FMS RTM X42.CC Operating Manual

Text of FMS RTM X42.CC Operating Manual

RTM X42.CC Control Center with

RTM Monitoring & Control Software System extension for Telemetry System RTM X42 Document version 1.31 Published / Author 03/2019 / NS Software Version 1.30 Diese Bedienungsanleitung ist auch in Deutsch erhältlich. Bitte nehmen Sie Kontakt mit Ihrer FMS Vertretung auf. © by FMS Force Measuring Systems AG, CH-8154 Oberglatt — All rights reserved.

Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software

19.03.2019 2 1 Table of Contents 1 TABLE OF CONTENTS ............................................................................................................................. 2 2 SAFETY INSTRUCTIONS .......................................................................................................................... 4 2.1 Presentation of the safety instructions ..........
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 3 7.1.9 Actual value of the braking force in the brake actuator ............................................................... 40 7.1.10 Braking force in the brake actuator as a graphic display ........................................................ 40 7.1.11 Status indication of the brake actuation ....................................................................
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 4 2 Safety instructions All safety instructions, operating and installation instructions listed are designed to ensure the correct operation of the device. In any case, they must be always observed to ensure the safe operation of the systems. Failure to comply with the safety instructions and the use of the devices beyond their specified performance data may endanger t
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 5 This device complies with the FCC rules Part 15, as well as the approved RSS standard(s) issued by Canada. The operation is subject to the following two conditions: - This device may not cause harmful interference; and - This device must accept any received interference, including interferences which are liable of causing undesirable operation Information on radio fr
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 6 3 Product information 3.1 System Requirements The telemetry system RTM X42 is required to measure the strand tension to use the RTM X42.CC Control Center. 3.2 Functional description The RTM X42.CC Control Center is a central computer unit. It manages and controls all measurement results, as well as the corresponding control parameters of the RTM X42 telemetry system.
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 7 3.4 Main components Figure 1: Main Components RTM X42.CC RTM_X42_Modbus_BA_Manual.ai Designation of the main components Position Description Position 2 System Extension RTM X42.CC Control Center 2a RTM X42.CC Control Center Central computer unit with pre-installed RTM Monitoring & Control software o. Fig. Monitor, keyboard and mouse, connection cable, etc. Table 1: M
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 8 4 Connections on the main computer Figure 2: Main computer ports RTM_X42_Modbus_BA_Manual.ai Ports Position Description 1 Power supply unit, mains adapter included in the scope of supply 2 USB ports For keyboard, mouse, data transfer via USB flash-drive (remove USP stick after use) 3 HDMI connector For the monitor
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 9 Ports Position Description 4 Network connection 2 “NET” Connect this port to your corporate or machine network. The IP address is automatically obtained from the network (DHCP). 5 Network port 1 “RTM” Connect this port to the switch to which the components of the RTM X42 system are connected. This connector may only be used for communication with the componen
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 10 5 Basic Configuration — Start-Up 5.1 Delivered condition The system is pre-configured at the factory and adjusted to the installed components. Telemetry System RTM X42 - The IP address of the EMGZ482R.Modbus reception module 192.168.0.090 - Unique radio channel and ID per receiver module - Number of Expansion Modules System Extension RTM X42.CC Control Center - IP
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 11 Figure 3 : Desktop, top left network icon, network settings Figure 4 : Network settings, network
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 12 Figure 5: Ethernet adapter 1 for control center and RTM X42 components; ethernet adapter 2 for corporate network Figure 6: Ethernet adapter 1, details, hardware address = MAC Address The MAC address can be copied to the RTM Monitoring & Control software via copy & paste.
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 13 5.4 Software modules Depending on the scope of supply, you will receive different software modules, refer to Software modules p. 69ff. This Operating Manual covers the functions of all available modules. Depending on the scope of the order, you may only have limited functionality if not all software modules have been activated.
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 14 6 Software interface 6.1 Launch of the FMS Monitoring & Control Software The FMS Monitoring & Control software can be started on all computers on which a browser is installed. The RTM X42.CC Control Center must be connected to the corporate network. In the central computer unit, proceed as follows: - Start the central computer unit - Log on with user “RTM” and t
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 15 6.2 Login Figure 7: Login screen After the start, the basic screen appears with information related to the software version and function. To log in, click on “Login”. On the first time you sign in, use Login: Administrator Password: rtm1
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 16 6.3 Home Screen overview Full-screen mode To view the browser in full-screen mode, press F11. This will help you improve the display. To exit full-screen mode, press F11 again. Tooltips If you hover over controls or input fields, you get hints related to the function or input. Figure 8: Tooltip - HOME
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 17 Figure 9: Home-screen overview Surface Position Description 1 Bar graph display of channels and channel groups 2 Histogram 3 Main navigation 4 Device status and status details 5 Data recording menu 6 Basic settings, user management 7 Loaded recipe and logged-in user 8 Software version Table 3: Overview start screen "Home" 1 2 4 7 6 5 8 3
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 18 6.4 Basic settings 6.4.1 Global settings Figure 10: Basic settings - Global settings You can display or hide page navigation by pressing “>” or “<”. Basic setting — Global settings Position Description 1 Page navigation 2 Global settings Language — Setting the interface language (German or English) Force unit — Newton (N) or Pound force (lbf) Length un
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 19 6.4.2 Plant Settings - System settings - Strander Figure 11: Basic setting - System settings - Strander These settings refer to specific settings of the strander. You can assign a name for the plant here. It will be used, for example, when creating quality protocols. At this point, you can also enter the name and number of the lay-plate(s). To add a new one, click t
Operating Manual RTM X42.CC Control Center, RTM Monitoring & Control Software 19.03.2019 20 Basic setting — Global settings Position Description 1 Table “RTM Receiver/Extension Modules and Force Sensors” Name Enter a unique name Caption Here you can enter your own label for the component. E.g., a line of the nameplate or its own name. This information will not be used otherwise. Lay-plate Select the pulley on which the receiver module is located. IPv

FMS Control Systems Owners Instructions: