
the edge is called a “SEGMENT”. The measurement "AREA" is determined by two
edges and includes all "SEGMENTS" between these two edges.
*
The edge number is counted in the laser scanning direction starting at T.EDGE
(top edge).
Note: EDGE 0
The position of the photodiode for synchronization is called “EDGE 0”.
EDGE 0 can be used as a reference point during roller oscillation measurement or
sheet edge control. (No reference edge is required.)
Example: Roller oscillation measurement
5.2
Normal Mode ➮ For the setting procedure, see p. 39.
The LS-5000 series has two measuring modes; NORMAL and PITCH. NORMAL
mode provides four types of measurement3: “DIA”, “T.EDGE (Top Edge)”,
“B.EDGE (Bottom Edge)” and “SEG(m,n)”.
The function of each mode is described below. Select the mode that suits your
measurement condition.
Edge 0
Edge 1
Edge 2
Edge 3
Edge 4
Edge 5 (n-1)
Edge 6 (n)
Photodiode for synchronization
Laser
scanning
direction
Target
Transmitter
Receiver
Photodiode for synchronization
Transmitter
Receiver
Roller
Rotating
This width can be
measured when
SEG(m,n) is set to (0,2) in
Normal mode.
DIA mode
Measurement of outer diameter
of rod or electric wire
T.EDGE/B.EDGE modes
Measurement of gap
between rollers or position
of target
edge
SEG(m,n) mode
Setting the measurement
position to measure inner
diameter using
a bearing
Chapter 5 Outline of Measurements
23
5
5.2.1
DIA Mode
Example: Outer diameter measurement using a rod or transparent object
The width between the lower edge of the first light segment and the top edge of the
last light segment is measured.
•
When one target is measured
•
When several targets are measured
5.2.2
T.EDGE (TOP EDGE) Mode / B.EDGE (BOTTOM EDGE) Mode
Example: Measurement of a gap between rollers
T.EDGE: Measures the width of the first light segment.
B.EDGE: Measures the width of the last light segment.
5.2.3
SEG (m,n) Mode
Example: Inner diameter measurement using a bearing
When two edges are specified, the width between these edges is measured.
*
(m,n) indicates any number between 0 and 254. “m” should be smaller than “n”.
Note: DIA mode
Since DIA mode is basically intended for outer diameter measurement of a rod,
transparent tube or other round surface, the measurement error due to the round
surface is calibrated.
To perform outer diameter measurement of a round target, select DIA mode.
Photodiode for synchronization
Laser
scanning
direction
Target
Measured
width
Transmitter
Receiver
Photodiode for synchronization
Target
Measured
width
Transmitter
Receiver
Photodiode for synchronization
Target
The T.EDGE mode
measures this width.
The B.EDGE mode
measures this width.
Transmitter
Receiver
Photodiode for synchronization
Target
Both the T.EDGE and B.EDGE
modes measure this width.
Transmitter
Receiver
Photodiode for synchronization
Target
This width is measured
when SEG(3,4) is set.
Transmitter
Receiver
0
1
2
3
4 5
6
Chapter 5 Outline of Measurements
24
5
5.3
Pitch Mode ➮ For the setting procedure, see p. 72.
Pitch mode enables pitch measurement using connector pins or IC leads.
This mode measures each center-to-center pitch, and displays the maximum and
minimum values.
Note 1: When Pitch mode is selected, only one measurement can be performed
with one scanning head.
Note 2: When Pitch mode is selected, the comparator output is activated as shown
below:
HI3 = Alarm output
HI2 = Disabled
HI1 = Output when the measured value exceeds the upper/lower limit.
GO = Output when the measured value is within the upper/lower limit.
LO1: Disabled
LO2: Disabled
LO3: Disabled
The analog output and RS-232C output are activated as shown below.
Analog output: Held at +10V.
RS-232C output: Output according to the command. ➮ See p. 97.
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
OK
Max
Min
0.5010
0.4990
HEAD2
OK
Max
Min
0.6010
0.5990
HEAD3
OK
Max
Min
0.7020
0.6980
HEAD4
OK
Max
Min
0.8020
0.7980
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
DISPLAY
DATA
Pitch
Optical axis
Normal Mode Screens ........................................................ 26
6.2
Initial Screen .......................................................................27
6.3
Setting Measuring Mode .................................................... 28
6.4
Setting Functions ...............................................................29
1
[HOLD] Hold Function .................................................... 30
2
[ZERO] Auto-zero Function ............................................ 31
3
[SCREEN] Screen Selection Function ........................... 32
4
Limit Setup .....................................................................35
5
[CALIB] Calibration Setup ..............................................36
6
[PROGRAM] Program Selection Function ..................... 38
7
Area Setup .....................................................................39
8
Calculation Setup ...........................................................41
9
Average ..........................................................................44
0
Measuring Mode.............................................................46
A
Digit Suppression Function ............................................ 54
B
Offset Function ...............................................................55
C
Analog Output Function.................................................. 57
D
I/O Slot Setup .................................................................59
E
Inspection .......................................................................60
F
One-scan Mode.............................................................. 62
G
Program Selection Method Setup .................................. 64
H
Display Unit .................................................................... 65
I
Area Check Function ...................................................... 66
J
Initialize ..........................................................................67
K
Mode Change .................................................................68
Chapter 6 Normal Mode
26
6
6.1
Normal Mode Screens
LASER ON
SCREEN
NOR
MAL
P. 1
DISPLAY DATA
DISPLAY DATA
DISPLAY GRAPH
DISPLAY GRAPH
ON
OUT1
SET
SET
OFF
OUT2
OUT1
OFF
OUT3
OFF
OUT4
LASER ON
DISPLAY GRAPH
OUT1
NOR
MAL
P. 1
SETUP
SCREEN
40.0000
0.0000
DATA:
25.77110
AREA
OUT1
OUT4
OUTPUT
INSPECT
UTILITY
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OUT1
HI3
HI1
20.0000
LO1
15.0000
OFF
OFF
ZERO
HOLD
SCREEN
SCREEN
DISPLAY
DATA
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
CALIB
OPTIONS
54.21595
LASER ON
SELECT OUTPUT
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SET UP
LIMIT
SET UP
PROGRAM
CALIB
OPTIONS
OUT1
OUT2
OUT3
OUT4
Select Output No. to set the limits.
LASER ON
AREA SETUP
NOR
MAL
P. 1
DIA
HEAD1
( 2, 3)
ESC
HELP
SET
HEAD No.
EDGE No.
A1
SEGMENT
DIA
HEAD2
( 2, 3)
SET
HEAD No.
EDGE No.
A2
SEGMENT
SEGMENT
SEGMENT
DIA
HEAD3
( 2, 3)
SET
HEAD No.
EDGE No.
A3
DIA
HEAD4
( 2, 3)
SET
HEAD No.
EDGE No.
A4
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
HEAD1
HEAD4
LASER ON
CALIBRATE AREA
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
CALIB
CALIB
PROGRAM
OPTIONS
OPTIONS
AREA1
AREA2
AREA3
AREA4
Select Area No. to calibrate.
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
LASER ON
I/O SLOT SETUP
NOR
MAL
P. 1
I/O
OUT1
OUT2
OUT1
OUT2
SLOT1
CH1
I/O
I/O
I/O
CH2
SLOT2
CH1
CH2
ESC
I/O SLOT SETUP
LASER ON
SELECT PROGRAM No.
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
CALIB
OPTIONS
Selected program No.
1
5
8
7
6
4
2
3
1
13
16
15
14
12
10
11
9
LASER ON
INSPECT
NOR
MAL
P. 1
HEAD1
HEAD2
HEAD3
HEAD4
ESC
Select Head to inspect.
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: OK
OPTICAL AXIS
ESC
NOR
MAL
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
UTILITY
NOR
MAL
P. 1
AREA CHECK
INITIALIZE
ON
PANEL
mm
ONE-SCAN MODE
PROGRAM SELECT
DISPLAY UNIT
ESC
DISPLAY DATA screen
SCREEN SELECT screen
DISPLAY GRAPH screen
LIMIT SETUP screen
AREA SETUP screen
OUTPUT MODE screen
CALIBRATE screen
OUTPUT MODE screen
I/O SLOT SETUP screen
SELECT PROGRAM NO.
screen
INSPECT screen
HEAD INSPECT screen
OPTIONS screen
UTILITY screen
➮ See p.30.
➮ See p. 33.
➮ See p. 33.
➮ See p.35.
➮ See p.39.
➮ See p.41-58.
➮ See p.36.
➮ See p.41.
➮ See p.59.
➮ See p.38.
➮ See p.60.
➮ See p.60.
➮ See p.39.
➮ See p.62-68.
Chapter 6 Normal Mode
27
6
6.2
Initial Screen
Laser ON/OFF
status
Screen title
Measuring
mode
Program No.
Hold switch
Screen
selecting
switch
To the
OPTION S
screen
To the
SELECT
PROGRAM
NO. screen
To the CALIB
screen
To the LIMIT
SETUP screen
To the DISPLAY
DATA screen
Auto-zero switch
Displays the measured
value, comparator output
and upper/lower limits
(HI1, LO1) for OUT1.
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OUT1
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT2
54.21595
HI1
20.0000
LO1
15.0000
HI3
OFF
OFF
ZERO
HOLD
OUT3
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT4
54.21595
HI1
20.0000
LO1
15.0000
HI3
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
Chapter 6 Normal Mode
28
6
6.3
Setting Measuring Mode
Setting Scanning Head and Measurement
1. Setting Measuring Area
The LS-5000 series can simultaneously perform four measurements and outputs
with one scanning head, and different measurements and outputs with four scan-
ning heads. (➮ See note.)
The place for which the measurement condition is set is called the “measuring
area” (A1 to A4), where the scanning head number and measuring mode can be
set.
Note: The LS-5002 and 5502 can only control a single scanning head.
2. Setting Output Mode
The LS-5000 series can accept measurement data from multiple scanning heads
and perform calculations on the data for displaying and outputting the comparator
result.
Using the preset measuring area (A1 to A4), you can set various calculation and
measuring modes, as well as the number of averaging measurements as shown
below.
LASER ON
AREA SETUP
NOR
MAL
P. 1
DIA
HEAD1
( 2, 3)
ESC
HELP
SET
HEAD No.
EDGE No.
