Framery O Troubleshooting Instructions
Read Online
Read the Framery O Troubleshooting Instructions online using the built-in PDF viewer.
Key Pages of Document
2 The door is leaking sound or does not seal properly..............................7 3 The body covers do not fit.......................................................................23 4 Power issues..............................................................................................26 4.1 There is no electricity in the ...
of the pod. It is important that these instructions are followed to recognize and prevent potential risks before they occur. Note: All personnel must understand and observe these instructions prior to installation or maintenance of the pod. Restrictions • Non-conventional use • Installation or maintenance of the pod without reading and understanding the ...
• Ambient temperature: +15°C ... +30°C (59°F ... 86°F) • Humidity: max. 50% 6 Framery O VCR Troubleshooting instructions [email protected] ...
Condition When you are standing outside the pod you can hear what a person inside the pod is saying and the person inside the pod can hear noises from outside the pod. Cause: The door is too low. The door is not vertically in the middle of the door opening. Solution: Adjust the door height. 1. Remove the caps from the hinges. Framery O VCR Troubleshooting instructions [email protected] 7 ...
3. Close the door. 4. To raise the door, insert the hex key into the top of the upper hinge and turn clockwise. To lower the door, turn counter-clockwise. Note: After the initial installation, the door normally does not have to be lowered, but raised. 8 Framery O VCR Troubleshooting instructions [email protected] ...
is the same. Turn clockwise to raise and counter-clockwise to lower the setting. 6. Make sure that the door is aligned correctly. 7. Test with a flashlight from the inside of the pod. If the flashlight shines through the door seams, adjust the door. 8. Repeat steps 4–6 if needed. 9. Close the door. Framery O VCR Troubleshooting instructions [email protected] ...
Note: Make sure that both hinges have the same height setting. 11. Install the caps. Cause: The floor of the pod is not leveled. Solution: Level the floor. 1. Pull the carpet out from under the wall felts and remove (the carpet) from the pod. 10 Framery O VCR Troubleshooting instructions [email protected] ...
• Along the sides • At the edge of the floor module (on the ABS strips) Framery O VCR Troubleshooting instructions [email protected] 11 ...
gradually. 5. Reinstall the carpet. Note: Make sure that the carpet is firmly in place and that there are no bumps. 12 Framery O VCR Troubleshooting instructions [email protected] ...
Solution: Straighten the pod. 1. Check the straightness of the pod with a spirit level on both sides. If the pod is not standing straight, complete the following steps. 2. Remove the wall body covers. Framery O VCR Troubleshooting instructions [email protected] 13 ...
4. Pull the carpet out from under the wall felts and remove (the carpet) from the pod. 14 Framery O VCR Troubleshooting instructions [email protected] ...
6. Unscrew the 4x30 screws (32 pcs) and remove the top and bottom cover panels (4 pcs). Framery O VCR Troubleshooting instructions [email protected] 15 ...
8. Unscrew the 4x30 screws (4 pcs) and remove the roof cover panels (2 pcs). 16 Framery O VCR Troubleshooting instructions [email protected] ...
10. Open the door completely (180°). Framery O VCR Troubleshooting instructions [email protected] 17 ...
12. Measure and push the pod walls as needed and, keeping them straight, tighten the bolts at the same time. Note: Do not overtighten the bolts. 18 Framery O VCR Troubleshooting instructions [email protected] ...
14. Reinstall the removed parts. Cause: The door is sagging. Solution: Install an adjustment plate under the lower hinges. 1. Open the door completely (180°). Framery O VCR Troubleshooting instructions [email protected] 19 ...
3. Unscrew the 5x30 screws (4 pcs) and remove the lower hinges. 20 Framery O VCR Troubleshooting instructions [email protected] ...