Janfire NH Installation And Servicing Instructions

Text of the manual

Janfire NH Burner Service Installation Manual 3.31.09 - Technical specifications are subject to change without prior

notice. 1(38) Installation and Servicing Instructions Janfire NH/Integral Pellets Burner with External Auger For heating contractors. Please read carefully prior to installation and servicing. Due to constant development, Janfire AB reserves t

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 2(38) Contents 1 Safety Instructions 3 1.1 General Information 3 1.2 Conventions 3 1.3 Safety Instructions for Installation and Service 4 1.4 Safety Systems 4 1.5 Compliance Declarations 4 2 Technical Data 5 3 Operational Description 6

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 3(38) 1 Safety Instructions 1.1 General Information Read the safety instructions carefully before installation. Always follow the safety instructions during installation and during maintenance. Follow the safety instructions on the war

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 4(38) 1.3 Safety Instructions for Installation and Service All electrical installation and service should be carried out by qualified personnel and in accordance to local electrical standards and codes. All plumbing and piping connecti

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 5(38) 2 Technical Data Janfire NH Pellet Burner Burner output capacity 10,000 – 78,000 Btu/hr (3 – 23 kW) Maintenance output 2,000 Btu/hr (600 W) Burner power consumption 80 W, 120 V AC, 60 Hz Automatic ignition coil 1100 W Pellet

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 6(38) 3 Operational Description An external auger feeds pellets from an external storage bin to a receptacle located in the top of the burner (internal hopper). An internal dosage auger then feeds the pellets to a drop shaft where they

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 7(38) The regulator works with three factors: P – Proportional power to temperature difference I – Integrating power over time due to temperature difference D – Differential power, due to rapid changes in temperature For P and I

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 8(38) The modulation power is used to achieve longer working periods, minimizing the number of starts and stops. The settings should be made so that the burner rapidly reaches target water temperature, and so that burner power will be

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 9(38) Fitting Instructions for Outdoor temperature sensor Location: If the rooms which temperature is to be regulated all face the same direction (same cardinal point) the temperature sensor has to be placed on that side. In any other

Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior

notice. 10(38) Pellet boiler and NH pellet burner system complete with fill auger and pellet storage. Figure 5. Function description

Other Burner Manuals