A1
SEGMENT
SEGMENT
SEGMENT
SEGMENT
DIA
HEAD2
( 2, 3)
SET
HEAD No.
EDGE No.
A2
DIA
HEAD1
( 2, 3)
SET
HEAD No.
EDGE No.
A3
DIA
HEAD1
( 2, 3)
SET
HEAD No.
EDGE No.
A4
AREA
OPTIONS
A3
A4
A1
A2
DIA
HEAD2
( 2, 3)
SET
HEAD No.
EDGE No.
A2
SEGMENT
Set the measurement mode
[DIA, T.EDGE, B.EDGE, SEG(m,n)].
(AREA SETUP
screen)
A2 (Measuring area 2)
Set the scanning
head number (1 to 4).
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
OUTPUT
OPTIONS
Digit
Calculation
No. of Averaging
Measurements
Measurement
mode
Chapter 6 Normal Mode
29
6
6.4
Setting Functions
Names and functions
Tag/Button
Function
Description
Reference
page
DISPLAY
HOLD
Hold
A measured value can be held or reset.
30
DATA
ZERO
Auto-zero
A measured value can be instantaneously reset to “0.000”.
31
SCREEN
Screen Selection
The DISPLAY DATA screen or DISPLAY GRAPH screen
32 to 34
can be selected.
LIMIT SETUP
Limit Setup
7 level tolerance limits can be set for each output.
35
CALIB
Calibration Setup
Minute measurement fluctuations caused by a change in the
36
target surface condition or target inclination can be corrected.
PROGRAM
Program Selection
Measurement data is stored and called as programs.
38
AREA
Area Setup
DIA, T.EDGE, B.EDGE or SEG(m,n) can be selected.
39
OUTPUT
Calculation Setup
Calculation can be performed with each measuring area
41
(A1 to A4).
Average
Measurement results can be averaged.
44
M. Mode
Nine measuring modes are provided.
46 to 53
Offset
Any value can be added to or subtracted from the displayed
55
value.
Digit
Sets the number of digits after the decimal point.
54
Analog Output
An analog voltage (within ±10 V) proportional to the displayed
57
value can be output.
I/O Slot Setup
Expansion I/O boards can be set.
59
INSPECT
Inspect
The scanning head conditions (optical axis, intensity) can
60
be checked.
UTILITY
One-Scan Function
Data obtained with only one surface of the 12-surface polygon
62
mirror becomes effective.
Program Selection
The program selection method (front panel or rear terminals)
64
can be selected.
Display Unit
The display units can be selected (“mm” or “inch”).
65
Area Check
The number of edges in the measuring area can be
66
checked.
Initialize
All settings are reset to the initial values.
67
Mode Change
Normal mode or Pitch mode can be selected.
68
OPTIONS
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OFF
OFF
ZERO
HOLD
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
Button
Tag
Chapter 6 Normal Mode
30
6
1
1
1
1
1 [HOLD] Hold Function
The hold function allows the displayed value and output value to be held or reset
regardless of the measuring mode.
■Setting Procedure
1. Select the DISPLAY DATA screen.
Press the [DISPLAY DATA] button. The screen shown below is displayed.
2. Set the hold function.
Press the [HOLD OFF] button. [HOLD OFF] is changed to [HOLD ON].
Note: The hold function cannot be set separately for each output from this screen.
To set this function separately for each output, send the hold signal from the
control I/O board (Option). (Short-circuit the Tim input terminal and the GND
terminal.)
DISPLAY
DATA
OFF
HOLD
HOLD
ON
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OUT1
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT2
54.21595
HI1
20.0000
LO1
15.0000
HI3
OFF
OFF
ZERO
HOLD
OUT3
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT4
54.21595
HI1
20.0000
LO1
15.0000
HI3
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OUT1
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT2
54.21595
HI1
20.0000
LO1
15.0000
HI3
OFF
ON
ZERO
HOLD
OUT3
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT4
54.21595
HI1
20.0000
LO1
15.0000
HI3
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
Chapter 6 Normal Mode
31
6
2
2
2
2
2 [ZERO] Auto-zero Function
The auto-zero function can instantaneously reset the displayed value to “0.0000”.
This function simplifies zero-point adjustment when targets are changed over.
■Setting Procedure
1. Select the DISPLAY DATA screen.
Press the [DISPLAY DATA] button. The screen below is displayed.
2. Set the auto-zero function.
Press the [ZERO OFF] button. [ZERO OFF] is changed to [ZERO ON].
The following two methods will also activate the auto-zero input.
•
Short-circuit the auto-zero input terminal and the GND terminal of the control I/O
board (Option).
The auto-zero function can be set separately for each output.
•
Send a command through the RS-232C board from external equipment such as
a computer.
You can reset the auto-zero function by sending the command. ➮ See p. 93.
Note 1: The auto-zero function cannot be reset with the control I/O input.
Note 2: When the displayed value is “- - - - -”, the auto-zero function cannot be
activated.
Note 3: When the auto-zero function is activated from the front panel, all outputs
are simultaneously reset to “0.0000”.
DISPLAY
DATA
OFF
ZERO
ZERO
ON
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OUT1
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT2
54.21595
HI1
20.0000
LO1
15.0000
HI3
OFF
OFF
ZERO
HOLD
OUT3
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT4
54.21595
HI1
20.0000
LO1
15.0000
HI3
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OUT1
0.00000
0.00000
0.00000
0.00000
HI1
20.0000
LO1
15.0000
LO1
OUT2
HI1
20.0000
LO1
15.0000
LO1
OFF
ON
ZERO
HOLD
OUT3
HI1
20.0000
LO1
15.0000
LO1
OUT4
HI1
20.0000
LO1
15.0000
LO1
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
Chapter 6 Normal Mode
32
6
3
3
3
3
3 [SCREEN] Screen Selection Function
The screen selection function allows you to select the DISPLAY DATA screen (1 to
4 data displays) or the DISPLAY GRAPH screen.
Example 1: When several scanning heads are used
Example 2: Measurement of wire’s outer diameter
■Setting Procedure
1. Select the DISPLAY DATA screen.
Press the [DISPLAY DATA] button. The screen shown below is displayed.
2. Select the SCREEN SELECT screen.
Press the [SCREEN] button.
LASER ON
DISPLAY DATA
NOR
MAL
P. 1
OUT1
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT2
54.21595
HI1
20.0000
LO1
15.0000
HI3
OFF
OFF
ZERO
HOLD
OUT3
54.21595
HI1
20.0000
LO1
15.0000
HI3
OUT4
54.21595
HI1
20.0000
LO1
15.0000
HI3
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
DISPLAY
DATA
SCREEN
DISPLAY DATA
DISPLAY GRAPH
or
OUT1 54.21595 H13 OUT3 5421595 H13
HI
LO
OUT2 54.21595 H13 OUT4 5421595 H13
HI
LO
HI
LO
HI
LO
200000
200000
200000
200000
200000
200000
200000
200000
Chapter 6 Normal Mode
33
6
3. Set the output to be displayed. (➮ For setting outputs, see p.41.)
Turn ON the output to be displayed.
If an output is not to be displayed, press the [ON] button once to turn it OFF.
4. Return to the DISPLAY DATA screen.
Press the [DISPLAY DATA] button to return to the DISPLAY DATA screen.
■Setting Procedure
1. Perform steps 1 and 2 described on the previous page to go to the SCREEN
SELECT screen shown below.
2. Select “DISPLAY GRAPH”.
Select the output to be graphically displayed.
OUT1 to OUT4 are switched in the above order.
Press the [DISPLAY GRAPH] button.
3. Perform “GRAPH SETUP”.
Press the [SETUP] button.
OUT1
OUT2
OUT3
OUT4
LASER ON
SCREEN
NOR
MAL
P. 1
DISPLAY DATA
DISPLAY GRAPH
ON
OUT1
SET
SET
OFF
OUT2
OUT1
OFF
OUT3
OFF
OUT4
LASER ON
DISPLAY GRAPH
OUT1
NOR
MAL
P. 1
SETUP
SCREEN
40.0000
0.0000
DATA:
25.77110
LASER ON
SCREEN
NOR
MAL
P. 1
DISPLAY DATA
DISPLAY GRAPH
ON
OUT1
SET
SET
OFF
OUT2
OUT1
OFF
OUT3
OFF
OUT4
Chapter 6 Normal Mode
34
6
4. Set the range of GRAPH display.
Perform “RANGE SETUP”. Press the [RANGE] button.
Select the item from MAX or MIN using the [▲] [ ] arrow keys.
Enter a value using the numeric keys and press [ENTER].
5. Perform “TIME SETUP”.
Press the [TIME] button. Select the item from SAMPLING FREQ or NO. OF
DATA using the [▲] [ ] arrow keys. Enter a value using the numeric keys and
press [ENTER].
Note 1: Range Setup
The maximum and minimum range setup values are as follows:
Max.: 999.9999 (9.99999)
Min.: -99.9999 (-0.99999)
*
Values in ( ) are the maximum and minimum values displayed in inches.
When the displayed value exceeds the above range, “OVER” is displayed and the
entered value cannot be accepted.
Note 2: Time Setup
The maximum and minimum values for the sampling frequency and the number of
displayed data are as follows:
Sampling frequency
Max.: 30000 x 0.1 s (3000 s) Min.: 1 (0.1 s)
Number of displayed data
Max.: 600 Min.: 2
When the sampling frequency or the number of displayed data exceeds the above
range, “OVER” is displayed and the entered value cannot be accepted.
Note 3: The above maximum and minimum values are independent of tolerance
limits.
LASER ON
SETUP
OUT1
NOR
MAL
P. 1
RANGE
TIME
MAX:
MIN:
40.0000
0.0000
SAMPLING
FREQ:
NO. OF DATA:
1 X 0.1S
100
▲
▲
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The
value returns to the previous value.
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The
value returns to the previous value.
SETUP
OUT2
LASER ON
NOR
MAL
P. 1
8
7
5
6
4
2
3
1
0
9
ENTER
CANCEL
ESCAPE
MAX:
40.0000
MIN:
SAMPLING
FREQ:
NO. OF DATA:
0.0000
1 X 0.
100
SETUP
OUT1
LASER ON
NOR
MAL
P. 1
8
7
5
6
4
2
3
1
.
