Hayward ECLI15MA 2. Technical Specifications

4 2.1 Heat pump technical data 4 2.2 Operating range 5 2.3 Dimensions 6 3. INSTALLATION AND CONNECTION 7 3.1 Functional Diagram 7 3.2 Heat pump unit 7 3.3 Hydraulic connection 8 3.4 Electrical connection 9 3.5 Initial start-up 10 3.6 Water flow setting 12 4. USER INTERFACE 13 4.1 General presentation 13 4.2 Timer function settings 15 4.3 Setting the On/Off timers 16 4.4 Adjust setpoint 18 4.5 Locking and unlocki

Hayward ECLI15MA Thank you for purchasing the Hayward heat pump for swimming pools. The

Hayward FULL INVERTER heat pump has been designed to strict manufacturing standards meeting the highest levels of quality required. Hayward heat pumps offer you exceptional performance throughout your bathing season by adapting wattage, power usage and noise levels to the heating requirements of your swimming pool thanks to FULL INVERTER control logic. Read the instructions

This device contains R32.

Never use a refrigerant other than R32. Any other gaseous body mixed with R32 could cause abnormally high pressure and lead to a failure or pipes bursting and injuring people. When carrying out repairs or maintenance work, never use copper tubes less than 0.8 mm thick. As the heat pump is pressurized, never pierce the pipes or attempt any brazing. There is a risk of explosion. Never expose the device to flam

Hayward ECLI15MA Connect and properly tighten the power cable. A loose connection could

damage electrical components. • Exposing the heat pump to water or a humid atmosphere could cause electrocution. Be very careful. • If you detect a fault or any abnormal situation, do not install the heat pump and contact your dealer immediately. • All maintenance work should be done at the recommended intervals, as specified in this manual. • Repairs must be carried out b

2.1 Heat pump technical data

Models CLASSIC FULL INVERTER ECLI15MA(*) ECLI20MA(*) ECLI30MA(*) ECLI40MA(*) Supply voltage V 220V-240V /1ph/50Hz Refrigerant / R32 Load kg 0.350 0.430 0.480 0.650 Mass in teqCO2 / 0.24 0.29 0.32 0.44 Leak check frequency / No specific frequency, but an annual check is recommended Min--Max heating capacity (a) kW 1.62--7.33 2.18--8.97 1.97--11.66 2.85--17.06 Min--Max electric input power(a) kW 0

2. TECHNICAL SPECIFICATIONS (continued)

2.2 Operating range Use the swimming pool heat pump unit within the following ranges of temperature and humidity to ensure safe and efficient operation. Heating mode Cooling mode Outside temperature -7°C – +35°C +7°C – +43°C Water temperature +12°C – +32°C +8°C – +40°C Relative humidity < 80% < 80% Setting range from the set point +15°C – +32°C +8°C – +32°C If the temperature or humidity doe
2. TECHNICAL SPECIFICATIONS (continued) 2.3 Dimensions Models: ECLI15MA / ECLI20MA / ECLI30MA* A C D E B A F G C D E B Water inlet Ø 50 mm Water outlet Ø 50 mm Water outlet Ø 50 mm Unit: mm Type(*) Size ECLI15MA / ECLI20MA / ECLI30MA ECLI40MA A 956 1002 B 360 415 C 605 767 D 350 350 E 98 101 F 545 615 G 380 442 Water inlet Ø 50 mm ECLI40MA* (*) Check the machine references on the conversion table (see label on the cover of the manual).

Hayward ECLI15MA Place the heat pump outdoors and away from any enclosed technical

space. Placed under a shelter, the minimum required distances mentioned below must be respected in order to avoid any risk of air recirculation and a deficiency in the unit's overall performance. 3. INSTALLATION AND CONNECTION 3.1 Functional Diagram Pool Water outlet Chlorinator cell (or other treatment) Pump filtration Filter Water Inlet valve Water outlet valve By-pass valve Note : The s

3. INSTALLATION AND CONNECTION (continued)

3.3 Hydraulic connection The unit is supplied with two 50 mm Ø union connections. Connect the water inlet to the heat pump coming from the filtration group then connect the water outlet to the heat pump at the water conduit going to the pool (see diagram below). Install a by-pass valve between the heat pump entrance and exit. It is advised to install the unit on a dissociated cement block or a mounting bracket

Verify that the available electrical power supply and the network

frequency correspond to the required operating current taking into account the appliance's specific location, and the current required to supply any other appliance connected to the same circuit. ECLI15MA / ECLI20MA / ECLI30MA / ECLI40MA(*) 230V  +/- 10 % 50 Hz 1 Phase See the corresponding wiring diagram in the appendix. The connection box is located on the right side of the unit. Thre

Start-up procedure - After installation is complete, follow these steps:

1) Rotate the fans by hand to verify that they can turn freely by hand, and that the turbine is correctly affixed to the motor shaft. 2) Ensure that the unit is connected correctly to the main power supply (see the wiring diagram in the appendix). 3) Activate the filtration pump. 4) Verify that all water valves are open and that the water flows toward the u

Hayward Heat Pump Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
HP55TR

Hayward HP55TR User Guide (Installation instructions manual), @J4F8C4

44 652 137 16-07-2026
SUPREME HP60TR

#Z2FTY1: SUPREME HP60TR Heat Pump Installation instructions manual

52 221 47 03-06-2026
POWERLINE 15-81500

Hayward Heat Pump Installation instructions manual (File: PDF, 10-09-2026)

163 1031 248 10-09-2026
ECLI15MA

ECLI15MA (Heat Pump ePDF User Guide, #X18V44)

38 1324 226 15-04-2026
HP50A1

HP50A1 (Heat Pump ePDF Manual, #2H484G)

28 1268 191 28-08-2026

Heat Pump: Similar Manuals