Hayward ECLI15MA Installation Instructions Manual
| Brand: | Hayward |
| Category: | Heat Pump |
| Model: | ECLI15MA (Installation Instructions Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 38 |
Text of Hayward ECLI15MA Installation Instructions Manual
Hayward ECLI15MA 2. Technical Specifications
4
2.1 Heat pump technical data
4
2.2 Operating range
5
2.3 Dimensions
6
3. INSTALLATION AND CONNECTION
7
3.1 Functional Diagram
7
3.2 Heat pump unit
7
3.3 Hydraulic connection
8
3.4 Electrical connection
9
3.5 Initial start-up
10
3.6 Water flow setting
12
4. USER INTERFACE
13
4.1 General presentation
13
4.2 Timer function settings
15
4.3 Setting the On/Off timers
16
4.4 Adjust setpoint
18
4.5 Locking and unlocki
Hayward ECLI15MA Thank you for purchasing the Hayward heat pump for swimming pools. The
Hayward FULL INVERTER heat pump has been designed to strict manufacturing
standards meeting the highest levels of quality required.
Hayward heat pumps offer you exceptional performance throughout your bathing
season by adapting wattage, power usage and noise levels to the heating
requirements of your swimming pool thanks to FULL INVERTER control logic.
Read the instructions
This device contains R32.
Never use a refrigerant other than R32. Any other gaseous body
mixed with R32 could cause abnormally high pressure and lead
to a failure or pipes bursting and injuring people.
When carrying out repairs or maintenance work, never use
copper tubes less than 0.8 mm thick.
As the heat pump is pressurized, never pierce the pipes or
attempt any brazing. There is a risk of explosion.
Never expose the device to flam
Hayward ECLI15MA Connect and properly tighten the power cable. A loose connection could
damage electrical components.
•
Exposing the heat pump to water or a humid atmosphere could cause
electrocution. Be very careful.
•
If you detect a fault or any abnormal situation, do not install the heat pump and
contact your dealer immediately.
•
All maintenance work should be done at the recommended intervals, as
specified in this manual.
•
Repairs must be carried out b
2.1 Heat pump technical data
Models
CLASSIC
FULL INVERTER
ECLI15MA(*)
ECLI20MA(*)
ECLI30MA(*)
ECLI40MA(*)
Supply voltage
V
220V-240V /1ph/50Hz
Refrigerant
/
R32
Load
kg
0.350
0.430
0.480
0.650
Mass in teqCO2
/
0.24
0.29
0.32
0.44
Leak check frequency
/
No specific frequency, but an annual check is recommended
Min--Max heating capacity (a)
kW
1.62--7.33
2.18--8.97
1.97--11.66
2.85--17.06
Min--Max electric input power(a)
kW
0
2. TECHNICAL SPECIFICATIONS (continued)
2.2 Operating range
Use the swimming pool heat pump unit within the following ranges of
temperature and humidity to ensure safe and efficient operation.
Heating mode
Cooling mode
Outside temperature
-7°C – +35°C
+7°C – +43°C
Water temperature
+12°C – +32°C
+8°C – +40°C
Relative humidity
< 80%
< 80%
Setting range from the set point
+15°C – +32°C
+8°C – +32°C
If the temperature or humidity doe
2. TECHNICAL SPECIFICATIONS (continued) 2.3 Dimensions
Models:
ECLI15MA / ECLI20MA / ECLI30MA*
A
C
D
E
B
A
F
G
C
D
E
B
Water inlet Ø 50 mm
Water outlet Ø 50 mm
Water outlet Ø 50 mm
Unit: mm
Type(*)
Size
ECLI15MA / ECLI20MA / ECLI30MA
ECLI40MA
A
956
1002
B
360
415
C
605
767
D
350
350
E
98
101
F
545
615
G
380
442
Water inlet Ø 50 mm
ECLI40MA*
(*) Check the machine references on the conversion table (see label on the cover of the manual).
Hayward ECLI15MA Place the heat pump outdoors and away from any enclosed technical
space.
Placed under a shelter, the minimum required distances mentioned
below must be respected in order to avoid any risk of air recirculation
and a deficiency in the unit's overall performance.
3. INSTALLATION AND CONNECTION
3.1 Functional Diagram
Pool
Water outlet
Chlorinator cell
(or other treatment)
Pump
filtration
Filter
Water Inlet
valve
Water outlet
valve
By-pass
valve
Note : The s
3. INSTALLATION AND CONNECTION (continued)
3.3 Hydraulic connection
The unit is supplied with two 50 mm Ø union connections. Connect the water
inlet to the heat pump coming from the filtration group then connect the water
outlet to the heat pump at the water conduit going to the pool (see diagram
below).
Install a by-pass valve between the heat pump entrance and exit.
It is advised to install the unit on a dissociated cement block or a
mounting bracket
Verify that the available electrical power supply and the network
frequency correspond to the required operating current taking into
account the appliance's specific location, and the current required to
supply any other appliance connected to the same circuit.
ECLI15MA / ECLI20MA / ECLI30MA / ECLI40MA(*)
230V +/- 10 % 50 Hz 1 Phase
See the corresponding wiring diagram in the appendix.
The connection box is located on the right side of the unit. Thre
Start-up procedure - After installation is complete, follow these steps:
1) Rotate the fans by hand to verify that they can turn freely by hand, and
that the turbine is correctly affixed to the motor shaft.
2) Ensure that the unit is connected correctly to the main power supply (see
the wiring diagram in the appendix).
3) Activate the filtration pump.
4) Verify that all water valves are open and that the water flows toward the
u
Hayward Heat Pump Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
HP55TR |
Hayward HP55TR User Guide (Installation instructions manual), @J4F8C4 |
44 | 652 | 137 | 16-07-2026 | |
SUPREME HP60TR |
#Z2FTY1: SUPREME HP60TR Heat Pump Installation instructions manual |
52 | 221 | 47 | 03-06-2026 | |
POWERLINE 15-81500 |
Hayward Heat Pump Installation instructions manual (File: PDF, 10-09-2026) |
163 | 1031 | 248 | 10-09-2026 | |
ECLI15MA |
ECLI15MA (Heat Pump ePDF User Guide, #X18V44) |
38 | 1324 | 226 | 15-04-2026 | |
HP50A1 |
HP50A1 (Heat Pump ePDF Manual, #2H484G) |
28 | 1268 | 191 | 28-08-2026 |