-
0
9
ENTER
CANCEL
ESCAPE
MAX:
40.0000
MIN:
SAMPLING
FREQ:
NO. OF DATA:
0.0000
1 X 0.
100
Chapter 6 Normal Mode
35
6
4
4
4
4
4 Limit Setup
7-level-tolerance-limits can be set separately for four outputs. (➮ See p.41 for
setting output.)
■Setting Procedure
1. Select the LIMIT SETUP screen.
Press the [LIMIT SETUP] button. The screen shown below is displayed.
2. Set tolerance limits.
Press the button corresponding to the output for which you wish to set tolerance
limits.
Select a desired tolerance limit using the [▲]/[ ] arrow keys.
Enter a value using the numeric keys, and press [ENTER].
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The value returns to the previous value.
Note 1: When a measured value exceeds the tolerance range, the measured value
is displayed in reverse. The differentiation result corresponding to the tolerance
limits is output from the display unit and the control I/O (option) board.
Note 2: Tolerance limits must conform to the following condition:
HI3 > HI2 > HI1 > LO3 > LO2 > LO1
Otherwise, the tolerance value cannot be entered. (The “ERR” message appears
on the display and the entered value cannot be accepted.)
Note 3: The maximum and minimum tolerance limit values are as follows:
Max.: 999.9999 (9.99999)
Min.: -99.9999 (-0.99999)
* Values in ( ) are the maximum and minimum values displayed in inches.
OUT1
• • •
OUT4
LIMIT
SETUP
LASER ON
SELECT OUTPUT
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
OUT1
OUT2
OUT3
OUT4
Select Output No. to set the limits.
LIMIT SETUP
OUT1
LASER ON
NOR
MAL
P. 1
8
7
5
6
4
2
3
1
.
-
0
9
ENTER
CANCEL
ESCAPE
HI3
30.0000
HI2
25.0000
HI3
20.0000
LO1
15.0000
LO2
10.0000
LO3
5.0000
▲
Chapter 6 Normal Mode
36
6
5
5
5
5
5 [CALIB] Calibration Setup
Minute measurement fluctuations caused by a change in the target surface condi-
tion or target inclination can be corrected with each AREA. (➮ See p.39 for setting
AREA.)
■Setting Procedure
1. Select the CALIBRATE AREA screen.
Press the [CALIB] button. The screen shown below is displayed.
2. Press the button corresponding to the area for which you wish to perform
calibration.
Press the [RESET] button to reset the calibration. The calibration value is reset
to the factory setting.
Press the [CALIBRATE] button to go to the CALIBRATE screen.
3. Insert sample workpiece 1 to check the measured value.
Enter the value of sample workpiece 1 using the numeric keys, and accept the
value by pressing the [ENTER] button.
AREA1
CALIB
• • •
AREA4
CALIBRATE
AREA2
LASER ON
NOR
MAL
P. 1
DATA
54.21595
ESC
CALIBRATE
RESET
LASER ON
CALIBRATE AREA
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA1
AREA2
AREA3
AREA4
Select Segment No. to calibrate.
CALIBRATE
AREA1
LASER ON
NOR
MAL
P. 1
8
7
5
6
4
2
3
1
.
0
9
ENTER
CANCEL
ESCAPE
TARGET1
0.0000
DATA
54.21595
TARGET1
0.0000
Enter calibration
values for targets
1 and 2, and press
OK.
OK
Chapter 6 Normal Mode
37
6
4. Insert sample workpiece 2 to check the measured value.
Enter the value of sample workpiece 2 using the numeric keys, and accept the
value by pressing the [ENTER] button.
When you press the [OK] button, the calibration is performed and a message
regarding the calibration result is displayed.
Input Conditions
Workpiece 1 < Workpiece 2
0.5 ≤ Span ≤ 2
If the above conditions are not satisfied, the “Calibration Error” message is
displayed.
When the above conditions are satisfied, the “Calibration OK” message is
displayed.
Chapter 6 Normal Mode
38
6
6
6
6
6
6 [PROGRAM] Program Selection Function
The LS-5000 series can store all measurement conditions as a program. Up to 16
programs can be stored and loaded easily.
■ Setting Procedure
1. Select the SELECT PROGRAM NO. screen.
Press the [PROGRAM] button.
2. Select a program number.
Press the button corresponding to the program number to be loaded.
Note 1: When the program selection method is set to the rear terminals, the
program number cannot be switched on the front panel. ➮ See p. 63.
Note 2: To switch a program number using the rear terminals, change the combi-
nation of the following four terminals and GND terminal.
ON: This terminal and the GND terminal are short-circuited.
OFF: This terminal is open.
Note 3: The system setup for the display unit (➮ see p. 104) cannot be stored by
the program function.
Terminal No.
Program No.
P1
P2
P3
P4
1
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
4
ON
ON
OFF
OFF
5
OFF
OFF
ON
OFF
6
ON
OFF
ON
OFF
7
OFF
ON
ON
OFF
8
ON
ON
ON
OFF
9
OFF
OFF
OFF
ON
10
ON
OFF
OFF
ON
11
OFF
ON
OFF
ON
12
ON
ON
OFF
ON
13
OFF
OFF
ON
ON
14
ON
OFF
ON
ON
15
OFF
ON
ON
ON
16
ON
ON
ON
ON
P1
P2
P3
P4
GND
• • •
PROGRAM
1
16
LASER ON
SELECT PROGRAM No.
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
Selected program No.
1
5
8
7
6
4
2
3
1
13
16
15
14
12
10
11
9
Chapter 6 Normal Mode
39
6
7
7
7
7
7 Area Setup
The scanning head (Head 1 to Head 4) and measuring mode (DIA, T.EDGE,
B.EDGE, SEG(m,n))can be selected for a measuring area. Up to 4 areas can be
set at the same time. (➮ see p. 22 for Area.)
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the AREA SETUP screen.
Press the [AREA] button.
3. Set the scanning head number.
When you press the [HEAD No.] button, the scanning head number is switched
in the following order.
4. Set the segment.
When you press the [SEGMENT] button, the segment is switched in the follow-
ing order.
Note 1: The edge number setting is effective only when “SEG” is selected as the
SEGMENT.
Note 2: When either of DIA, T.EDGE, or B.EDGE is selected for a scanning head,
SEG cannot be selected for the same head. Also, when SEG is selected, DIA,
T.EDGE, and B.EDGE cannot be selected for the same head.
Note 3: When only one scanning head is connected, the head number remains
“HEAD 1” even if the head number button is pressed.
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
AREA SETUP
NOR
MAL
P. 1
DIA
HEAD1
( 2, 3)
ESC
HELP
SET
HEAD No.
EDGE No.
A1
SEGMENT
SEGMENT
SEGMENT
SEGMENT
DIA
HEAD2
( 2, 3)
SET
HEAD No.
EDGE No.
A2
DIA
HEAD3
( 2, 3)
SET
HEAD No.
EDGE No.
A3
DIA
HEAD4
( 2, 3)
SET
HEAD No.
EDGE No.
A4
HEAD1
HEAD2
HEAD3
HEAD4
DIA
T. EDGE
B. EDGE
SEG
OPTIONS
AREA
Chapter 6 Normal Mode
40
6
■Procedure for Setting Edge Number (Only when SEG is selected.)
1. Select the AREA SETUP screen.
Perform steps 1 and 2 described on the previous page to go to the screen
shown below.
2. Set the EDGE number.
Press the [SET] button corresponding to the area for which you wish to set the
edge number.
You can enter a value in the space indicated by the dotted line
.
Enter a value using the numeric keys, and press [ENTER] key.
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The value returns to the previous value.
Note 1: The edge number (m,n) must conform to the condition: m < n.
When “m” is larger than “n”, the “ERR” message is displayed and the entered value
cannot be accepted.
Note 2: When you press the [HELP] button, descriptions about the measuring mode
(DIA, T.EDGE/B.EDGE and SEG) are displayed on the screen.
LASER ON
AREA SETUP
NOR
MAL
P. 1
SEG
HEAD1
( 2, 3)
ESC
HELP
SET
HEAD No.
SEGMENT
SEGMENT
SEGMENT
SEGMENT
EDGE No.
A1
SEG
HEAD1
( 2, 3)
SET
HEAD No.
EDGE No.
A2
SEG
HEAD1
( 2, 3)
SET
HEAD No.
EDGE No.
A3
SEG
HEAD1
( 2, 3)
SET
HEAD No.
EDGE No.
A4
LASER ON
AREA SETUP
NOR
MAL
P. 1
SEG
HEAD1
( 2 , 3)
SET
HEAD No.
EDGE No.
A1
SEGMENT
SEGMENT
SEG
HEAD1
( 2, 3)
SET
HEAD No.
EDGE No.
A2
8
7
5
6
4
2
3
1
.
-
0
9
ENTER
CANCEL
ESCAPE
( 2 , 3)
LASER ON
AREA SETUP
NOR
MAL
P. 1
SEG
HEAD1
SET
HEAD No.
EDGE No.
A3
SEGMENT
SEGMENT
SEG
HEAD1
( 2, 3)
SET
HEAD No.
EDGE No.
A4
8
7
5
6
4
2
3
1
.
-
0
9
ENTER
CANCEL
ESCAPE
Chapter 6 Normal Mode
41
6
8
8
8
8
8 Calculation Setup
The following calculation modes can be set for the area (A1 to A4) specified on the
AREA SETUP screen. Addition and subtraction using data of several areas can be
set.
■ Calculation for each area
OFF
: The measured value is not used for calculation.
+A#
: The measured value is output without changes.
+A#/2 : The measured value is multiplied by “1/2”.
+A#/3 : The measured value is multiplied by “1/3”.
:
–A#/4 : The measured value is multiplied by “-1/4”.
*
A# indicates either of A1 to A4.
Calculation using data of several areas
Calculation setup
When the calculation modes are set as shown above, the calculation result of
“+A1+(+A2)+(-A3)” is output.
[Example 1]
When two scanning heads are installed along two axes, the average value of the
wire’s outer diameter is output.
Setting Status
1/2 of the outer diameters
measured with HEAD 1 and
HEAD 2 are added.
