Text of visual engineering MFR 4K Operation & User’s Manual
Video solutions. Integrated
visualengineering.co.uk
Page 1
MFR 4K
User Guide for the
MFR 4K PTZ Camera
Video solutions. Integrated visualengineering.co.uk
Page 2
Change History���������������������������������������������������������������������������������������������������������������������
Video solutions. Integrated visualengineering.co.uk
Page 3
Change History
Warranty and Support
All Visual Engineering products are supplied as standard with a 12 month ‘Return to Base’ warranty.
Please note: Any unauthorised product disassembly, modification or the removal of tamper
proof labels will void the warranty.
In the event of a suspected product failure, users should contact the Visual Engineering support
t
Video solutions. Integrated visualengineering.co.uk
Page 4
Introduction
The MFR 4K is a very rugged PTZ camera environmentally sealed for use in harsh environments.
It incorporates a camera with a 4x Full HD resolution and a 20x optical zoom lens supporting a 70°
wide angle of view.
It is capable of outputting Quad Full HD, Full HD or lower video resolutions via a water proof HDMI
connector.
To ensure it retains perfor
Video solutions. Integrated visualengineering.co.uk
Page 5
Connections
The MFR 4K kit includes a power comms break out cable, part number 110-3562.
The cable assembly connects to the Fischer MiniMax connector on the base of the camera.
All signals are then split out to their relevant connectors.
The connections are described below.
Connector
Signal
BNC
Unused
Connector
Signal
Micro USB
Comms
EXT 232
232 Comms
DC Coax
Po
Video solutions. Integrated visualengineering.co.uk
Page 6
Power Comms
Cable connector.
HDMI
weatherproof
connector.
On Screen Display
On start up the
OSD video overlay
reports the
camera’s current:
Temperature
Humidity
Dew Point
This information
can be used
to monitor the
performance of
the camera and its
hermetic seal.
The camera features a purge port which is
used to purge the camera with either dry air
or nitrogen
Video solutions. Integrated visualengineering.co.uk
Page 7
Sub-Zero Start Up
If the MFR 4K camera is powered on at temperatures below -15°C the primary and secondary
heaters will both be enabled.
The camera will remain powered down until the internal temperature rises above -15°C
Once the internal temperature rises above -15°C the camera will start up, the primary heater will
turn off, keeping only the secondary heat
Video solutions. Integrated visualengineering.co.uk
Page 8
Configuring the Camera
The MFR 4K can be configured for a specific user profile, to include; communications settings,
motor control and video format. Once configured the camera will retain the settings.
The camera is configured using a menu structure on its control interface which is only accessible
at power on. To access the control menu it is necessary to conn
Video solutions. Integrated visualengineering.co.uk
Page 9
Motor Options
Motor Options
Sub Menu
Description
Options
Auto Position
Correction
Whether the camera automatically corrects
its actual position if external forces
act upon it
Disabled, Enabled
Stall Detection
Detects a stall in the motor drive
Disabled, Enabled
Motor Speed
The speed at which the motors are driven
High, Medium, Low
Hold Torque
The torque force wh
Video solutions. Integrated visualengineering.co.uk
Page 10
Software Control
The MFR 4K camera’s serial communication supports PelcoD, PelcoP & Sony Visca protocols.
The user may choose to use a software controller of their choice or use the VE Camera Controller.
This software application can be downloaded from the Visual Engineering website:
www.visualengineering.co.uk/supportdownload/9
The user should install the So
Video solutions. Integrated visualengineering.co.uk
Page 11
It is necessary to connect the camera to a USB port on the PC. The operating system of the
computer will allocate this a COM port number. Once this connection has been made the user can
go ahead and connect the application to the COM port. In the example below the port COM3 has
been selected. Now select Connect.
Now that the software application is connected to
visual engineering Security Camera Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
SWZ HD |
Security Camera #63H497 |
25 | 778 | 195 | 24-05-2026 | |
MKIIID |
PDF Manual (@3X21A3), visual engineering MKIIID Security Camera (14-08-2026) |
30 | 991 | 179 | 14-08-2026 | |
PAL/NTSC H.264 Encoder |
PAL/NTSC H.264 Encoder (Security Camera ePDF User Manual, #IA1NP9) |
43 | 1280 | 192 | 08-07-2026 | |
BWC |
Security Camera #61J6K2 |
27 | 1485 | 327 | 04-06-2026 | |
SWZ |
visual engineering SWZ User Manual (Operation & user’s manual), @GQW3JN |
13 | 68 | 11 | 02-08-2026 | |
MFR |
#1MGNOW: MFR Security Camera Operation & user’s manual |
31 | 302 | 70 | 14-08-2026 | |
surveillance camera |
surveillance camera Operation & user’s manual - 97I854 |
29 | 3.59 Mb | 1232 | 308 | 06-09-2026 |
V DMH |
visual engineering Security Camera Operation & user’s manual (File: PDF, 25-06-2026) |
10 | 1251 | 263 | 25-06-2026 | |
MFR 4K |
#7F9F4R: MFR 4K Security Camera Operation & user’s manual |
13 | 591 | 107 | 16-08-2026 |