[AREA SETUP]
OPTIONS
OUTPUT
OUT1
• • •
OUT4
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
+A2
+A3
OFF
AREA1
AREA2
AREA3
AREA4
500
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
+A1
+A2
–A3
OFF
AREA1
AREA2
AREA3
AREA4
LASER ON
AREA SETUP
NOR
MAL
P. 1
EDGEI
EDGEI
HEAD1
( 2, 3)
ESC
HELP
SET
HEAD No.
EDGE No.
A1
SEGMENT
HEAD2
( 2, 3)
SET
HEAD No.
EDGE No.
A2
SEGMENT
DIA
HEAD3
( 2, 3)
SET
HEAD No.
EDGE No.
A3
SEGMENT
DIA
HEAD4
( 2, 3)
SET
HEAD No.
EDGE No.
A4
SEGMENT
+A1/2
+A2/2
OFF
OFF
AREA1
AREA2
AREA3
AREA4
Chapter 6 Normal Mode
42
6
[Example 2]
Two scanning heads are used to measure a sheet width.
Setting Status
The measured values of HEAD
1 and HEAD 2 are both multi-
plied by “-1”, and the resulting
values are added.
■Setting Procedure
1. Select the OUTPUT MODE screen.
Press the [OPTIONS] button. The screen shown below is displayed.
2. Select the output number to be set.
Press the [OUTPUT] button.
Press the button corresponding to the output number for which calculation setup
is to be performed.
[AREA SETUP]
[OUTPUT] button
LASER ON
AREA SETUP
NOR
MAL
P. 1
EDGEI
EDGEI
HEAD1
( 2, 3)
ESC
HELP
SET
HEAD No.
EDGE No.
A1
SEGMENT
HEAD2
( 2, 3)
SET
HEAD No.
EDGE No.
A2
SEGMENT
DIA
HEAD3
( 2, 3)
SET
HEAD No.
EDGE No.
A3
SEGMENT
DIA
HEAD4
( 2, 3)
SET
HEAD No.
EDGE No.
A4
SEGMENT
–A1
–A2
OFF
OFF
AREA1
AREA2
AREA3
AREA4
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
Chapter 6 Normal Mode
43
6
OFF
–A1/4
+A1
+A1/2
+A1/3
+A1/4
–A1
–A1/2
–A1/3
3. Set the calculation modes.
Every time you press the [CALCULATE] button, the setting changes as shown
below. (For AREA 1)
OFF:
Calculation is set to OFF.
+A1:
The measured value is output without changes.
+A1/2: The measured value is multiplied by “1/2”.
+A1/3: The measured value is multiplied by “1/3”.
+A1/4: The measured value is multiplied by “1/4”.
–A1:
The measured value is multiplied by “–1”.
–A1/2: The measured value is multiplied by –1/2”.
–A1/3: The measured value is multiplied by “–1/3”.
–A1/4: The measured value is multiplied by “–1/4”.
Note:
OFF
+A2
+A2/2
+A2/3
OFF
+A3
+A3/2
+A3/3
OFF
+A4
+A4/2
+A4/3
For AREA 2
For AREA 3
For AREA 4
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
[CALCULATE] button
Chapter 6 Normal Mode
44
6
9
9
9
9
9 Average
The number of averaging measurements can be set based on the application as
follows.
•
Increase the number of averaging measurements:
To average fluctuations in measured values to obtain stable data
•
Reduce the number of averaging measurements:
To increase high speed differentiation speed
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the OUTPUT MODE screen.
Press the [OUTPUT] button.
3. Set the number of averaging measurements.
Press the button corresponding to the output number for which the number of
averaging measurements is to be set.
Press the [AVERAGE] button and set a number of averaging measurements.
OPTIONS
OUTPUT
OUT1
• • •
OUT4
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
Chapter 6 Normal Mode
45
6
[Relationship between number of averaging measurements and averaging time]
No. of averaging
Averaging time
measurements
1
0.833 ms
2
1.67 ms
4
3.33 ms
8
6.67 ms
12
10 ms
24
20 ms
48
40
No. of averaging
Averaging time
measurements
96
80 ms
192
160 ms
384
320 ms
768
640 ms
1538
1.28 s
3072
2.56 s
6144
5.12 s
Note: The averaging time is not the same as output response time.
➮ For output response time, see p. 121.
Chapter 6 Normal Mode
46
6
0
0
0
0
0 Measuring mode
The LS-5000 series provides the following nine measuring modes.
Mode
Description
Normal
The measured value and comparator output are displayed/
output at any time.
Peak hold
The maximum value during a specified period is measured.
Bottom hold
The minimum value during a specified period is measured.
Difference hold
The difference between the maximum and minimum values
during a specified period is measured.
Auto peak hold
The maximum measured value is retained.
Auto bottom hold
The minimum measured value is retained.
Auto difference hold
The difference between the maximum and minimum values is
retained.
Sample hold
The instantaneous value at a specified time is measured.
Self-timing
Automatic measurement without using external synchronous
input. Only with DIA or SEG (m, n).
[Applications of each mode]
• Normal mode
Used for normal continu-
ous measurement.
• Peak hold
• Auto peak hold
Used to measure the maxi-
mum value of the target.
Measures
this diameter.
• Bottom hold
• Auto bottom hold
Used to measure the
minimum value of the
target.
Measures
this diameter.
• Difference hold
• Auto difference hold
Measures
this width.
OPTIONS
OUTPUT
OUT1
• • •
OUT4
Chapter 6 Normal Mode
47
6
■ Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the OUTPUT MODE screen.
Press the [OUTPUT] button.
Press the button corresponding to the output number for which the measuring
mode is to be set.
3. Set the measuring mode.
Press the [MEASURING MODE] button to set the measuring mode.
Every time the [MEASURING MODE] button is pressed, the indication changes
in the above order.
[When the self-timing mode is selected] [Only with DIA or SEG (m, n)]
4. Set the self-timing interval.
Press the [SELF-TIMING INTERVAL] button to set the self-timing interval.
Every time the [SELF-TIMING INTERVAL] button is pressed, the setting
changes in the following order.
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
NORMAL
PEAK
BOTTOM
DIFFERENCE
AUTO-DIFFERENCE
AUTO-BOTTOM
AUTO-PEAK
SELF-TIMING
SAMPLE
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
500
1000
10
50
100
200
Chapter 6 Normal Mode
48
6
Note 1: The self-timing setting is effective only when self-timing mode is selected.
Note 2: The self-timing interval should be set longer than the averaging time.
Note 3: Self-timing mode is enabled only when DIA or SEG(m,n) is selected.
(When T.EDGE or B.EDGE is selected, self-timing mode is disabled.)
●Normal mode
The measurement value/comparator output can be displayed/output at any time.
Timing Diagram
●Peak hold mode
The maximum value during a specified period can be measured.
The sampling period is the duration between the falling edge and the next rising
edge of the synchronous input.
Timing Diagram
Note: When the reset input terminal and the GND terminal are short-circuited, the
retained value is reset and measurement starts again.
* When the synchronous input is ON, the displayed value/comparator output is retained.
Preset upper limit
Displayed value
Preset lower limit
HI OUT
ON
OFF
ON
OFF
ON
OFF
ON
OFF
GO OUT
LO OUT
Synchronous
input
(t)
Internal
measurement
Measured
value
ON
OFF
Synchronous
input
Power-ON or
RESET input
(t)
After the power-ON or RESET input is activated,
“-----” is displayed until the synchronous input is turned ON.
Peak hold value
Sampling
period
Sampling
period
Sampling
period
Chapter 6 Normal Mode
49
6
●Bottom hold mode
The minimum value during a specified period can be measured.
The sampling period is the duration between the falling edge and the next rising
edge of the synchronous input.
Timing Diagram
●Difference mode
The difference between the maximum and minimum values during a specified
period can be measured.
Timing Diagram
Note: When the reset input terminal and the GND terminal are short-circuited, the
retained value is reset to the present value and measurement starts again.
ON
OFF
Synchronous
input
Power-ON or
RESET input
(t)
After the power-ON or RESET input is activated,
“-----” is displayed until the synchronous input is turned ON.
Bottom hold
displayed value
Sampling
period
Sampling
period
Sampling
period
Internal
measurement
Measured
value
ON
OFF
Synchronous
input
Measured
value
Power-ON or
RESET input
(t)
After the power-ON or RESET input is activated,
“-----” is displayed until the synchronous input is
turned ON.
Difference hold
displayed value
Sampling
period
Sampling
period
Internal
measurement
b
b'
P
P'
(P-b)
(P'-b')
Chapter 6 Normal Mode
50
6
●Auto peak hold mode
The maximum value after measurement starts can be measured.
Timing Diagram
●Auto bottom hold mode
The minimum value after measurement starts can be measured.
Timing Diagram
Note: When the reset input terminal and the GND terminal are short-circuited, the
retained value is reset to the present value and measurement starts again.
ON
OFF
Synchronous
input
ON
OFF
Reset input
(t)
Auto bottom hold value
Measured
value
Internal
measurement
ON
OFF
Synchronous
input
ON
OFF
Reset input
(t)
Auto peak hold value
Internal
measurement
Measured
value
Chapter 6 Normal Mode
51
6
●Auto difference hold mode
The difference between the maximum and minimum values after measurement
starts can be measured.
Timing Diagram
●Sample hold mode
The instantaneous value at a specified time can be measured.
Timing Diagram
Note: When the reset input terminal and the GND terminal are short-circuited, the
retained value is reset to the present value and measurement starts again.
ON
OFF
Synchronous
input
ON
OFF
Power-ON or
RESET input
(t)
Auto difference
hold value
Measured
value
Internal
measurement
ON
OFF
Synchronous
input
Power-ON or
RESET input
(t)
Sample hold
value
Measured
value
Internal
measurement
After the power-ON or RESET input is activated,
“-----” is displayed until the synchronous input is turned ON.
Chapter 6 Normal Mode
52
6
●Self-timing mode
Measurement is automatically performed according to the internal synchronous
signal.
Timing Diagram
Note 1: When the self-timing hold mode is used, the external synchronous input is
ignored.
Note 2: When the reset input terminal and the GND terminal are short-circuited,
the retained value is reset and measurement starts again.
■Target recognition method in self-timing mode
The LS-5000 series’ self-timing mode takes a specified duration to start sample-
holding after the LS-5001 has recognized that a target has been placed in the
measuring area. (The target recognition method varies depending on the
SEGMENT.)
The LS-5001 can measure a target regardless of the direction it enters the
measuring area from.
Internal measurement
Self-timing value
No target
No target
Target enters the
measuring area
Target goes out
of the measur-
ing area
Preset
self-timing
interval
Preset
self-timing
interval
Internal
synchronous
signal
Measured
value
ON
(t)
OFF
After the power-ON or RESET input is activated,
“-----” is displayed until the internal synchronous signal is turned ON.
Target enters the
measuring area
Target goes out
of the measur-
ing area
Chapter 6 Normal Mode
53
6
1
Edge No.
2
1
Edge No.
2
3
4
Target recognition method by measuring mode
•
DIA mode: A target is recognized when the number of edges in the measuring
area is two or more.
The target has not yet been recog-
nized.
The LS-5001 recognizes that a
target has been placed in the
measuring area when the number of
edges in the measuring area is two
or more.
•
SEG (m, n) mode: A target is recognized when a specified number of edges is
generated in the measuring area.
When SEG(2,3) is set:
The target has not yet been recog-
nized because the specified number
of edges (Edge No.) is not present in
the measuring area.
The target has been recognized
when the specified number of edges
is generated in the measuring area.
Chapter 6 Normal Mode
54
6
A
A
A
A
A Digit Suppression Function
The digits after the decimal point can be suppressed as required.
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Select the OUTPUT MODE screen. Press the [OUTPUT] button.
3. Change the number of digits.
Press the button corresponding to the output number for which the number of
digits is to be changed.
Every time you press the [DIGIT SUPPRESS] button, the display changes in
the following order. The value indicates the number of digit to be suppressed.
Note: The relationship between each switch setting and the number of displayed
digits is as follows:
Example
(Displays 5 digits after the decimal point: 10.00000 mm/1.000000 inch)
(Displays 4 digits after the decimal point: 10.0000 mm/1.00000 inch)
(Displays 3 digits after the decimal point: 10.000 mm/1.0000 inch)
(Displays 2 digits after the decimal point: 10.00 mm/1.000 inch)
(Displays 1 digit after the decimal point: 10.0 mm/1.00 inch)
OPTIONS
OUTPUT
OUT1
• • •
OUT4
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
NONE
1
2
3
4
NONE
1
2
3
4
Chapter 6 Normal Mode
55
6
B
B
B
B
B Offset Function
The desired value can be added to or subtracted from the displayed value.
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Select the OUTPUT MODE screen. Press the [OUTPUT] button.
3. Press the button corresponding to the output number for which the offset
function is to be set.
4. Press the [NEXT] button.
5. Set the offset function. Press the [OFFSET] button.
OPTIONS
OUTPUT
OUT1
• • •
OUT4
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
OUTPUT MODE
OUT1
LASER ON
P. 1
NOR
MAL
OFFSET
+10 V=
-10 V=
40.0000
0.0000
0.0000
ANALOG OUT
ESC
PREV
Chapter 6 Normal Mode
56
6
6. Enter an offset value using the numeric keys, and press [ENTER].
Note: The maximum and minimum offset values are as follows:
Max.: 999.9999 (9.99999)
Min.: -99.9999 (-0.99999)
Values in ( ) are in inches.
OUTPUT MODE
OUT1
LASER ON
P. 1
NOR
MAL
8
7
5
6
4
2
3
.
-
1
0
9
ENTER
CANCEL
ESCAPE
OFFSET
+10 V=
-10 V=
40.0000
0.0000
0.0000
ANALOG OUT
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry.
The value returns to the previous value.
Chapter 6 Normal Mode
57
6
C
C
C
C
C Analog Output Function
An analog voltage proportional to the displayed value can be output using an
optional I/O board in the range of ±10 V.
The analog output scaling range is between -99.9999 and 999.9999 in “mm” (-
0.99999 and -99.9999 in “inch”), and the ripple is 5 mV.
●Scaling
The analog output is scaled to set the changing rate (inclination) of the analog
output relative to the displayed value. Enter a value to be displayed, relative to +10
V and -10 V respectively.
When the analog output is set to “+10 V = 30.000” and “-10 V = 10.000”, the
relation between analog output and displayed value is as follows:
Note: Resolution
The resolution of the LS-5000 series’ analog output is 5 mV. The resolution in
displayed value varies depending on the scaling.
Example 1
When the analog output is set to “+10 V = 10.000” and “-10 V = -10.000”:
20 (V) : 0.005 (V) = 20 (mm) : x (mm) x = 0.005 mm
Example 2
When the analog output is set to “+10 V = 40.000” and “-10 V = 0.0000”:
20 (V) : 0.005 (V) = 40 (mm) : x (mm) x = 0.010 mm
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Select the OUTPUT MODE screen. Press the [OUTPUT] button.
+10 V
Analog
output
Displayed
value
-10 V
10.000
30.000
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
Chapter 6 Normal Mode
58
6
3. Set the analog output function.
Press the button corresponding to the output for which the analog output func-
tion is to be set.
4. Press the [NEXT] button.
5. Press the [ANALOG OUTPUT] button.
Using the numeric keys, enter an analog output value in the location indicated
by the dotted line.
Note 1: When “-----” is displayed, the analog output is retained at +10 V.
Note 2: When the displayed value exceeds the preset scaling range, the analog
output is retained at +10 V. (When the displayed value falls below the scaling
range, the analog output is retained at -10 V.)
[Example]
When the analog output is set to “+10 V = 30.000” and “-10 V =
10.000”:
When the displayed value is 30 or more, the analog output is
retained at +10 V.
When the displayed value is 10 or less, the analog output is
retained at -10 V.
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
OUTPUT MODE
OUT1
LASER ON
P. 1
+A1
OFF
OFF
OFF
AREA1
AREA2
AREA3
AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESC
HELP
NEXT
NOR
MAL
OUTPUT MODE
OUT1
LASER ON
P. 1
NOR
MAL
OFFSET
+10 V=
-10 V=
40.0000
0.0000
0.0000
ANALOG OUT
ESC
PREV
OUTPUT MODE
OUT1
LASER ON
P. 1
NOR
MAL
8
7
5
6
4
2
3
.
-
1
0
9
ENTER
CANCEL
ESCAPE
OFFSET
+10 V=
-10 V=
40.0000
0.0000
0.0000
ANALOG OUT
+10 V
-10 V
10.000
30.000
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry.
The value returns to the previous value.
Chapter 6 Normal Mode
59
6
D
D
D
D
D I/O Slot Setup
The expansion I/O board can be set. ➮ See p. 100.
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Select the OUTPUT MODE screen. Press the [OUTPUT] button.
3. Press the [I/O SLOT SETUP] button.
4. Set the output number.
Every time you press the button, the display changes in the following order.
Note 1: When there is no I/O board mounted
in the expansion slot, the display is as
shown on the right.
Note 2: When an I/O board is mounted in
the expansion slot, the same output number
cannot be set for different channels.
OPTIONS
OUTPUT MODE
I/O SLOT
SET UP
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
OUT1
OUT2
OUT3
OUT4
NONE
LASER ON
I/O SLOT SETUP
NOR
MAL
P. 1
I/O
OUT1
HEAD1
NONE
HEAD2
NONE
HEAD1
NONE
HEAD2
SLOT1
CH1
I/O
CH2
NONE
SLOT2
CH1
NONE
CH2
ESC
The I/O board mounted in the expansion slot is shown.
LASER ON
I/O SLOT SETUP
NOR
MAL
P. 1
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
SLOT1
CH1
CH2
SLOT2
CH1
CH2
ESC
Chapter 6 Normal Mode
60
6
E
E
E
E
E Inspection
The scanning head can be checked for conditions such as dust on the front
surface, laser condition, and optical axis alignment.
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Select the INSPECT screen. Press the [INSPECT] button.
3. Check the condition of the scanning head.
Press the button corresponding to the scanning head to be inspected.
When the condition of the scanning head is normal, the display is as shown
below.
Note 1: During the scanning head inspection, measurement is interrupted. (The
comparator output and analog output are the same as when “-----” is displayed.)
Comparator output: All outputs are OFF.
Analog output: Retained at +10 V.
Note 2: When any problem occurs with the laser diode, the message “LASER” is
displayed on the screen.
OPTIONS
OUTPUT
OUT1
• • •
OUT4
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
INSPECT
NOR
MAL
P. 1
HEAD1
HEAD2
HEAD3
HEAD4
ESC
Select Head to inspect.
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: OK
OPTICAL AXIS
ESC
NOR
MAL
Chapter 6 Normal Mode
61
6
●Optical axis misalignment indications
Optical axis misalignment is indicated when the receiver is tilted relative to the
optical axis.
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: OK
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: OK
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
BEAM INTENSITY
HEAD R
: NG
: NG
OPTICAL AXIS
ESC
NOR
MAL
INSPECT
HEAD1
LASER ON
P. 1
ESC
NOR
MAL
Laser beam is tgurned off.
Optical axis cannot be checked.
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
Receiver
Transmitter
The receiver is
tilted upward.
The receiver is
tilted to the
upper left
(viewed from
the transmit-
ter).
The transmitter
is tilted to the
right (viewed
from the
transmitter).
The optical
axis is aligned.
The receiver is
tilted to the left
(viewed from
the transmitter).
The receiver is
tilted to the
lower right
(viewed from
the
transmitter).
The receiver is
tilted
downward.
The receiver is
tilted to the
lower left
(viewed from
the transmit-
ter).
The receiver is
tilted to the
upper right
(viewed from
the transmitter).
No optical axis enters the receiver.
Laser beam is not emitted.
Normal Alignment
Chapter 6 Normal Mode
62
6
F
F
F
F
F One-scan Mode
Data on only one of the 12 surfaces of the polygon mirror becomes effective.
(This mode negates slight changes in the optical axis caused by the polygon mirror
surface runout.) This is effective for measuring a narrow gap as shown below.
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the UTILITY screen.
Press the [UTILITY] button.
3. Set the one-scan mode.
Press the [ONE-SCAN MODE] button to turn it ON.
Every time you press this button, the display toggles between ON and OFF.
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
UTILITY
NOR
MAL
P. 1
AREA CHECK
INITIALIZE
ON
PANEL
mm
ONE-SCAN MODE
PROGRAM SELECT
DISPLAY UNIT
ESC
Optical axis
OPTIONS
UTILITY
Chapter 6 Normal Mode
63
6
Note: The laser beam spot diameter is 0.2 mm at a distance of 80 mm from the
transmitter. For gap measurement, however, a gap width of 0.3 mm or more is
required.
When the one-scan mode is used, the averaging time1. is longer than in normal
measuring mode.
No. of averaging measurements and averaging time
when one-scan mode is ON/OFF
1. The averaging time is not the same as mean output response time. For the
output response time, see p. 121.
0.3 mm or more gap width is required.
OFF
ON
Averaging time
1
1
10 ms
2
1
10 ms
4
1
10 ms
8
1
10 ms
12
1
10 ms
24
2
20 ms
48
4
40 ms
96
8
80 ms
192
16
160 ms
384
32
320 ms
768
64
640 ms
1536
128
1280 ms
3072
256
2460 ms
6144
512
5120 ms
Chapter 6 Normal Mode
64
6
G
G
G
G
G Program Selection Method Setup
The program selection method can be set to the front panel or the rear terminals.
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Select the UTILITY screen. Press the [UTILITY] button.
3. Set the program selection method.
Press the [PROGRAM SELECT] button to select [PANEL] or [EXT].
Every time you press the button, the display toggles between [PANEL] and
[EXT].
Note 1: When the program selection method is set to [PANEL], program selection
can be performed using the front panel and the RS-232C input.
Note 2: When the program selection method is set to [EXT], program selection can
be performed using the terminal input only.
Note 3: When the panel lock function is used, program selection is performed as
shown below.
➮ For information on the panel lock function, see p. 112.
OPTIONS
UTILITY
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
UTILITY
NOR
MAL
P. 1
AREA CHECK
INITIALIZE
ON
PANEL
mm
ONE-SCAN MODE
PROGRAM SELECT
DISPLAY UNIT
ESC
Program selection
Panel
Terminal
Front panel
Enabled
Disabled
Terminal input
Disabled
Enabled
RS-232C input
Enabled
Disabled
Program selection
Panel
Terminal
Front panel
Disabled
Disabled
Terminal input
Disabled
Enabled
RS-232C input
Enabled
Disabled
Chapter 6 Normal Mode
65
6
H
H
H
H
H Display Unit
The measured value can be displayed in millimeters or inches.
Note: When the display units setting is changed, the preset values (tolerance
limits, etc.) of the selected program number are reset to the initial settings.
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the UTILITY screen.
Press the [UTILITY] button.
3. Set the display unit.
Press the [DISPLAY UNIT] button to select [mm] or [inch].
Every time you press the button, the display toggles between [mm] and [inch].
OPTIONS
UTILITY
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
UTILITY
NOR
MAL
P. 1
AREA CHECK
INITIALIZE
ON
PANEL
mm
ONE-SCAN MODE
PROGRAM SELECT
DISPLAY UNIT
ESC
Chapter 6 Normal Mode
66
6
I
I
I
I
I Area Check Function
When the number of edges changes during measurement, the area check function
displays the “----” error message. It also cancels the measured value by detecting
the difference from the preset total number of edges.
■Effective Application
When dust or oil adheres to the scanning head or no target is placed in the
measuring area, the area check function prevents an abnormal measured value
from being displayed or output.
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the UTILITY screen.
Press the [UTILITY] button.
3. Press the [AREA CHECK] button.
4. Set the number of edges.
Press the [SET] button.
Enter a value using the numeric keys.
Press the [OFF] button to turn it ON.
Every time you press the button, the display toggles between [ON] and [OFF].
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
UTILITY
NOR
MAL
P. 1
AREA CHECK
INITIALIZE
ON
PANEL
mm
ONE-SCAN MODE
PROGRAM SELECT
DISPLAY UNIT
ESC
LASER ON
AREA CHECK
NOR
MAL
P. 1
OFF
ESC
SET
HEAD No.
HEAD1
A1
NO. OF
EDGES
( 4 )
DIA
SEGMENT
OFF
SET
HEAD No.
HEAD1
A2
NO. OF
EDGES
( 4 )
DIA
SEGMENT
SEGMENT
SEGMENT
OFF
SET
HEAD No.
HEAD1
A3
NO. OF
EDGES
( 4 )
DIA
OFF
SET
HEAD No.
HEAD1
A4
NO. OF
EDGES
( 4 )
DIA
Chapter 6 Normal Mode
67
6
J
J
J
J
J Initialize
This function resets all settings to the initial values. ➮ See p. 116 and 117.
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the UTILITY screen.
Press the [UTILITY] button.
3. Perform initialization.
Press the [INITIALIZE] button.
4. Press the [YES] button.
5. Press the [OK] button.
OPTIONS
UTILITY
AREA CHECK
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
UTILITY
NOR
MAL
P. 1
AREA CHECK
INITIALIZE
ON
PANEL
mm
ONE-SCAN MODE
PROGRAM SELECT
DISPLAY UNIT
ESC
LASER ON
INITIALIZE
NOR
MAL
P. 1
Initialize the current settings?
YES
NO
LASER ON
INITIALIZE
NOR
MAL
P. 1
The current settings
will be initialized.
OK
CANCEL
Chapter 6 Normal Mode
68
6
K
K
K
K
K Mode Change
The measuring mode can be changed from Normal mode to Pitch mode.
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Change the measuring mode.
Press the [CHANGE MODE Normal -> Pitch] button.
3. Press the [YES] button.
Press the [OK] button.
OPTIONS
MODE CHANGE
Normal
Pitch
LASER ON
OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
CALIB
OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON
MODE CHANGE
NOR
MAL
P. 1
Change the Pitch Mode?
YES
NO
LASER ON
MODE CHANGE
NOR
MAL
P. 1
Mode changed to Pitch.
OK
CANCEL
This section describes functions and settings procedures for Pitch mode.
7.1
Pitch Mode Screens ............................................................ 70
7.2
Initial Screen .......................................................................71
7.3
Setting Measurement ......................................................... 72
7.4
Setting Functions ...............................................................73
Chapter 7 Pitch Mode
70
7
7.1
Pitch Mode Screens
LASER ON
OPTIONS
P. 1
PITCH
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
MODE
CHANGE
Pitch
-> Normal
MODE
CHANGE
Pitch
-> Normal
LASER ON
DISPLAY DATA
P. 1
PITCH
HEAD1
OK
Max
0.5010
Min
ESC
ON
HEAD1
OFF
HEAD2
OFF
HEAD3
OFF
HEAD4
Set Output to display data.
LASER ON
DISPLAY SETUP
PITCH
P. 1
0.4990
SCREEN
SCREEN
HEAD1
HEAD4
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
OK
Max
Min
0.5010
0.4990
HEAD2
OK
Max
Min
0.6010
0.5990
HEAD3
OK
Max
Min
0.7020
0.6980
HEAD4
OK
Max
Min
0.8020
0.7980
SCREEN
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
OK
Max
Min
0.5010
0.4990
HEAD2
OK
Max
Min
0.6010
0.5990
HEAD3
OK
Max
Min
0.7020
0.6980
SCREEN
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
LASER ON
LIMIT SETUP
P. 1
PITCH
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
Select Head to set the limits.
LIMIT SETUP
HEAD1
LASER ON
P. 1
PITCH
8
7
5
6
4
2
3
1
0
9
ENTER
CANCEL
ESCAPE
+0.0100
1.0000
UPPER LIMIT:
REFERENCE:
LOWER LIMIT:
-0.0100
HEAD1
HEAD4
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
OK
Max
0.5010
Min
0.4990
HEAD2
OK
Max
0.6010
Min
0.5990
SCREEN
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
LASER ON
SELECT PROGRAM No.
P. 1
PITCH
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
Selected program No.
1
5
8
7
6
4
2
3
1
13
16
15
14
12
10
11
9
OPTIONS
LASER ON
MODE CHANGE
P. 1
PITCH
Change to Normal mode?
YES
NO
➮ See p.73.
➮ See p.73.
➮ See p.73.
➮ See p.75.
➮ See p.75.
➮ See p.73.
➮ See p.76.
➮ See p.77 - 84.
➮ See p.73.
➮ See p.77.
➮ See p.85.
DISPLAY DATA screen
DISPLAY SETUP screen
DISPLAY DATA screen
LIMIT SETUP screen
LIMIT SETUP screen
DISPLAY DATA screen
SELECT PROGRAM NO. screen
MEASUREMENT SETUP screen
DISPLAY DATA screen
OPTIONS screen
MODE CHANGE screen
Chapter 7 Pitch Mode
71
7
7.2
Initial Screen
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
OK
Max
Min
0.5010
0.4990
HEAD2
OK
Max
Min
0.6010
0.5990
HEAD3
OK
Max
Min
0.7020
0.6980
HEAD4
OK
Max
Min
0.8020
0.7980
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
Laser ON/OFF
status
Screen title
Measuring mode
Program
No.
Screen
selection
switch
To the
OPTIONS
screen
To the SELECT
PROGRAM NO.
screen
To the LIMIT
SETUP
screen
To the
DISPLAY
DATA screen
Only the maximum and
minimum values of
scanning head 1 are
displayed.
Chapter 7 Pitch Mode
72
7
7.3
Setting Measurement
When Pitch mode is selected, only one measurement can be performed with one
scanning head, unlike in Normal mode. Therefore, Pitch mode setup must be
performed for each scanning head.
■Setting Procedure
OPTIONS
OUT1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
HEAD1
HEAD4
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
OPTIONS
Indicates the scanning head number
for which Pitch mode is being set.
Set the number
of averaging
measurements.
Set the digit
suppression
function.
Set the
measuring
mode.
Set the masking function.
Set the number of pitches.
Chapter 7 Pitch Mode
73
7
7.4
Setting Functions
Switch
Function
Description
Reference
page
DATA DISPLAY
Screen Selection
Measurement results are
72, 73
displayed.
LIMIT SETUP
Limit Setup
Upper and lower limits can be set
75
relative to the reference value for
each output.
PROGRAM
Program
Measurement conditions can be
76
SELECT
Selection
stored and retrieved as programs.
OPTIONS
No. of Pitches
Set the number of pitches
77
according to the target.
Average
Measurement results can be
79
averaged.
Digit suppression
The number of digits after the
80
decimal point can be set.
M. Mode
Three measuring modes are
81-83
provided.
Masking
Set the pitch number for the
84
measurement to be canceled.
Mode Change
Normal mode or Pitch mode
85
can be selected.
For each scanning head
1
1
1
1
1 Screen Selection Function
Using the screen selection function, set the measured value display screen (OUT1
to OUT4).
[Example 1: Four measurement results are displayed.]
[Example 2: One measurement result is displayed.]
DISPLAY
DATA
SCREEN
LASER ON
DISPLAY SETUP
P. 1
ON
HEAD1
ON
HEAD2
ON
HEAD3
ON
HEAD4
ESC
Set Output to display data.
LASER ON
DISPLAY DATA
PITCH
PITCH
P. 1
HEAD1
OK
Max
Min
0.5010
0.4990
HEAD2
OK
Max
Min
0.6010
0.5990
HEAD3
OK
Max
Min
0.7020
0.6980
HEAD4
OK
Max
Min
0.8020
0.7980
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
LASER ON
DISPLAY SETUP
P. 1
ON
HEAD1
OFF
HEAD2
OFF
HEAD3
OFF
HEAD4
ESC
Set Output to display data.
LASER ON
DISPLAY DATA
PITCH
PITCH
P. 1
HEAD1
OK
Max
0.5010
Min
0.4990
SCREEN
DISPLAY
DATA
LIMIT
SET UP
PROGRAM
OPTIONS
Chapter 7 Pitch Mode
74
7
■Setting Procedure
1. Select the DISPLAY DATA screen.
Press the [DISPLAY DATA] button.
Press the [SCREEN] button.
2. Select the data display screen.
Press the button corresponding to the output to be displayed to turn it ON.
Press the [ESC] button.
3. The screen has been changed.
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
OK
Max
0.5010
Min
0.4990
HEAD2
OK
Max
0.6010
Min
0.5990
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
LASER ON
DISPLAY SETUP
P. 1
ON
HEAD1
ON
HEAD2
ON
HEAD3
ON
HEAD4
ESC
Set Output to display data.
PITCH
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
OK
Max
Min
0.5010
0.4990
HEAD2
OK
Max
Min
0.6010
0.5990
HEAD3
OK
Max
Min
0.7020
0.6980
HEAD4
OK
Max
Min
0.8020
0.7980
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
Chapter 7 Pitch Mode
75
7
2
2
2
2
2 Limit Setup
The reference value, upper limit, and lower limit can be set separately for each of
the four scanning heads.
■Setting Procedure
1. Select the LIMIT SETUP screen.
Press the [LIMIT SETUP] button.
2. Set tolerance limits.
Press the button corresponding to the output for which tolerance limits are to be
set.
Set tolerance limits using the numeric keys, and press [ENTER].
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The value returns to the previous value.
Note: When the measured value exceeds the tolerance range, the value is dis-
played in reverse. The differentiation result relative to the tolerance limits is output
from the display unit and the control I/O board (optional).
When the measured value exceeds the upper limit or falls below the lower limit, the
HI1 output is turned on.
In PITCH mode, the Upper-Lower Limit indicates the difference from the Reference
value. If a measured value of more than 1.1000 mm is to be checked and the
Reference value is set to 1.000 mm, the Upper Limit should be +0.1000. If 0.9000
mm is to be checked, the Lower Limit should be -0.1000 mm.
HEAD1
• • •
HEAD4
LIMIT
SETUP
LASER ON
LIMIT SETUP
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
Select Head to set the limits.
LIMIT SETUP
HEAD1
LASER ON
P. 1
PITCH
8
7
5
6
4
2
3
1
0
9
ENTER
CANCEL
ESCAPE
+0.0100
1.0000
UPPER LIMIT:
REFERENCE:
LOWER LIMIT:
-0.0100
Chapter 7 Pitch Mode
76
7
3
3
3
3
3 Program Selection Function
The LS-5000 series can store all the measurement conditions as a program. Up to
16 programs can be stored and loaded easily.
■Setting Procedure
1. Select the SELECT PROGRAM NO. Screen.
Press the [PROGRAM] button.
2. Select a program number.
Press the button corresponding to the desired program number.
Note: When the program selection method is set to the rear terminals, the program
number cannot be changed using the front panel. ➮ See p. 64.
LASER ON
SELECT PROGRAM No.
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
Selected program No.
1
5
8
7
6
4
2
3
1
13
16
15
14
12
10
11
9
• • •
PROGRAM
1
16
Chapter 7 Pitch Mode
77
7
4
4
4
4
4 Setting Number of Pitches
The number of pitches can be set up to 100, depending on the target.
Example: IC lead pitch measurement
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Set the number of pitches.
Press the button corresponding to the output for which the number of pitches is
to be set.
3. Press the [NO. OF PITCHES] button.
4. Enter a value using the numeric keys, and press [ENTER].
Press [ESCAPE] to complete the entry.
Press [CANCEL] to cancel the entry. The value returns to the previous value.
1
2
3
The number
of pitches is "3".
HEAD1
NO. OF
PITCHES
• • •
HEAD4
OPTIONS
LASER ON
OPTIONS
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
MODE
CHANGE
Pitch
-> Normal
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
8
7
5
6
4
2
3
1
0
9
ENTER
CANCEL
ESCAPE
NO. OF
PITCHES
MASKING
10
AVERAGE
8
MASK1:
PITCH No.
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
Chapter 7 Pitch Mode
78
7
Note 1: Up to 100 pitches can be set.
Note 2: When the number of pitches for a target is different from the preset number
of pitches, “-----” is displayed and "Err" appears. (When the error message is
displayed, the HI3 output of the control I/O board (optional) is turned ON.)
Missing pin
LASER ON
DISPLAY DATA
PITCH
P. 1
HEAD1
Err
Max
- - - - - - -
Min
- - - - - - -
SCREEN
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
Chapter 7 Pitch Mode
79
7
5
5
5
5
5 Average
The number of averaging measurements can be set, according to the application,
as follows:
•
Increase the number of averaging measurements to average fluctuations in
measured values to obtain stable data.
•
Reduce the number of averaging measurements to increase differentiation
speed.
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Set the number of averaging measurements.
Press the button corresponding to head number for which the number of
averaging measurements is to be set.
Press this button and set the number of averaging measurements.
Every time you press this button, the display changes in the following order.
[Relationship between No. of averaging measurements and averaging time]
Note: The averaging time is not the same as mean output response time. For
information on output response time, see p. 121.
HEAD1
• • •
HEAD4
OPTIONS
LASER ON
OPTIONS
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
MODE
CHANGE
Pitch
-> Normal
1
2
4
8
16
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
No. of averaging measurements
Averaging time
1
10 ms
2
20 ms
4
40 ms
8
80 ms
16
160 ms
Chapter 7 Pitch Mode
80
7
6
6
6
6
6 Digit Suppression Function
The number of digits after the decimal point can be suppressed as desired.
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Set the number of digits.
Press the button corresponding to the scanning heads for which the number of
digits is to be set.
Press this button to select the number of digits.
Every time you press this button, the display changes in the following order.
Note: The relationship between each switch setting and the displayed digits is as
follows:
Example
(Displays 5 digits after the decimal point:
10.00000 mm/1.000000 inch)
(Displays 4 digits after the decimal point:
10.0000 mm/1.00000 inch)
(Displays 3 digits after the decimal point:
10.000 mm/1.0000 inch)
(Displays 2 digits after the decimal point:
10.00 mm/1.000 inch)
(Displays 1 digit after the decimal point:
10.0 mm/1.00 inch)
LASER ON
OPTIONS
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
MODE
CHANGE
Pitch
-> Normal
NONE
1
2
3
4
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
HEAD1
• • •
HEAD4
OPTIONS
NONE
1
2
3
4
Chapter 7 Pitch Mode
81
7
7
7
7
7
7 Measuring Mode
The LS-5000 series provides the following three measuring modes.
LASER ON
OPTIONS
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
MODE
CHANGE
Pitch
-> Normal
NORMAL
SAMPLE
SELF-TIMING
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
100
200
500
1000
10
50
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
■ Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Set the measuring mode.
Press the button corresponding to the head for which the measuring mode is to
be set.
Press this button to select the measuring mode.
Every time you press this button, the display changes in the following order.
[When self-timing mode is selected]
3. Set the self-timing interval.
Every time you press this button, the display changes in the following order.
Note: The self-timing interval can be set only when self-timing mode is selected.
Mode
Description
Normal
The measured value and differentiation results are displayed/output
at any time.
Sample hold
The instantaneous value at a specified time is measured.
Self-timing
Automatic measurement without using external synchronous input.
Chapter 7 Pitch Mode
82
7
●Normal mode
The maximum and minimum values of the measured pitch and the differentiation
result can be displayed/output at any time.
Timing Diagram
•
The output when the synchronous input is turned ON is retained.
•
When the reset input is turned ON while the synchronous input is ON, “—” is
displayed and the Err output is turned ON.
●Sample hold mode
The instantaneous value at a specified time can be measured.
Timing Diagram
•
The value when the synchronous input is turned ON is retained.
•
When the reset input is turned ON, “—” is displayed and the Err output is turned
ON.
OK OUT
ON
Upper limit
Max. Value
Min. value
Lower limit
OFF
NG OUT
Synchronous input retains the
output status until it turns off.
ON
OFF
Err
Synchronous
input
ON
OFF
ON
OFF
OK
ON
OFF
NG
ON
OFF
Err
ON
OFF
ON
OFF
Upper limit
Max. Value
Min. value
Lower limit
Synchronous
input
Chapter 7 Pitch Mode
83
7
●Self-timing hold mode
Measurement can be automatically performed according to the internal synchro-
nous signal.
Timing Diagram
•
When the self-timing period has passed after a target is placed in the measuring
area, the measured value is retained.
•
The previous value is retained until the self-timing period has passed after the
next target is placed in the measuring area.
•
If the number of pitches of an actual target is different from the preset number of
pitches, self-timing mode is not activated even when the target is placed in the
measuring area.
OK ON
OFF
NG
ON
OFF
OFF
Err ON
No target
Target enters the
measuring area
No target
Preset
self-timing
interval
Preset
self-timing
interval
Upper limit
Max. value
Min. value
Lower limit
Target enters the
measuring area
Target goes out of
the measuring
area
Chapter 7 Pitch Mode
84
7
8
8
8
8
8 Masking
Up to three pitches can be excluded from measurement, based on the application,
as shown below.
If pitch (1) and pitch (13) are included in the measurement of connector lead
pitches as shown on the right, the maximum value becomes larger than the actual
value. The masking function is useful to cancel these unnecessary part in such a
case.
■Setting Procedure
1. Select the OPTIONS screen. Press the [OPTIONS] button.
2. Set the masking function.
Press the button corresponding to the output for which the masking function is
to be set.
3. Press the [MASKING] button.
Enter the pitch number to be canceled using the numeric keys, and press
[ENTER]. Press [ESCAPE] to complete the entry. Press [CANCEL] to cancel
the entry. The value returns to the previous value.
Note 1: Pitch number is counted from Pitch 1 in the scanning direction (from the top of the scanning
head to the bottom).
Note 2: When the total number of pitches changes (i.e. due to lead breakage), the control I/O board’s
HI3 output is turned ON which indicates an "Error with No. of Pitches”. (Except for the self-timing mode)
1
13
Pitches to be canceled
Scanning direction
Optical
axis
HEAD1
• • •
HEAD4
OPTIONS
LASER ON
OPTIONS
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
MODE
CHANGE
Pitch
-> Normal
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
MASK1:
PITCH No.
NO. OF
PITCHES
MASKING
10
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
AVERAGE
8
DIGIT
SUPPRESS
NONE
MEASUR-
ING MODE
NORMAL
SELF-TIMING
INTERVAL (ms)
100
ESC
OPTIONS
HEAD1
LASER ON
P. 1
PITCH
8
7
5
6
4
2
3
1
0
9
ENTER
CANCEL
ESCAPE
NO. OF
PITCHES
MASKING
10
AVERAGE
8
MASK1:
PITCH No.
0
MASK2:
PITCH No.
0
MASK3:
PITCH No.
0
In this example, set the No. of Pitches to 13.
In this example, set MASK1 to 1 and MASK2 to 13.
Chapter 7 Pitch Mode
85
7
9
9
9
9
9 Mode Change
The measuring mode can be changed from Pitch mode to Normal mode.
■Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Change the measuring mode from Pitch mode to Normal mode.
Press the [MODE CHANGE Pitch ➞ Normal] button.
3. Press the [YES] button.
4. Press the [OK] button.
LASER ON
OPTIONS
P. 1
PITCH
DISPLAY
DATA
LIMIT
SETUP
PROGRAM
OPTIONS
HEAD1
HEAD2
HEAD3
HEAD4
MODE
CHANGE
Pitch
-> Normal
LASER ON
MODE CHANGE
P. 1
PITCH
Change to Normal mode?
YES
NO
LASER ON
MODE CHANGE
P. 1
PITCH
Mode changed to Normal.
OK
CANCEL
OPTIONS
MODE CHANGE
Pitch
Normal
RS-232C Communication Protocol ................................... 88
8.2
Remote Control Function ................................................... 90
8.3
Command List .....................................................................97
Chapter 8 RS-232C I/O
88
8
8.1
RS-232C Communication Protocol
Using the RS-232C interface, the LS-5000 series can communicate with a personal
computer. Data transmission and setting changes can be remotely controlled.
■ Pin Assignment
1
2
3
4
5
6
Pin No.
Signal code
Description
Direction
of signal
1
—
No connection
—
2
—
No connection
—
3
SD (TXD)
Inputs data from
Input
external equipment
4
SG (GND)
Signal ground
—
5
RD (RXD)
Outputs measured
Output
value data
6
—
No connection
—
Example of Connections
Do not connect terminals (1), (2) and (6).
■ Communication Protocol
Conforming to EIA RS-232C
These settings can be changed by adjusting DIP switch 2.
When DIP switch 2 is set to ON and “STX + ETX” is selected, OUT1’s measured
value is output continuously.
3
5
4
2
3
4
6
7
8
5
SD
RD
SG
SD
RD
RS
CS
DR
ER
SG
LS
PC
RJ11 modular
connector
9 pin D-sub
connector
3
5
4
2
3
4
5
6
20
7
SD
RD
SG
SD
RD
RS
CS
DR
ER
SG
LS
PC
RJ11 modular
connector
25 pin D-sub
connector
DIP switch 2 setting
OFF
ON
Duplex
Full
Synchronization
Start-stop
Data format
ASCII
Data length
8
Stop bit length
1
Parity check
None
Even
Baud rate
9600
Delimiter
CR
STX + ETX
Applicable
Personal computer,
KV series (KV mode)
external equipment
KV-300 with KV-L2
(Non procedure mode)
■Setting Delimiter
1
2
3
4
ON
OFF
ON
OFF
STX +ETX
CR
DIP switch 2
DIP switch
Chapter 8 RS-232C I/O
89
8
■Examples of Connections
•
Connection with a personal computer
Delimiter: CR
•
Connection with the KV series
*
KV-300 series is not available in European area.
OP-26401 + OP-96368
(D-sub 9-pin connector + cable)
Personal computer
Straight cable
KV-10/16/24/40/80
KV-300 Series*
Cross cable OP-96607
Straight cable
OP-96368 (cable) + OP96369
(D-sub 25-pin connector)
AC
power supply
KV-U4
CPU
KV-300
Serial Interface
module KV-L2
Data format (Delimiter: STX + ETX)
The displayed value is output continuously.
Chapter 8 RS-232C I/O
90
8
8.2
Remote Control Function
You can control the LS-5000 series remotely by sending an ASCII command from
external equipment, such as a personal computer.
Character codes corresponding to the ASCII command can be used for remote
control.
Measured Value Output
RS-232C command list I
1. Upper line: Character code, Lower line: ASCII code (Hex)
Note 1: "#" is a character code between 0 and 4, or the ASCII code corresponding
to the character code.
0: Outputs data from all output numbers.
1 to 4: Outputs data from the specified output number (OUT1 to OUT4).
Note 2: When the ASCII (character) command given in command list I is received,
the measured value is sent either once or continuously.
■Operating Procedure
Example: Send the measured value from OUT No. 1 once.
Function
command received1.
Description
[M] [#] [CR]
Send a measured value once.
4DH#0DH
[N] [#] [CR]
Send a measured value continuously.
4EH#0DH
[O] [CR]
Stop continuous transmission of
4FH 0DH
meas
ured value.
Output of
measured value
LS-5000 series
During
measurement
During
measurement
Sends the measured
value once
Personal computer
Sends [M] [1] [CR]
End
Waiting to
receive data
Chapter 8 RS-232C I/O
91
8
Example: Send the measured value from OUT No. 2 continuously.
Note 1: When the LS-5000 series receives the “N” (continuous output) command in
either peak hold, bottom hold, difference hold, sample hold or self-timing mode, the
LS-5000 series sends the measured value once every time the synchronous input
is turned on (the measured value is confirmed).
Note 2: When the LS-5000 series receives the “N” (continuous output) command in
either normal, auto peak, auto bottom or auto difference hold mode, the LS-5000
series continuously sends the measured value.
■Data format
•
Received Command: [M] [1] [CR]
•
Transmitted data
In Normal mode
In Pitch mode
LS-5000 series
During
measurement
Sends the measured
value continuously
Stops the continuous
data transmission
Personal computer
Sends [N] [2] [CR]
Sends [O] [CR]
End
Receives data
continuously
During continuous
data transmission
First data Second data Third data 4th data
5th data
6th data
7th data
8th data
9th data
10th data
1
2
3
.
4
5
6
7
0
CR
(Displayed value: 123.45670)
–
SP
0
.
9
8
7
6
5
CR
(Displayed value:-0.98765)
First data Second data Third data 4th data
5th data
6th data
7th data
8th data
9th data
10th data
11th data
12th data 13th data
14th data
15th data
16th data
17th data
18th data
19th data
20th data
SP
SP
1
.
2
3
4
5
6
,
SP
SP
0
.
9
8
7
6
5
CR
(Displayed value: Max: 1.23450, Min.: 0.98765)
Chapter 8 RS-232C I/O
92
8
•
Received Command: [M] [0] [CR]
•
Transmitted data
In Normal mode
In Pitch mode
First data Second data Third data 4th data
5th data
6th data
7th data
8th data
9th data
10th data
11th data
12th data
13th data
14th data
15th data
16th data
17th data
18th data
19th data
20th data
1
2
3
.
4
5
6
7
0
,
–
SP
0
.
9
8
7
6
5
,
21th data
22th data
23th data
24th data
25th data
26th data
27th data
28th data
29th data
30th data
SP
SP
1
.
2
3
4
5
5
,
31th data
32th data
33th data
34th data
35th data
36th data
37th data
38th data
39th data
40th data
–
9
8
.
7
6
5
4
0
CR
(Displayed value: OUT1: 123.45670, OUT2: -0.98765,
OUT3: 1.23455, OUT4: -98.76540)
First data Second data Third data 4th data
5th data
6th data
7th data
8th data
9th data
10th data
11th data
12th data
13th data
14th data
15th data
16th data
17th data
18th data
19th data
20th data
SP
SP
1
.
2
3
4
0
0
,
SP
SP
1
.
2
3
0
0
0
,
21th data
22th data
23th data
24th data
25th data
26th data
27th data
28th data
29th data
30th data
SP
1
0
.
5
6
7
8
5
,
31th data
32th data
33th data
34th data
35th data
36th data
37th data
38th data
39th data
40th data
SP
1
0
.
5
5
7
8
5
,
41th data
42th data
43th data
44th data
45th data
46th data
47th data
48th data
49th data
50th data
SP
SP
2
.
3
4
5
6
0
,
51th data
52th data
53th data
54th data
55th data
56th data
57th data
58th data
59th data
60th data
SP
SP
2
.
4
5
6
7
0
,
61th data
62th data
63th data
64th data
65th data
66th data
67th data
68th data
69th data
70th data
SP
SP
0
.
3
4
5
6
0
,
71th data
72th data
73th data
74th data
75th data
76th data
77th data
78th data
79th data
80th data
SP
SP
0
.
2
3
4
5
5
CR
(Displayed value: OUT1 Max.: 1.23400, Min.: 1.23000, OUT2 Max.: 10.56785,
Min.: 10.55785, OUT3 Max.: 2.34560, Min.: 2.45670, OUT4 Max.: 0.34560, Min. 0.23455)